Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF APRIL 21, 2006 FBO #1607
SOLICITATION NOTICE

40 -- HOIST

Notice Date
4/19/2006
 
Notice Type
Solicitation Notice
 
NAICS
333923 — Overhead Traveling Crane, Hoist, and Monorail System Manufacturing
 
Contracting Office
Department of the Navy, Naval Supply Systems Command, FISC PUGET SOUND, 467 W STREET, BREMERTON, WA, 98314-5000
 
ZIP Code
98314-5000
 
Solicitation Number
N00406-06-T-0702
 
Response Due
5/1/2006
 
Archive Date
5/16/2006
 
Small Business Set-Aside
Total Small Business
 
Description
DESCRIPTION: 1 TON JDN PROFI TI AIR HOIST WITH 60' LIFT OR EQUAL. P/N 1-TON TI OR EQUAL PER ATTACHED 0001. CERTIFICATE OF COMPLIANCE OF STATIC AND DYNAMIC LOAD TEST REQUIRED PER ATTACHMENT ITEM 1. HOIST SHALL HAVE INTERNAL PERMANANT MOTOR LUBRICATION (AIR HOIST REQUIRING EXTERNAL LUBRICATION SYSTEM WILL NOT BE ACCEPTED). INTEGRATED MAIN AIR EMERGANCY-STOP VALVE WITH OVERLOAD PROTECTION CAPABILITY. MAX WEIGHT OF AIR HOIST (WITH 10' OF LOAD CHAIN) SHALL NOT EXCEED 62 LBS. MIN HEADROOM NOT TO EXCEED 17-3/4", BODY WIDTH NOT TO EXCEED 12", HOIST MUST BE SUITABLE FOR USE IN HAZARDOUS ENVIRONMENTS SUCH AS PAINT SHOP, CHEMICAL SHOP EXPOSURE (BRIGHT AND ACID DIP TANKS), REFINIERES AND BE ACCEPTABLE FOR USE IN FOOD INDUSTRY. (FME ARE AS REQUIRED FOR SPS). HOIST MUST BE CAPABLE OF OPERATING TEMPATURES -20 C(-4 DEG F) TO +70C (158 DEG F). HOIST SHALL HAVE NO LIMITS TO OPERATION DURATION AND NO LIMITS IN STARTS/STOPS PER HOUR (100% DUTY RATING). NOISE RATING HOIST SHALL NOT EXCEED 80 DB(A). THE SAFETY FACTOR SHALL BE NO LESS THAN 5 OF THE RATED LOAD. HOIST SHALL BE PNEUMATIC WITH OPERATING AIR PRESSURE OF 85 PSI (6 BAR). HOIST SHALL BE CAPABLE OF WITHSTANDING SHORT TERM PRESSURE INCREASE (UP TO 130 PSI) WITHOUT DAMAGE. HOIST SHALL BE SUITABLE FOR HORIZONTAL PULLING. 5 REQUIRED. 2 TON JDN PROFI TI AIR HOIST WITH 60' LIFT OR EQUAL. P/N 2-TON TI OR EQUAL PER ATTACHED 0001. CERTIFICATE OF COMPLIANCE OF STATIC AND DYNAMIC LOAD TEST REQUIRED PER ATTACHMENT ITEM 1. HOIST SHALL HAVE INTERNAL PERMANANT MOTOR LUBRICATION (AIR HOIST REQUIRING EXTERNAL LUBRICATION SYSTEM WILL NOT BE ACCEPTED). INTEGRATED MAIN AIR EMERGANCY-STOP VALVE WITH OVERLOAD PROTECTION CAPABILITY. MAX WEIGHT OF AIR HOIST (WITH 10' OF LOAD CHAIN) SHALL NOT EXCEED 76 LBS. MIN HEADROOM NOT TO EXCEED 20", BODY WIDTH NOT TO EXCEED 12", HOIST MUST BE SUITABLE FOR USE IN HAZARDOUS ENVIRONMENTS SUCH AS PAINT SHOP, CHEMICAL SHOP EXPOSURE (BRIGHT AND ACID DIP TANKS), REFINIERES AND BE ACCEPTABLE FOR USE IN FOOD INDUSTRY. (FME ARE AS REQUIRED FOR SPS). HOIST MUST BE CAPABLE OF OPERATING TEMPATURES -20 C(-4 DEG F) TO +70C (158 DEG F). HOIST SHALL HAVE NO LIMITS TO OPERATION DURATION AND NO LIMITS IN STARTS/STOPS PER HOUR (100% DUTY RATING). NOISE RATING HOIST SHALL NOT EXCEED 80 DB(A). THE SAFETY FACTOR SHALL BE NO LESS THAN 5 OF THE RATED LOAD. HOIST SHALL BE PNEUMATIC WITH OPERATING AIR PRESSURE OF 85 PSI (6 BAR). HOIST SHALL BE CAPABLE OF WITHSTANDING SHORT TERM PRESSURE INCREASE (UP TO 130 PSI) WITHOUT DAMAGE. HOIST SHALL BE SUITABLE FOR HORIZONTAL PULLING. 5 REQUIRED. 3.2 TON JDN PROFI TI AIR HOIST WITH 60' LIFT OR EQUAL. P/N 3.2-TON TI OR EQUAL PER ATTACHED 0001. CERTIFICATE OF COMPLIANCE OF STATIC AND DYNAMIC LOAD TEST REQUIRED PER ATTACHMENT ITEM 1. HOIST SHALL HAVE INTERNAL PERMANANT MOTOR LUBRICATION (AIR HOIST REQUIRING EXTERNAL LUBRICATION SYSTEM WILL NOT BE ACCEPTED). INTEGRATED MAIN AIR EMERGANCY-STOP VALVE WITH OVERLOAD PROTECTION CAPABILITY. MAX WEIGHT OF AIR HOIST (WITH 10' OF LOAD CHAIN) SHALL NOT EXCEED190 LBS. MIN HEADROOM NOT TO EXCEED 23.5", BODY WIDTH NOT TO EXCEED 12", HOIST MUST BE SUITABLE FOR USE IN HAZARDOUS ENVIRONMENTS SUCH AS PAINT SHOP, CHEMICAL SHOP EXPOSURE (BRIGHT AND ACID DIP TANKS), REFINIERES AND BE ACCEPTABLE FOR USE IN FOOD INDUSTRY. (FME ARE AS REQUIRED FOR SPS). HOIST MUST BE CAPABLE OF OPERATING TEMPATURES -20 C(-4 DEG F) TO +70C (158 DEG F). HOIST SHALL HAVE NO LIMITS TO OPERATION DURATION AND NO LIMITS IN STARTS/STOPS PER HOUR (100% DUTY RATING). NOISE RATING HOIST SHALL NOT EXCEED 80 DB(A). THE SAFETY FACTOR SHALL BE NO LESS THAN 5 OF THE RATED LOAD. HOIST SHALL BE PNEUMATIC WITH OPERATING AIR PRESSURE OF 85 PSI (6 BAR). HOIST SHALL BE CAPABLE OF WITHSTANDING SHORT TERM PRESSURE INCREASE (UP TO 130 PSI) WITHOUT DAMAGE. HOIST SHALL BE SUITABLE FOR HORIZONTAL PULLING. 5 REQUIRED. FOB DESTINATION. SOLICITATION AVAILABLE 4/19/06. ALL RESPONSIBLE SOURCES MAY SUBMIT/BID WHICH SHALL BE CONSIDERED BY FISC PUGET SOUND. TELEPHONE REQUEST WILL NOT BE HONORED. E-MAIL OR FAX REQUESTS FOR SOLICITATION TO 360-476-4656.
 
Place of Performance
Address: 467 W STREET, BREMERTON WA
Zip Code: 98314
Country: US
 
Record
SN01031302-W 20060421/060419221251 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.