MODIFICATION
Y -- 4 BCT (HEAVY) BRIGADE DINING FACILITY
- Notice Date
- 5/5/2006
- Notice Type
- Modification
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- US Army Corps of Engineer - Omaha District, 106 S. 15th Street, Omaha, NE 68102-1618
- ZIP Code
- 68102-1618
- Solicitation Number
- W9128F-06-R-0022
- Response Due
- 6/30/2006
- Archive Date
- 8/29/2006
- Small Business Set-Aside
- Service-Disabled Veteran-Owned
- Description
- Brigade Dining Facility Service-Disabled, Veteran-Owned Small Business Best-Value, Two-Phase Design-Build (D/B) Request for Proposal (RFP) NAICS Code is 236220******* On or about 12 May 2006, this office will issue a Request for Proposal for a Service Disabled Veteran-Owned Small Business Two Phase Design/Build contract. This solicitation is restricted 100% to Service Disabled Veterans-Owned Small Business participation . A pre-proposal conference and site visit is scheduled for 17 May 2006 at the Special Events Center, BLDG 1829, Ft. Carson, CO (10:00 AM). Contractors should allow 15 minutes to process through the entrance gates (Gates 1, 4, & 20) please do not use GATE 2. To down load a copy of a map of the installation please click on the following link https://www.nwo.usace.army.mil/html/ct-m/webpage.htm then click on Northwestern Regional Army Transformation Program and finally click on Pre-Proposal Site Map 17 MA Y 2006. Point of contact (POC) is Major Hudson or Annette Smith 719-526-5448. Contractors interested in attending the Pre-proposal conference and site visit will have their vehicle searched. Please have your drivers license, registration, and proof of i nsurances available. You may register with the POC listed above. You do not have to call the POC to give your gate information. Foreign National contractors must have a current passport and will be escorted by Department of Defense personnel. The work will include the following: (Any quantities are approximations) This contract will require design and construction of one Dining Facility (~27,000 SF) within a clearly defined area of land (or footprint). Disciplines such as Architectural, Structural, Civil, Environmental, Electrical and Mechanical will be required fo r design. Innovative construction techniques and facilities that allow fast track execution of the project will be necessary to meet Department of Army requirements for facility completion. Supporting facilities include sitework and all required support utilities, security and area lighting, information systems, fire protection and alarm systems, storm drainage, landscaping, site improvements, paving, walks, curbs, gutters, exterior signage, and parking. Design and construction to LEED Silver standards and to meet Anti-Terrorism and Force Protection (AT/FP) requirements is included for all facilities per Department of Army (DA) guidance. Special requirements may include special foundations due to expansive soils prevalent at Fort Carson; Energy Monitoring Control Systems (EMCS); and Intrusion Detection Systems (IDS). Kitchen equipment will be required as part of the facility design and construction. Comprehensive building and furnishings related interior design services are also required but will be a deliverable to the Government that will allow separate procurement of furnishings. Installation of furnishings is required after receipt of Government procured property. Proposal Evaluation: Award of this project will be based on the two phase design/build procedures in accordance with FAR 36.3. Firms will be given at least 30 days to submit a proposal for Phase 1(technical approach, technical qualification, past performance and bonding). Pre proposal meetings will be conducted after issuance of the Request for Proposal (RFP). For Tier 1 or Industrial facilities in particular, firms will be evaluated for their experience in completing similar projects in the commercial sector using modular, pre -fabricated or pre-engineered, panelized or tilt-up building solutions, and their demonstrated ability to deliver similar projects at reduced time and cost. Approximately up to five firms will be consider to proposed on Phase 2 depending upon the interest that was received in Phase 1. In accordance with FAR 36.303-1, only those firms that are pre-qualified in phase 1 will be encouraged to submit technical and price during phase 2. Oral presentations will be schedule during Phase 2.***** The estimated construction cost of this project is $12.6 Million. ***** Contractor's Quality Control will be a requirement in this contract. The Contractor will be required to commence work within 10 days after notice to proceed and complete the work within the time period stipulated in the contract. The contract will include provisions for liquidated damages in case of failure to complete the work in the time allowed. The proposer will be required to provide evidence they are bondable in the amount of $15,000,000.***** The Request for Proposal (RFP) will no longer be available on Compact Disk (CD-ROM). The RFP will not be provided in a printed hard copy format. A plan holders list is not available. Solicitation documents will post on FedTeDS.****** FedTeDS is a web-based dissemination tool designed to safeguard acquisition-rela ted information. When solicitation documents have been issued and posted to FedTeds, synopsis or pre-solicitation notice will be amended and a link provided to access FedTeds. The process to download from FedTeds is: 1. Find the solicitation announcement in Fed Biz Opps (www.fbo.gov). 2. Once you open the bid announcement on FED BIZ OPPS, there will be a link to the solicitation on FedTeds in the remarks section. 3. Click on the link. If you are a first time user, you will have to register. Registration i nstructions can be found on the FedTeds website (https://www.fedteds.gov) by clicking on the Register Process option. The following information is required: 1.Central Contractor Registration (CCR) Marketing Partner Identification Number (MPIN) 2. DUNS Numb er or CAGE code. 3. Telephone Number, 4.E-Mail address. **** Bidders (Offerors): Please be advised of on-line registration requirement in Central Contractor Registration (CCR) database http://www.ccr.gov/ and directed solicitation provisions concerning electronic annual On-line Representations and Certifications (OR CA) at https://orca.bpn.gov. Representations and certifications are required to be updated annually as a minimum to keep information current, accurate and complete. The electronic annual representations and certifications are effective until one year from date of submission or update to ORCA. Questions regarding Contracting should be made to Ms. Famane Brown: 402-221-3116. Telephone calls regarding Small Business matters should be made to Mr. Hubert Carter: 402-221-4110. Telephone calls on contents of drawings and specifications should be made to the Project Manager, Mr. Bert Matya at: (402) 221-3828 or Specification Section, Mr. Doug Larsen at: (402) 221-4547.
- Place of Performance
- Address: US Army Corps of Engineer - Omaha District 106 S. 15th Street, Omaha NE
- Zip Code: 68102-1618
- Country: US
- Zip Code: 68102-1618
- Record
- SN01042977-W 20060507/060505222141 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |