Z--Z -- Replacement of Steam Piping

Notice Date
5/10/2006
 
Notice Type
Solicitation Notice
 
Contracting Office
Attn: Department of Veterans Affairs Boston Healthcare System, Contracting Officer, (90C), 150 So. Huntington Avenue, 10th Floor, Boston, Massachusetts 02130
 
ZIP Code
02130
 
Solicitation Number
VA-523-06-IB-0004
 
Response Due
6/22/2006
 
Archive Date
7/22/2006
 
Small Business Set-Aside
Service-Disabled Veteran-Owned
 
Description
Contractor shall completely prepare the site as necessary for operation, including demolition, removal of existing items, and renovations in phases as required by the contract drawings and specifications for the VA Boston Healthcare System, Boston, MA. Provide all necessary labor, material and coordination to complete the work described or implied by the construction documents. All equipment, components and articles installed shall be complete for operation, service and maintenance for the purpose intended not limited to the details and information provided in accordance with the manufacturers procedures and recommendations. All equipment, materials and articles shall be of the most suitable grade, size and capacity for the purpose intended. This procurement is 100% set-aside for SDVOSB(Small Disadvantaged Veteran Owned Small Business). The NAIC code is 238220 with a small business size standard of $13 million applies to this procurement. Bidders are requested to submit evidence of their SDVOSB certification with their bid. Cost range is between $1,000,000 and $2,000,000. Only one pre-site visit will be scheduled and announced in the solicitation. The solicitation will be available on or about 5/22/06. The bids will be due on or about 6/22/06. Requests for the solicitation must be in writing. Fax your request to 857-364-6521 to Carol AhNee. No telephone requests will be accepted. Bid Item 1: Base Bid with 450 calendar days contract duration performed in phases as indicated or required. For all finned tube radiation steam terminal units and unit ventilators shown on the drawings, work shall include replacement or retrofit of steam traps for same, provision of new isolation valves for same, and provision of new non-electric control valves for same. In addition, work shall include steam trap testing and adjusting services for all existing finned tube radiation steam terminal units and unit ventilator steam coils shown on the drawings. Bid Item 2: Base Bid minus all work associated with Heating Zone No. 1 as shown on the drawings with 425 calendar days contract duration performed in phases as indicated or required. Bid Item 3: Base Bid minus all work associated with Heating Zones No. 1 + 2 as shown on the drawings with 400 calendar days contract duration performed in phases as indicated or required. Bid Item 4: Base Bid minus all work associated with Heating Zones No. 1 + 2 + 3 as shown on the drawings with 375 calendar days contract duration performed in phases as indicated or required. Bid Item 5: Unit Prices. Refer to Section 01200. LIST OF UNIT PRICES A. Unit Price No. 1: Modifications to Type 1 (Small) Radiators: 1. Description: Modifications shall include new 1/2" control valve body, new self-contained unit-mounted thermostat, 2 isolation ball valves, new trap insert kit, and all work as shown on drawings and in accordance with the specifications. 2. Unit of Measurement: Each. B. Unit Price No. 2: Modifications to Type 2 (Medium) Radiators: 1. Description: Modifications shall include new 1/2" control valve body, new self-contained unit-mounted thermostat, 2 isolation ball valves, new trap insert kit, and all work as shown on drawings and in accordance with the specifications. 2. Unit of Measurement: Each. C. Unit Price No. 3: Modifications to Type 3 (Large) Radiators: 1. Description: Modifications shall include new 3/4" control valve body, new self-contained unit-mounted thermostat, 2 isolation ball valves, new trap insert kit, and all work as shown on drawings and in accordance with the specifications. 2. Unit of Measurement: Each. D. Unit Price No. 4: Remote Thermostat: 1. Description: Provision of new remote thermostat, 6' capillary tubing, and molding kit to be applied to any radiator or unit ventilator location as shown on drawings and in accordance with the specifications. Unit of Measurement: Each.
 
Place of Performance
Address: 150 South Huntington Ave., Boston, MA
Zip Code: 02130
Country: United States
 
Record
SN01045354-W 20060512/060510220549 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.