- TENNESSEE RIVER LOCKS GROUNDING TESTS SPECIFICATION 1. Scope The contractor shall prepare a plan(s) and conduct lightning protection ground tests and inspections for Chickamauga (Single), Fort Loudon (Single), Guntersville (Double), Melton Hill(Single), Nickajack (Single), Pickwick (Double), Watts Bar (Single), Whee ler (Double), and Wilson Lock (Double) Projects. The contractor shall submit a test report within two weeks of completion of each Lock, including any comments and recommendations. The Government will evaluate all data and the contractor is not required t o perform any corrective actions/installations. The contractor shall provide their own sketch of the grounding test points with the final report and can assume that there will be approximately 80 100 points for a single lock and 160-190 points for a dou ble lock. Criteria for inspection points shall be as follows and will include all, but not be limited to the following listing: ***1. all exposed electrical and communications equipment visible on top of the lock wall and surrounding area; ***2. all electrical enclosures, raceways, j-boxes, conduit, etc., visible on top of the lock wall and surrounding area; ***3. all non-electrical equipment (handrails, flagpoles, light poles, camera towers, antennas, fences, etc.) visible on top of the lock wall and surrounding area; ***4. the electronic service entry to the lock. The locations of the locks on the Tennessee River can be founds at the following web site with the Points of Contact at each lock location. http://www.lrn.usace.army.mil/locks/ 2. Requirements - all tests must be conducted with a digital ground tester; - conduct an earth resistance test using the Four-Point method in accordance with IEEE standards; - perform soil resistance tests to establish grounding points; - perform current (ma) check on all ground conductors; - perform ground test on ground grid, gates, fences, handrails, light poles, floor mesh, transformers, haulage and other equipment with exposed metal on top of the lock wall and surrounding areas. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (14-MAR-2006); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link to FedBizOpps document.
(http://www.fbo.gov/spg/USA/COE/DACA62/W912P5-06-T-0012/listing.html)
- Place of Performance
- Address: USA Engineer District, Nashville P.O. Box 1070, 801 Broad Street Nashville TN
- Zip Code: 37202-1070
- Country: US
- Zip Code: 37202-1070
- Record
- SN01006618-F 20060316/060314214154 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |