SOLICITATION NOTICE
M -- Specialized HEPA Filer Installation, Maintenance, Repair, Testing Inspection & Certification
- Notice Date
- 7/6/2006
- Notice Type
- Solicitation Notice
- NAICS
- 333411
— Air Purification Equipment Manufacturing
- Contracting Office
- Department of Energy, Sandia Corp. (DOE Contractor), Sandia National Laboratories, PO Box 5800 MS: 0115, Albuquerque, NM, 87185
- ZIP Code
- 87185
- Solicitation Number
- Reference-Number-SNL13250
- Response Due
- 7/24/2006
- Archive Date
- 8/30/2006
- Description
- TITLE: HEPA Filer Installation, Maintenance, Repair, Testing Inspection & Certification for Clean Room Applications Contractor shall furnish labor and materials, as required herein, to inspect, maintain, repair, disassemble, reassemble, relocate, modify, test, and balance contamination control facilities. They will also certify air flow unidirectional and non-unidirectional airflow for approximately three-hundred (300) clean benches, clean rooms, and other units, such as vacuum cleaners, exhaust systems and Heating Ventilation and Air Conditioning (HVAC) units. Of the three-hundred (300) units, historical data shows that about eighty percent (80%) are tested annually and the remaining twenty percent (20%) are tested twice every year. A small percentage of HEPA filters will require testing at other intervals based upon the frequency and type of customer operations, corrective maintenance, and acceptance testing following major modifications or relocation of operations. Contractor shall fill and deliver orders for High Efficiency Particulate Air (HEPA) filters maintenance parts included in that will be included in Attachment A at RFQ issuance. Sandia reserves the right to procure by other means any item provided under this agreement. In performing work under this agreement, Contractor must adhere to prudent business practices, sand the following standards: - ASME N510-1995, Testing of Nuclear Air Treatment Systems - ASME N509 1989, Nuclear Power Plant Air-Cleaning Units and Components - ASME NQA-1 2000, Quality Assurance Requirements for Nuclear - Facility Applications - ASME AG-1-2003, Code on Nuclear Air and Gas Treatment - DOE-STD-3020-05, Specification for HEPA Filters used by DOE Contractors - 40 CFR Part 61, Subpart H-National Emission Standards for Emissions of Radionuclides other than Radon from Department of Energy Facilities - ISO 14644-1 1999, Cleanrooms and Associated Controlled Environments Part 1: Classification of Air Cleanliness First Edition - ISO 14644-2 2000 Cleanrooms and Associated Controlled Environments Part 2: Specifications for Testing and Monitoring to Prove Continued Compliance with ISO 14644-1 First Edition - DOE-HDBK-1169-2003, Nuclear Air Cleaning Handbook Contractor shall have at a minimum one (1) person or technician who has completed formal training with NUCON International, Inc. Training must be completed every three years to meet the NUCON training requirement. Contractor shall pay for all expenses incurred to meet the mandatory NUCON training requirement. DNFSB Recommendation 2000-02, Configuration Management of Vital Safety Systems. For more information on NUCON International, Inc, Contractor can access their website at http://www.NUCON-INT.com/company/training . In addition, Contractor must have a National Environment Balancing Bureau (NEBB) certification or equivalent and shall be designated as a Clean Room Performance Testing Firm; Contractor shall pay for all expenses incurred to meet the mandatory NEBB training requirement. For more information on NEBB, Contractor can access their website at http://www.NEBB.org NOTE: ALL INQUIRIES AND RESPONSES MUST BE SENT ELECTRONICALLY TO JEANE P. Wallace at eamil: JPWALLA@SANDIA.GOV
- Place of Performance
- Address: Sandia National Laboratories, PO Box 5800, Albuquerque, NM
- Zip Code: 87185
- Country: USA
- Zip Code: 87185
- Record
- SN01083402-W 20060708/060706220317 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |