Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF FEBRUARY 15, 2006 FBO #1542
MODIFICATION

D -- Integrated Facility Security Service

Notice Date
2/13/2006
 
Notice Type
Modification
 
NAICS
561621 — Security Systems Services (except Locksmiths)
 
Contracting Office
Department of Justice, Justice Management Division, Procurement Services Staff (PSS), 1331 Pennsylvania Avenue, N.W. National Place Building, 10th Floor, Washington, DC, 20530
 
ZIP Code
20530
 
Solicitation Number
DOJAPG6G029
 
Response Due
2/22/2006
 
Archive Date
3/9/2006
 
Point of Contact
Miles Stroman, Contracting Officer, Phone (202) 307-1969, Fax (202) 307-1931,
 
E-Mail Address
miles.stroman@usdoj.gov
 
Small Business Set-Aside
Total Small Business
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. The solicitation number is DOJ-APG-6-G-029 and it is issued as a request for quotation (RFQ). The initial notice did not contain the list of items/schedule of requirements. Therefore, the combined synopsis/solicitation is hereby amended to provide the list of items required to configure the security system. 1 – LOT Drawings for Submittals, 1 - LOT Permit and Inspection Fee, 1 - LOT Sound Test for Permit Approval, 1 – LOT Submittals for Plan Review, 6 - 4360PL Wire 18/2C STR OAS PLENUM, 5 - 4510PL Wire 22/4C STR OAS PLENUM, 6 - 4530PL Wire 22/6C STR OAS PLENUM, 2 - 60990PL Wire Twinax RG59 with 18/2 PLENUM, 4 - 7004-159 BLP 206 Processor Less Enclosure, 1 - 7062-128 Axxess Express to Axxess NS Upgrade, 14 - 8300-184 iClass R10 Card Reader, 2 - 8300-185 iClass R40 Card Reader, 2 - AX-AL1012ULB Power Supply for RAMM and BLP Controllers, 2 - AX-AL600ULB Power Supply for Locks and Devices, 6 - AX-PD8 Fused Power Distribution Module, 14 - AX-RBST Interface Relay, 7 - DS-DS150i REX Motion Detector, 1 - MX-ASSET Asset Tracking Software Module, 1 - N1C14TKL Key Lock for Enclosure, 1 - N1C364809 NEMA I Enclosure 36x48x09, 1 - NP4836 Enclosure Backplane, 4 - PW-PS12550U 12V55AH Battery for 8 Hours Standby Minimum, 100 - SP8700-171-C1000 iClass Corp 1000 Access Cards, 50 - SP8700-180-C1000 iClass Corp 1000 Access Key Tag, 14 - SR-1078CBR Door Position Switch, 1 - 7003-705 RAMM Ethernet Adapter, 1 - 7062-CCTV-IV CCTV Monitor Software Module, 1 - AX-248175ULC UL Listed Camera Power Supply, 1 - CV-DUALMON Dual Monitor VGA Card, 1 - CV-LCD17 17" Dell LCD Monitor, 1 - CV-MON17 17" Dell VGA CRT Monitor, 1 - CV08D-0400-DELL Salient 8 Channel DVR, 8 - DM-1500-VFA3 Varifocal Mindome High Resolution Color Car, 16 - GE-3010 Crimp BNC Connector, 1 - UPS500 Uninteruptable Power Supply for DVR, 1 - 2000-002 Video Capture Card, 1 - 7700-200 RIO 2 Single Sided ID Card Printer, 1 - 7700-211 14ml Adhesive PVC Cards 100 Pack, 1 - 8120-060, Camera and Tripod Kit, 297 Hours LABOR - Estimate, Projected 346.5 Hours MISCELLANIOUS. The following supplemental items are also required for the security system: 1 – LOT Drawings for Submittals, 1 – LOT Permit and Inspection Fee, 1 – LOT Sound Test for Permit Approval, 1 – LOT Submittals for Plan Review, 1 - 4360PL Wire 18/2C STR OAS PLENUM, 1 - 4510PL Wire 22/4C STR OAS PLENUM, 1 - 4530PL Wire 22/6C STR OAS PLENUM, 2 - 7004-159 BLP 206 Processor Less Enclosure, 3 - 8300-184 iClass R10 Card Reader, 2 - AUR8791SLx626x24xLH Electrified Mortise Lockset Left Hand, 1 - AUR8791SLx626x24xRH Electrified Mortise Lockset Right Hand, 1 - AX-AL1012ULB Power Supply for RAMM and BLP Controllers, 1 - AX-AL600ULB Power Supply for Locks and Devices, 2 - AX-PD8 Fused Power Distribution Module, 3 - AX-RBST Interface Relay, 3 - DS-DS150i REX Motion Detector, 1 - N1C14TKL Key Lock for Enclosure, 1 - N1C364809 NEMA I Enclosure 36x48x09, 1 - NP4836 Enclosure Backplane, 2 PW-PS12550U 12V55AH Battery for 8 Hours Standby Minimum, 3 - TA2714 4.5x4.5x26Dx1104 Electrified 4 - Wire Door Hinge, 3 - SR-1078CBR Door Position Switch, 35 Hours LABOR - Estimate, Projected 44 Hours MISCELLANIOUS. The date and time for Quotes in response to this combination sysnopsis/solicitation is hereby extended to February 22, 2006, at 2:00 p.m., Local time. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (13-FEB-2006); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link to FedBizOpps document.
(http://www.fbo.gov/spg/DOJ/JMD/PSS/DOJAPG6G029/listing.html)
 
Place of Performance
Address: Dallas, Texas
Zip Code: 75201
Country: USA
 
Record
SN00987570-F 20060215/060213213529 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.