Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF APRIL 09, 2006 FBO #1595
MODIFICATION

66 -- Spectral and Radiometric Calibration Facility for MidWave and LongWave Infrared Sensors

Notice Date
4/7/2006
 
Notice Type
Modification
 
NAICS
541710 — Research and Development in the Physical, Engineering, and Life Sciences
 
Contracting Office
Department of the Navy, Office of Naval Research, Naval Research Laboratory, 4555 Overlook Ave. S.W., Washington, DC, 20375
 
ZIP Code
20375
 
Solicitation Number
N00173-06-R-LS02
 
Response Due
4/11/2006
 
Archive Date
4/11/2007
 
Point of Contact
Lisa Fleming, Contract Specialist, Phone 202-767-3739, Fax 202-767-6197,
 
E-Mail Address
lisa.fleming@nrl.navy.mil
 
Small Business Set-Aside
Total Small Business
 
Description
The purpose of this amendment is to answer questions and to extend the response date of this solicitation. 1. The solicitation is hereby extended by one day. Quotes must be received no later than 4pm, 11 April 2006. Please be reminded that we will be accepting e-mailed and faxed quotes. 2. Questions and Answers: Question 1: Does the government have a preference between the following two approaches? A system that includes a blackbody source that either meets stipulated accuracy criteria (0.1 degrees C), but only over the central 10 inches, or alternatively meets somewhat looser specifications (0.2 degrees C) over the full 12 inch area. Answer: The government would prefer the stipulated accuracy over the central 10 inches of the source. Question 2: Can the government provide clarification of the use of a "spectral radiance" specification on the collimated source? This is a non-standard use of a unit customarily applied to diffuse sources in a context where the source is distinctly not diffuse. Answer: The Collimated Infrared Radiation Source can be thought of as being the equivalent of a diffuse source within the steradiency of the (almost) collimated beam, and having zero spectral radiance outside the steradiency of the beam. Perhaps a familiar optical example will help explain the intent of the specification. If a small, diffuse radiating source is placed at the focus of an off-axis parabolic mirror with 100 percent reflectivity, then the beam reflected off the mirror will be approximately collimated. In this case, the Watts per meter squared per steradien per micron in the beam will be equal to the Watts per meter squared per steradien per micron emanating from the small diffuse radiating source. 3. All other terms and conditions remain unchanged. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (07-APR-2006); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link to FedBizOpps document.
(http://www.fbo.gov/spg/DON/ONR/N00173/N00173-06-R-LS02/listing.html)
 
Place of Performance
Address: Contractor's Facility
 
Record
SN01023960-F 20060409/060407223531 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.