H -- Amendment 0001 to Scope of Work

Notice Date
3/14/2006
 
Notice Type
Modification
 
NAICS
238210 — Electrical Contractors
 
Contracting Office
USA Engineer District, Nashville, P.O. Box 1070, 801 Broad Street, Nashville, TN 37202-1070
 
ZIP Code
37202-1070
 
Solicitation Number
W912P5-06-T-0012
 
Response Due
3/21/2006
 
Archive Date
5/20/2006
 
Small Business Set-Aside
Total Small Business
 
Description
TENNESSEE RIVER LOCKS GROUNDING TESTS SPECIFICATION 1. Scope The contractor shall prepare a plan(s) and conduct lightning protection ground tests and inspections for Chickamauga (Single), Fort Loudon (Single), Guntersville (Double), Melton Hill(Single), Nickajack (Single), Pickwick (Double), Watts Bar (Single), Whee ler (Double), and Wilson Lock (Double) Projects. The contractor shall submit a test report within two weeks of completion of each Lock, including any comments and recommendations. The Government will evaluate all data and the contractor is not required t o perform any corrective actions/installations. The contractor shall provide their own sketch of the grounding test points with the final report and can assume that there will be approximately 80  100 points for a single lock and 160-190 points for a dou ble lock. Criteria for inspection points shall be as follows and will include all, but not be limited to the following listing: ***1. all exposed electrical and communications equipment visible on top of the lock wall and surrounding area; ***2. all electrical enclosures, raceways, j-boxes, conduit, etc., visible on top of the lock wall and surrounding area; ***3. all non-electrical equipment (handrails, flagpoles, light poles, camera towers, antennas, fences, etc.) visible on top of the lock wall and surrounding area; ***4. the electronic service entry to the lock. The locations of the locks on the Tennessee River can be founds at the following web site with the Points of Contact at each lock location. http://www.lrn.usace.army.mil/locks/ 2. Requirements - all tests must be conducted with a digital ground tester; - conduct an earth resistance test using the Four-Point method in accordance with IEEE standards; - perform soil resistance tests to establish grounding points; - perform current (ma) check on all ground conductors; - perform ground test on ground grid, gates, fences, handrails, light poles, floor mesh, transformers, haulage and other equipment with exposed metal on top of the lock wall and surrounding areas.
 
Place of Performance
Address: USA Engineer District, Nashville P.O. Box 1070, 801 Broad Street Nashville TN
Zip Code: 37202-1070
Country: US
 
Record
SN01005941-W 20060316/060314212308 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.