SOLICITATION NOTICE
Z -- INSTALLATION OF SPRINKLERS
- Notice Date
- 12/12/2005
- Notice Type
- Solicitation Notice
- Contracting Office
- ACA, Fort Campbell, Directorate of Contracting, Building 2174, 13 ? & Indiana Streets, Fort Campbell, KY 42223-1100
- ZIP Code
- 42223-1100
- Solicitation Number
- W91248-06-Q-0010
- Response Due
- 1/17/2006
- Archive Date
- 3/18/2006
- Small Business Set-Aside
- N/A
- Description
- Requirement is to provide documents for the modifications of buildings and to install a complete working wet pipe sprinkler system suitable to adequately protect the caged working area in the hanger bay of buildings 7262 and 6635. The sprinkler sh all be designed and installed in accordance with the National Fire Protection (NFPA) 12, Installation of Sprinklers, UFC3-600-1, Jan 2004, NFPA 409, Aircraft Hangers, Wet Pipe Sprinkler Systems and Fire Alarm Systems. The new wet pipe system shall have a flow switch connected to the existing fire alarm control panel. The new pipe also shall be hydraulically calculated to provide the appropriate GPM/SF for the caged area. The contractor shall make all required modifications to have a complete operating s ystem. The sprinkler system design shall meet the same hazard design as the existing hangar bay sprinklers. Contractor shall install water line from fire main to include tapping valve and sleeve (16 maximum) mechanical joint gate valve, and valve box for fire suppression water distribution. Water line shall be excavated, installed, back-filled and disinfected in accordance with plans and specifications. The water supply for building 7262 is via the existing delunge pumping station, building 7284. T he pumps each have a capacity of 1500GPM. Static pressure in underground sprinkler supply main is approximately 75 psi. The water supply for building 6635 will be via existing delunge pumping station: building 6623 pumps have a capacity of 1500GPM each. Static pressure in underground sprinkler supply main is approximately 100 psi. The contractor shall furnish and install a fire alarm panel, and design and install a fire alarm system. The contractor shall install a Government furnished King Fisher trans mitter, antenna and batteries. Contractor is to provide all materials necessary to install IAW manufacturers installation and instructions and provided drawings. The Contractor is responsible for knowledge of and compliance with all environmental laws, regulations, and programs of this installation. For the purpose of determining Small Business size for this acquisition is NAICS 238220, the average annual receipts of a concern and its affiliates for the preceding three fiscal years must not exceed $12 million. The Estimated Price Range is Between $25,000.00 and $100,000.00. The Solicitation packages downloaded from Directorate of Contracating Home Page utilizing the Adobe Portable Document Format (PDF). You may obtain a free copy of the Adobe Acrob at Reader to print and view the solicitation at www.adobe.com/prodindex/acrobat/readstep/html. This solicitation will be available on or about 28 December 2005 on the Directorate of Contracting Home Page http://doc.campbell.army.mil. For further info rmation on obtaining the solicitation contact Contract Specialist Liz Hill, (270) 798-7832. All responsible sources may submit a quote, which shall be considered by this Agency. This project is subject to the availability of funds.
- Place of Performance
- Address: ACA, Fort Campbell Directorate of Contracting, Building 2176, 13 1/2 & Indiana Streets Fort Campbell KY
- Zip Code: 42223-5334
- Country: US
- Zip Code: 42223-5334
- Record
- SN00950317-W 20051214/051212212137 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |