MODIFICATION
59 -- ONE THOUSAND WATTS HIGH POWER AMPLIFIER
- Notice Date
- 3/8/2006
- Notice Type
- Modification
- NAICS
- 334220
— Radio and Television Broadcasting and Wireless Communications Equipment Manufacturing
- Contracting Office
- Department of the Air Force, Air Force Materiel Command, AFFTC - AF Flight Test Center, 5 S WOLFE AVE, Edwards AFB, CA, 93524-1185
- ZIP Code
- 93524-1185
- Solicitation Number
- Reference-Number-F1S0AZ6011B002
- Response Due
- 3/9/2006
- Archive Date
- 3/24/2006
- Description
- Sources Sought Notice: The Air Force Flight Test Center (AFFTC), Edwards Air Force Base, CA is seeking potential sources capable of providing one-thousand watt high power amplifiers, in support of the 412th Test Wing range program upgrade for flight Termination Systems. Requirement is for; two (02) 1000 Watt High Power Amplifiers. Features: 1000-watts HPA Drawer w/Antenna, 3500-watts Power Supply Drawer. Local/Remote and Discrete Controller Drawer. These units will be integrated into the mobile ground flight termination system for the range safety group. The amplifiers will be utilized as part of the command and destruct system. In the event that an errant missile or unmanned vehicle is no longer controllable during a mission, the system will be used to terminate the vehicle to prevent catastrophe or mishaps to populated areas. "(Standard Specifications)" Equipment Consist List: (1) Microprocessor Controller Drawer 19?W x 21?D x 5.25?H Wt 20lbs (1) High Power Amplifier (HPA) Drawer 19?W x 27?D x 8.75?H Wt 120lbs (1) 3000 Watt DC Power Supply Drawer 19?W x 21?D x 5.25?H Wt 50lbs Frequency Range: 370-450MHz RF Output Power: 1000 Watts @ P1dB Minimum RF Gain: 60dB Minimum RF Input Power: -3dBm to +6dBm, +10dBm Maximum without damage RF Gain Flatness: +2db Maximum into 1.05:1 VSWR RF Output Power Selectivity: Continuously Variable with 20 dB Minimum range Harmonics and Spurious: -90 dBc min. @ 1,000 Watts RF Output Power up to 2750 MHz. RF Input & Output Impedance: 50 ohms Nominal RF Input & Output Connectors: Type ?N? Female RF Input & Output VSWR: 2.0:1 Maximum RF Input Protection: Integral Isolator protected up to 1250 watts with no damage Open or Short or any mismatch. RF Outputs: Two outputs from internal RF switch (Antenna and Dummy Load) RF Output Selection: Front panel with manual external control using TTL inputs control RF Switch External Control: TTL Low= RF to Antenna, TTL High=RF to Dummy Load RF Switching Time: <50 msec Noise Figure: 10dB Maximum Automatic Failure Capability: HPA?s will have this functionality built in for future upgrades. Control: Local Control via Color Touchscreen Display & Remote Control via Ethernet including Ground closure for transmitter On/Off via Ethernet. In addition, System Status/Faults include RF Levels both ALC and WA Modes, System Control & Status. Alarm Status, Over Temperature Shutdown and Forward and Reflected VSWR Monitoring. Cooling: Forced air via integral Front Panel Intake, and Rear Panel Exhaust Over Temperature Protection: Temperature Monitoring and Shutdown Environmental: Humidity, Salt Operating Temperature Range: -20 to 50 Degrees Celsius ambient Operating Altitude: 50,000 feet Maximum Operating Temperature: 0-95% non condensing Prime Input Power: 180 ? 264 VAC, Single (1) Phase Please note that this synopsis is for planning purposes only and does not constitute a solicitation for competitive bids/proposals and is not to be construed as a commitment by the Government. However, all interested parties who believe they can meet the requirements are invited to submit in writing complete information describing their ability to provide the capability and technology for the commercial software listed above. Firms responding to this synopsis must identify their company?s capabilities to perform the requirements described herein, reference the synopsis number and indicate whether or not that they are a small or small disadvantaged business concern as defined in FAR 52.219-1. The NAICS code is 334220. The information received as a result of this notice will be considered solely for the purpose of determining whether to conduct a competitive procurement. A determination by the Air Force not to open the requirement to open competition, based on response to this sources sought synopsis, is solely within the discretion of the Air Force. The Government does not intend to pay for any information provided under this sources sought synopsis. It is anticipated that a Firm Fixed Price contract will be awarded in April 2006. All responses may be sent via e-mail to willie.martin@edwards.af.mil or mailed to 412 Test Wing/PKDB, 5 South Wolfe Ave, Edwards AFB, CA 93524-1185, Attention: Willie Martin. Fax Number: 661-275-7855. Tel Number: 661-277-9659. Responses to this sources sought synopsis are due in the office by 1300 (1:00-pm), 09 March 2006.
- Place of Performance
- Address: Directorate of Contracting, Attn: Willie Martin (PKDB), 5 South Wolfe Avenue, Bldg#: 2800, Edwards Air Force Base, CA
- Zip Code: 93524-1185
- Country: USA
- Zip Code: 93524-1185
- Record
- SN01002196-W 20060310/060308212125 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |