SOLICITATION NOTICE

12 -- Sprinkler System

Notice Date
11/7/2005
 
Notice Type
Solicitation Notice
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
Department of Justice, Bureau of Prisons, FPC Maxwell Air Force Base, Maxwell Air Force Base, Montgomery, AL, 36112
 
ZIP Code
36112
 
Solicitation Number
31101-0007-6
 
Response Due
11/18/2005
 
Point of Contact
KaCheryl Bibb, Contract Specialist, Phone 334-293-2133, Fax 334-293-2325, - KaCheryl Bibb, Contract Specialist, Phone 334-293-2133, Fax 334-293-2325,
 
E-Mail Address
kbibb@bop.gov, kbibb@bop.gov
 
Description
"Faith-Based and Community-Based Organizations have the right to submit offers/bids equally with other organizaions for contracts for which they are eligible. Re: Building 1249 is not equipped with a fire protection sprinkler system. A. Subject: Install Fire Protection Sprinkler System in Bldg 1249 B. Place of Performance: Federal Prison Camp, Montgomery, AL, Bldg 1249. The contractor will sign the consultant log indicating the date and time of arrival and departure from the institution. C. Schedule: A briefing will be conducted with all contractors, and subcontractors, to advise them of institutional security procedures. These procedures will be adhered to at all times. Contractor will be allowed to work between the hours of 7:30 a.m. until 3:30 p.m., Monday through Friday excluding Federal Holidays D. General: Provide a wet type sprinkler system to meet ALL Local, State and Federal requirements in building 1249 located at the Federal Prison Camp, Maxwell Air Force Base. The Government will provide drawings to be used to determine the building width, length, etc. These drawings are schematic and diagrammatic in nature only. They are not to be used for construction / erection. These drawings do not show all required bends, offsets, valves and miscellaneous fittings for a complete installation. The contractor shall show all required data as required per NFPA guidelines. The Contractor will visit the site and view existing conditions prior to submitting a bid and commencing any work. The Contractor will be responsible for verification of all existing utility locations. The Contractor will be responsible for verification of all existing domestic water line, sprinkler system, etc.. Where connecting to a utility service, Contractor will verify location, ,size, materials, fluid being handled and inverts of all existing utilities. Contractor will confirm that new pipes being routed to existing utilities can be installed conforming to all codes and as specified. The Contractor shall notify the Government of any conflicts and / or discrepancies prior to purchasing any materials or performing any work, extension of work or connection, with the exception of excavation or other work to provide access to the concealed utility. The Government will be responsible for the removal and disposal of all ceiling finish material as necessary to accommodate installation of sprinkler systems. The systems will include all piping, valves, heads, etc., as required in a “correctional” environment, necessary to insure fully functional systems at completion of work. The Contractor will not hang or support any piping from other pipes, ducts, equipment or cables and conduit. The Contractor shall paint all above grade piping, fittings, etc.. The Contractor shall verify that the city water system shall be capable of delivering adequate water supplies for the hydraulically designed sprinkler systems. If this cannot be supplied, then additional water supplies will be necessary. The Contractor will provide up to date water pressure data per NFPA guidelines before work is started. The Contractor shall coordinate installation of sprinkler NOTE: THIS NOTICE MAY HAVE POSTED ON FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (07-NOV-2005). IT ACTUALLY APPEARED OR REAPPEARED ON THE FEDBIZOPPS SYSTEM ON 16-DEC-2005, BUT REAPPEARED IN THE FTP FEED FOR THIS POSTING DATE. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link to FedBizOpps document.
(http://www.fbo.gov/spg/DOJ/BPR/31101/31101-0007-6/listing.html)
 
Place of Performance
Address: Federal Prison Camp, Bldg 1249 Maxwell AFB Montgomery,AL
Zip Code: 36112
Country: U.S.
 
Record
SN00954132-F 20051218/051216214310 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.