SOLICITATION NOTICE
Y -- REPLACE FAMILY HOUSING, PHASE 4 (FY 05) & PHASE 5 (FY 06), ELLSWORTH AFB, SOUTH DAKOTA.
- Notice Date
- 5/31/2006
- Notice Type
- Solicitation Notice
- NAICS
- 236115
— New Single-Family Housing Construction (except Operative Builders)
- Contracting Office
- US Army Corps of Engineer - Omaha District, 106 S. 15th Street, Omaha, NE 68102-1618
- ZIP Code
- 68102-1618
- Solicitation Number
- W9128F-06-R-0007
- Response Due
- 7/20/2006
- Archive Date
- 9/18/2006
- Small Business Set-Aside
- N/A
- Description
- 31 May 2006 SOLICITATION NO. W9128F-06-R-0007 On or about 15 June 2006, this office intends to issue Request for Proposal (RFP) for the Design/Build of REPLACE FAMILY HOUSING, PHASE 4 & 5, ELLSWORTH AFB, SOUTH DAKOTA. Proposals will be received on or about 20 July 2006 at 1400 (2:00 PM CST) hours. This solicitation is UNRESTRICTED and open to both large and small business participation. Site Visit/Pre-Proposal Conference A formal Site Visit and Pre-Proposal conference will not be scheduled since an Industry Forum was recently held on 9 May 2006. If a site visit is requested, please contact the following: Ellsworth AFB Resident Engineer, U.S. Army Corps of Engineers, 2149 S cott Drive, Ellsworth AFB, SD 57706, Telephone: (605)923 2983. FAX (605)923 2558 Project Description: This is a Design-Build Project. The work consists of design and construction of the Replace Family Housing, Phase 4 and 5 project at Ellsworth AFB, South Dakota. The work consists of demolition of 328 existing housing units (212 on Phase 4 & 116 on Phase 5 ) and replacing \ construction of 135 new units (75 on Phase 4 and 60 on Phase 5). New units will be a combination of duplex configuration and detached single family dwellings with the potential use of 4-plex townhouses on some JNCO units as necessary to p rovide the minimum scope within the construction cost limitation. Infrastructure work includes utility upgrades, street work, etc. All units will require double-car garages, central air conditioning, refrigerators, garbage disposals, dishwashers, water he aters, range-ovens, automatic garage door openers, carbon monoxide detectors and smoke detectors, as a minimum. RFP Evaluation - Firms desiring to participating in the RFP process will submit technical requirements as required by the solicitation and will be evaluated based on the best value approach considering technical elements for evaluation - e.g., Experience, Past Performance, Project Management, Utilization of Small Business, Design Factors, and Price. An adjectival method of evaluation ratings will be used to evaluate the technical factors. Price will be reviewed for realism and reasonableness. The estimated design and construction cost of this project is between $30,000,000 and $40,000,000. The Construction Cost Limitation for Phase 4 and 5 will be specified in the advertised Solicitation. Large business concerns submitting bids for services exceeding $500,000 or for construction exceeding $1,000,000, shall comply with Federal Acquisition Regulation 52.219-9 regarding the requirement for a subcontracting plan. The U.S. Army Corps of Engineer s considers the following goals reasonable and achievable for this contract: (a) Small Business: 51.2% of planned subcontracting dollars. (b) Small Disadvantaged Business: 8.8% of planned subcontracting dollars*. (c) Women Owned Small Business: 7.3% of pla nned subcontracting dollars*. (d) Service-Disabled Veterans: 1.5% of planned subcontracting dollars*. (e) Hubzones: 3.1% of planned subcontracting dollars*. *- Small business concerns owned and controlled by. The Contractor will be required to commence work within 10 days after notice to proceed. Provisions will be included for liquidated damages in case of failure to complete the work in the time required. Performance and payment bonds will be required. Bondin g documents including the power of attorney shall bear an original signature by an officer of the surety. Bidders (Offerors): Please be advised of on-line registration requirement in Central Contractor Registration (CCR) database http://www.ccr.gov/ and directed solicitation provisions concerning electronic annual On-line Representations and Certifications (OR CA) at http://orca.bpn.gov. Representations and certifications are required to updated annually as a minimum to keep information current, accurate and complete. The electronic annual representations and certifications are effective until one year f rom date of submission or update to ORCA. Obtaining Draft RFP Documents: This office will no longer send copies (paper or CDS) of amendments and solicitations to interested parties. Solicitation documents will be posted on Federal Technical Data Solutions (FedTeDS). FedTeDS is a web-based dissemin ation tool designed to safeguard acquisition-related information. When solicitation documents have been issued and posted to FedTeDs, synopsis or pre-solicitation notice will be amended and a link provided to access FedTeDS*. The process to download from FedTeDS is: 1. Find solicitation announcement in Fed Biz Opps (www.fbo.gov) 2. *Once you open the bid announcement on Fed Biz Opps, there will be a link to the solicitation on FedTeDS in the remarks section. Click on the link. 3. If you are a first time us er, you will have to register** (see info included below); if not log in and open the solicitation. 4. Once you have the solicitation open, you can begin downloading the various files to your location. **Registration instructions can be found on the FedTeDS website https://www.fedteds.gov) by clicking on the Register with FedTeDS hyperlink. Interested bidders should select the Begin Vendor/Contractor Registration Process option. The information listed be low is required to register. 1. Central Contractor Registration (CCR) Marketing Partner Identification Number (MPIN) 2. DUNS Number or CAGE code 3. Telephone NumbeR 4. E-Mail address Questions regarding contractual issues should be made to: 402 221 4298 or Mel.E.Vogt@usace.army.mil. Telephone calls regarding Small Business matters should be made to: 402 221 4110. Telephone calls on contents of drawings and specifications should be made to the Project Manager at: (402)221 3985 or Specification Section at: (402)221 4411. Commander U.S. Army Engineer District, Omaha ATTENTION: CENWO-CT-M 106 South 15th Street Omaha, NE 68102 1618
- Place of Performance
- Address: US Army Corps of Engineer - Omaha District 106 S. 15th Street, Omaha NE
- Zip Code: 68102-1618
- Country: US
- Zip Code: 68102-1618
- Record
- SN01059886-W 20060602/060531221035 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |