SOLICITATION NOTICE
Z -- Replace Fire Alarm System in Building 2001
- Notice Date
- 2/13/2006
- Notice Type
- Solicitation Notice
- NAICS
- 238210
— Electrical Contractors
- Contracting Office
- Defense Logistics Agency, Logistics Operations, Defense Distribution Center, 2001 Mission Drive DDC CSS-A, Bldg 81, New Cumberland, PA, 17070-5001
- ZIP Code
- 17070-5001
- Solicitation Number
- SP3100-06-R-0013
- Archive Date
- 9/30/2006
- Description
- Contractor shall provide all supervision, labor, material and equipment necessary to replace the fire alarm system in Building 2001 at the Defense Distribution Depot Susquehanna (DDSP), New Cumberland, PA. The following summary of work is for the purpose of general information and is not intended to include and describe every feature or item or to define the scope of work. It is expected that the Contractor will attend the preproposal conference/site visit and thoroughly familiarize himself with the conditions. This work includes designing and providing a new analog/addressable fire alarm system as described herein and on the drawings for Building 2001. Specifications and drawings will be provided when the solicitation package is issued. 1. Remove two fire alarm control panels located at the security desk at the employee's entrance and the 10-transponder panels distributed throughout the building. 2. Reuse the existing underground conduit serving B-2003 and all valve supervisory switches on post indicating valves. Junction boxes for existing initiating devices shall be replaced. 3. Provide new conduit for all new conductors, unless otherwise noted. 4. Provide new system wiring/conductors. 5. Remove existing notification devices and associated wiring/conduit. 6. Provide new notification appliances, conduit, and wiring as required to meet NFPA 72 and ADA guidelines. 7. The system shall include wiring, raceways, pull boxes, terminal cabinets, outlet and mounting boxes, control equipment, alarm, and supervisory signal initiating devices, alarm notification appliances, and other accessories and miscellaneous items required for a complete operating system even though each item is not specifically mentioned or described. Provide systems complete and ready for operation. Equipment, materials, installation, workmanship, inspection, and testing shall be in strict accordance with the required and advisory provisions of NFPA 72, NFPA 70, and NFPA 90A except as modified herein. Each remote fire alarm control unit shall be powered from a wiring riser specifically for that use or from a local emergency power panel located on the same floor as the remote fire alarm control unit. Where remote fire control units are provided, equipment for notification appliances may be located in the remote fire alarm control units. Period of Performance: Contractor shall commence work upon receipt of the Notice to Proceed and shall complete the entire work ready for use within 300 calendar days after receipt of the Notice to Proceed. This acquisition is unrestricted pursuant to the Small Business Competitiveness Demonstration Program Act of 1988, Public Law 100-656 (15 U.S.C. 644 note). Contract award will be issued pursuant to the Small Business Competitiveness Demonstration Program. The estimated price range is between $1,000,000 and $5,000,000. The tentative timeframe for issuance of solicitation SP3100-06-R-0013 for the above stated requirement is the week of March 13, 2006. A Pre-Proposal Conference/Site Visit will be conducted. The exact date and time for the preproposal conference/site visit will be stated in the solicitation package. The solicitation will also establish the proposal due date and time. Access to the solicitation package to include the specifications and drawings will only be made available to prospective offerors via the Federal Business Opportunities (FedBizOpps) website at http://www.eps.gov. Hard copies of solicitation SP3100-06-R-0013 to include specifications and drawings will not be distributed. Prospective offerors are cautioned concerning their responsibility to access the website for any amendments that may be issued under the solicitation. There will be no advance notification of amendment issuance. Prospective offerors are advised to consult the website frequently to check for the issuance of amendments. Amendments may be issued up until the proposal due date. Failure to acknowledge amendments may render your proposal ineligible for award. To receive awards resulting from solicitations issued after May 31, 1998, your company must be registered in the DoD Central Contractor Registration (CCR) database. Contractor may obtain information on registration and annual confirmation requirements by calling 1-888-227-2423 or via the Internet at http://www.ccr.gov. Prospective contractors shall also complete electronic annual representations and certifications at http://orca.bpn.gov in conjunction with required registration in the Central Contractor Registration (CCR) database. All responsible sources may submit a proposal which shall be considered by this agency. The Government intends to award one contract as a result of this solicitation. Award will be made using the lowest priced technically acceptable source selection process. Proposals shall be evaluated for acceptability only and shall not be rated. The solicitation will detail the evaluation factors for award. An offeror must be determined responsible according to the standards of FAR Subpart 9 to be eligible for award.
- Place of Performance
- Address: Defense Distribution Depot Susquehanna (DDSP), 2001 Mission Drive, New Cumberland, PA
- Zip Code: 17070
- Country: USA
- Zip Code: 17070
- Record
- SN00986966-W 20060215/060213211602 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)