SOLICITATION NOTICE
66 -- Rib Air Test Gauge Assembly and Gauge, Differential, Pressure (2)
- Notice Date
- 1/18/2006
- Notice Type
- Solicitation Notice
- NAICS
- 332912
— Fluid Power Valve and Hose Fitting Manufacturing
- Contracting Office
- TACOM - Rock Island, ATTN: AMSTA-AQ-AR, Rock Island Arsenal, Rock Island, IL 61299-7630
- ZIP Code
- 61299-7630
- Solicitation Number
- W52H09-06-R-0043
- Response Due
- 3/3/2006
- Archive Date
- 5/2/2006
- Small Business Set-Aside
- Total Small Business
- Description
- Requirements are issued as a 100% Small Business Set-Aside solicitation for three items to be awarded as a Firm Fixed Price contract with options. The three items to be procured are part of the Chemical Biological Protective Shelter (CBPS). The Ch emical Biological Protective Shelter (CBPS) is a highly mobile, contamination free, environmentally controlled work area for forward deployed Medical Treatment teams/squads. CLIN 0001: Rib Air Test Gauge Assembly, NSN: 6685-01-502-7538, P/N 17-2-0900-1, quantity of 43 each with (2) 100% option periods. Subject assembly is a special tool that is used in setting/adjusting the CBPS Environmental Control Unit rib air fan pressure to a reading 4.2 pounds per square inch (PSI). The gauge portion of the assemb ly has a 2.5 inch diameter dial size with a 0-5 PSI pressure range. The assembly also includes pipe nipple, hose barb, ball valve, pipe sealant and hose clamp components. First Article Test is not required. CLIN 0002: Gauge, Differential, Pressure, N SN: 6685-01-497-5072, P/N 17-1-5755-1, quantity of 16 each with (2) 100% option periods. The gauge will have a pressure range of 0 to 3.0 PSI and max pressure of 25 PSIG. Accuracy is +/- 2% of full range. Unit must be either flush mounted in a 4 13/16 inch opening or surface mounted. High and low pressure limits - two photocells activated, SPDT relays actuated when master pointer crosses the high and low limit pointers. Single relay contact finish is gold plating over silver. A tamperproof knob with spanner key to change set points is required. Operating temperature range is -20F to 120F and operating voltage is 22 to 30 VDC. Maximum weight is 1.7 lbs. First Article Testing is required. CLIN 0003: Gauge, Differential, Pressure, NSN: 6685-01-4 97-5071, P/N 17-1-5754-1, quantity of 18 each with (2) 100% option periods. The gauge will have a pressure range of 0 to 1.0 inches of water and max pressure of 25 PSIG. Accuracy is +/- 2% of full range. Unit must be either flush mounted in a 4 13/16 i nch opening or surface mounted. Photocell activated, SPDT relays actuated when master pointer crosses the limit pointer. Single relay contact finish is gold plating over silver. A tamperproof knob with spanner key to change set points is required. Oper ating temperature range is -20F to 120F and operating voltage is 22 to 30 VDC. Maximum weight is 1.7 lbs. First Article Testing is required. FOB for all quantities is Destination. Estimated solicitation issue date is 02 February 2006. This solicitat ion incorporates a Technical Data Package (TDP) that cannot be provided via the Internet. Vendors can request same by submission of an email request to: tacom-ri-tdp@ria.army.mil. Any said requests should contain the following information; CAGE Code (if available), Company Name, Point of Contact (optional), Street Address, City, State, Zip Code, Telephone Number. A TDP will be provided by normal mail after the solicitation has been released to the Internet. This solicitation will be issued electronicall y in accordance with FAR 4.502 and 5.102, therefore, hardcopies will not be provided. Vendors wishing an electronic copy may download it on or after the issue date by accessing the following address via the Internet: https://aais.ria.army.mil/aais/SOLINFO /index.htm. CAUTION: This solicitation will be issued electronically as will any amendments thereto. It is therefore incumbent upon interested parties to periodically access the above Internet address in order to obtain any amendments that may be issued . Failure to obtain amendments and to respond to them before the date and time set for bid opening/receipt of proposals may render your bid or proposal nonresponsive and result in the rejection of it.
- Place of Performance
- Address: TACOM - Rock Island ATTN: AMSTA-LC-CBKB, Rock Island Arsenal Rock Island IL
- Zip Code: 61299-7630
- Country: US
- Zip Code: 61299-7630
- Record
- SN00968233-W 20060120/060118212405 (fbodaily.com)