SOLICITATION NOTICE
61 -- TRANSFORMER, PAD MOUNTED, DEAD FRONT, 150 KVA, 12KV DELTA - 480/277, 3 PHASE
- Notice Date
- 3/13/2006
- Notice Type
- Solicitation Notice
- Contracting Office
- N00604 1942 Gaffney Street, Ste 100 Bldg. 475-2, Code 200 Pearl Harbor, HI
- ZIP Code
- 96860-4549
- Solicitation Number
- N0060406T0338
- Response Due
- 3/22/2006
- Archive Date
- 4/21/2006
- Point of Contact
- Kristopher Tom 808-473-7514 ELIZA LEE, (808) 473-7546. ELIZA.LEE@NAVY.MIL
- Description
- This is a combined synopsis/solicitation for the acquisition of commercial supplies prepared in accordance with the format in FAR Subpart 12.6, Streamline Procedures for Evaluation and Solicitation for Commercial Items, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; a written solicitation will not be issued. PAPER COPIES OF THIS SOLICITATION WILL NOT BE AVAILABLE. All prospective offerors are responsible for monitoring this site for the release of amendments (if any) or other information pertaining to this solicitation. Solicitation No. N00604-06-T-0338 is issued as a Request for Quotation (RFQ) incorporating provisions and clauses in effect through Federal Acquisitions Circular 2005-07 and DFARS Change Notice 20060223. THIS PROCUREMENT IS RESTRICTED AND IS THEREFORE OPEN ONLY TO SMALL BUSINESS CONCERNS. The applicable NAICS Code is 335311 and 750 Employees respectively. Award will be conduct! ed under the provisions of FAR Part 12 Commercial Item and FAR Part 13 Simplified Acquisition Procedures. All qualified responsible business sources may submit a quotation, which shall be considered by the agency. FAR 52.212-2, Evaluation - Commercial Items is applicable to this procurement. A single Firm Fixed Priced contract will be awarded to the lowest priced, technically acceptable quote. The contractor must be registered in the Central Contractor Registration Database (CCR) to be eligible for Department of Defense contract awards. Lack of registration in the CCR database will make an offeror/quoter INELIGIBLE FOR AWARD. Please ensure compliance with this regulation when submitting your quote. Call 1-888-227-2423 or visit the Internet site http://www.ccr.gov/ for more information. THE REQUIREMENT IS TO PROVIDE THREE (3) TRANSFORMERS, PAD MOUNTED, DEAD FRONT, 150 KVA, 12KV DELTA 480/277, 3 PHASE. The Transformers shall conform to NEMA TR-1 and ANSI C57.12.26. The! y shall be self-cooled, mineral oil filled, 65 degrees centigrade temp erature rise, two copper winding type, and rated at 150 KVA, three phase, 60 hertz, 95KV BIL. The transformer shall be 12 KV Delta with (2) 2-1/2 percent taps above nominal rated voltage and (4) 2-1/2 percent below nominal rated voltage. Secondary shall be rated 480/277 volt. Impedance shall be a manufacturer’s standard. The transformer shall be fabricated with stainless steel tank, base, cabinet and painted with Pad mounted Green according to NEMA Standards. The unit shall consist of three integral compartments including transformer, primary and secondary compartments. The primary and secondary compartments shall be accessible only through lockable doors with the primary compartment being unlatched from inside the secondary compartment. The primary and secondary compartments shall be separated by an insulating barrier. The enclosure shall be provided with heavy gauge stainless steel channel lifting pad, lifting lugs and hinged doors capable of being padlocked. The ! finish shall be of the highest grade weather resistant, green paint applied over epoxy resin primary base coat. PRIMARY SECTION shall be Dead front, high voltage load break, bushing inserts, with three (3) radial feed, loadbreak oil switches and externally replaceable current limiting fuses. SECONDARY SECTION shall have the required low voltage bushing with NEMA spade type terminals with 6 holes. THE TRANSFORMERS SHALL BE FURNISHED WITH THE FOLLOWING ACCESSORIES AND OPTIONS: 1) Oil level gauge; 2) Pressure/vacuum gauge; 3) Drain/sample valve; 4) Dial thermometer; 5) Grounding Pad; 6) Externally operable no-load manual tap changer; 7) Upper filter press connection plug; 8) Pressure relief valve; 9) Lifting eye/lugs; 10) Three 200 amp bushing wells externally clamped & replaceable; 11) Diagrammatic nameplate; 12) Bolt on cabinet; 13) Provisions for balanced lifting; 14) Jacking provisions; 15) Four to five mils of undercoating on bottom & 2 inch – 4 inch up sides. 16) Fi! nish is standard padmount green; 17) Spare set of current limiting fus es. CLIN 0001 –TRANSFORMER, PAD MOUNTED, DEAD FRONT, 150 KVA, 12KV Delta 480/277, 3 PHASE. Quantity of 3 each. The required delivery date for the transformers is 60 days after delivery of contract (ADC) or state best delivery date. Pricing and shipping shall be FOB Destination to Pearl Harbor, HI 96860. Prospective quoters shall submit detailed specifications, along with pictures of the items, in sufficient detail to allow for a technical evaluation of the proposed transformers. The following FAR provisions and clauses are applicable to this procurement: 52.212-1, Instructions to Offerors - Commercial Items - Addendum to FAR 52.212-1, paragraph (b)(5): Offers shall provide an express warranty which at a minimum shall be the same warranty terms, including offers of extended warranties, offered to the general public; Express Warranties shall be included in the contract, delete paragraph h, multiple awards and insert single awards. FAR 52.212-4, Contract Terms and Condi! tions - Commercial Items; and FAR 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders - Commercial Items. THE FOLLOWING CLAUSES UNDER FAR 52.212-5 APPLY TO THIS REQUIREMENT AND SHALL BE INCORPORATED BY REFERENCE IN THE ORDER: FAR 52.219-6 ALTERNATE I, Notice of Total Small Business Set-Aside; FAR 52.222-3, Convict Labor; FAR 52.222-19, Child Labor – Cooperation with Authorities and Remedies; FAR 52.222-26, Equal Opportunity; FAR 52.222-35, Equal Opportunity for Special Disabled Veterans, Veterans of the Vietnam Era, and Other Eligible Veterans; FAR 52.222-36, Affirmative Action for Workers with Disabilities; FAR 52.222-37, Employment Reports on Special Disabled Veterans, Veterans of the Vietnam Era, and Other Eligible Veterans; FAR 52.232-36, Payment by Third Party. Additional contract terms and conditions applicable to this procurement are: DFARS 252.204-7004 ALTERNATE I, Required Central Contractor Registration; DFARS 252.212-70! 01, Contract Terms and Conditions Required to Implement Statutes or Ex ecutive Orders Applicable to Defense Acquisitions of Commercial Items. THE FOLLOWING CLAUSES UNDER FAR DFARS 252.212-7001 APPLY TO THIS REQUIREMENT AND SHALL BE INCORPORATED BY REFERENCE IN THE ORDER: DFARS 252.225-7001, Buy American Act and Balance of Payments Program. These clauses may be obtained via the Internet at FAR site: http://www.arnet.gov/far or DFARS site: http://www.acq.ods.mil/dp/dars/dfars.html or by request from this office. UNIT PRICES (SEPTEMBER 2005)(FISC Pearl Harbor); Contractor’s unit prices, when incorporated into a Government contract, will be released under the Freedom of Information Act (FOIA) without further notice to the Contractor that submitted the prices. If the Contractor does not want his unit prices released, then he shall submit his proposal with the appropriate legends regarding the data, and explain in detail why such data cannot be released as a public record under FOIA. REVIEW OF AGENCY PROTEST (FISCPH) (APR 2000) (a) The contracti! ng activity, Fleet and Industrial Supply Center, Pearl Harbor (FISCPH), will process agency protest in accordance with the requirements set forth in FAR 33.103 (d) (4), agency protests may be filed directly with the appropriate Reviewing Authority or a protester may appeal a decision rendered by a Contracting Officer to the Reviewing Authority. (c) The Reviewing Authority for FISCPH is the Director, Regional Contracting Department (Code 200), Fleet and Industrial Supply Center, Pearl Harbor, at 1942 Gaffney Street, Suite 100, Pearl Harbor, HI 96860-4549. Agency procurement protests should clearly identify the initial adjudicating official, i.e, the Contracting Officer or Reviewing Official. (d) The decision of the Contracting Officer will not extend the timeliness requirements of GAO. Therefore, any subsequent protest to GAO must be filed within 10 days of knowledge of initial adverse agency action. All prospective quoters interested in submitting a proposal for this s! olicitation shall include your name, address, telephone number, point of contact, fax number, e-mail address and commercial and Government Entity (CAGE) code. THE OFFEROR SHALL INCLUDE A COMPLETED COPY OF THE FOLLOWING PROVISIONS ALONG WITH THEIR OFFER: FAR 52.212-3 ALTERNATE I and Certifications Offeror Representations and Certifications – Commercial Items. Please complete your Representations and Certifications at the following website: http://orca.bpn.gov; DFARS 252.225-7000, Buy American Act--Balance of Payments Program Certificate. Any questions regarding this requirement must be in writing and submitted no later than 11:00 a.m. (Hawaii Standard Time) 20 MARCH 2006. Quotes must be received no later than 3:00 p.m (Hawaii Standard Time) 22 MARCH 2006. Quotes shall be faxed to (808) 473-0811. Quotes may be emailed to kristopher.tom@navy.mil. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (13-MAR-2006); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link to FedBizOpps document.
(http://www.fbo.gov/spg/DON/NAVSUP/N00604/N0060406T0338/listing.html)
- Record
- SN01005227-F 20060315/060313211915 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |