Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JULY 30, 2006 FBO #1707
MODIFICATION

Y -- MUNITIONS FACILITIES, SHAW AIR FORCE BASE, SUMTER, SOUTH CAROLINA

Notice Date
7/28/2006
 
Notice Type
Modification
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
Department of the Navy, Naval Facilities Engineering Command, NAVFAC Southeast, South, 2155 Eagle Drive, North Charleston, SC, 29406, UNITED STATES
 
ZIP Code
00000
 
Solicitation Number
N62467-06-R-0104
 
Response Due
9/6/2006
 
Archive Date
9/21/2006
 
Point of Contact
Kevin Logan, Contract Specialist, Phone 843-820-5775, Fax null, - Shirley Berry, Contract Specialist, Phone 843-820-5938, Fax 843-818-6854,
 
E-Mail Address
kevin.logan@navy.mil, berrysa@efdsouth.navfac.navy.mil
 
Small Business Set-Aside
Total HUB-Zone
 
Description
THIS IS A SOLICATATIONON/REQUEST FOR PROPOSALS. THIS IS 100% HUBZONE SET-ASIDE. The Solicitation Number for this announcement is N62467-06-R-0104. THIS IS A 100% PLANS AND SPECIFICATIONS CONSTRUCTION of Munitions Facilities at Shaw Air Force Base in Sumter, South Carolina. The 2002 NAICS Code for the proposed acquisition is 236220, Commercial and Institutional Building Construction, and the small business size standard is $31 Million. The Federal Supply Code is Y171, Construction of Facilities/Office Buildings. Under FAR guidelines, the prime contractor must have the capability to perform at least 20 percent of the contract work with its own employees. The proposed solicitation will be formatted as a Request for Proposal (RFP) in accordance with requirements designated by sections of the FAR 15.203 and NFAS for a negotiated procurement utilizing the construction selection procedures of FAR 36. This method permits evaluation of proposals based on price competition, technical merits and other factors; permits impartial and comprehensive evaluation of offerors' proposals; permits discussions if necessary; and ensures selection of the source whose performance provides the best value to the Government. The Munitions Facilities construction project consists of four separate buildings. The proposed sites for the new buildings are located in the existing Munitions Facilities Compound on the northeastern portion of the base. The site area is defined by an existing secured perimeter chain-link fence and includes munitions and equipment storage areas. The Munitions Administration/Mobility Storage Building combines administrative and storage functions. The Munitions Administration/Mobility Storage Building consists of approximately 6960 SF of administrative space and 8042 SF of high bay storage for a total of 15,002 SF gross building area. The new facility will be constructed utilizing a pre-engineered building structure with a 3:12 pitch metal roof and metal siding. A 4 ft height, split-face CMU wainscot will be provided around the administration portion of the new facility. The remainder of the exterior wall will consist of pre-engineered metal panels. Interior partitions in the administration area will be metal studs with gypsum board. Floors will be carpet in the offices and VCT in the corridors and break rooms. Restrooms and locker rooms will have ceramic tile floors. The storage bays consist of twelve bays (55 ft x 12 ft) for trailer storage and space for training functions. Demolition of Buildings 1800, 1801, and 1803 will be required before construction is started on the new building. Demolition of Buildings 1805 and 1807 will be deferred until construction is complete on the new building in order to phase the occupancy of the administration areas. The total demolition area is 5000 SF The Four-Bay Maintenance Facility contains approximately 3784 SF of administrative space and 5166 SF of munitions maintenance area consisting of four drive-through bays for a total of approximately 8950 SF. Three of the walls separating the bays will be Substantial Dividing Walls or ?Blast Walls?, which are required for prevention of propagation of burning reactions. The new facility will be constructed utilizing a pre-engineered building structure with a 3:12 pitch metal roof and metal siding. Interior partitions in the administration area will be metal studs with gypsum board. Floors will be carpet in the offices and VCT in the corridors and break rooms. Restrooms and locker rooms will have ceramic tile floors. Specialized equipment in the maintenance bays includes low and high-pressure air and 400hz power for support of portable air ground equipment. A catenary lightning protection will be provided for the Four-Bay Maintenance Facility. The third and fourth buildings are each 2080 square foot munitions storage igloos. The storage igloos will have reinforced concrete bearing walls with reinforced concrete roof, floor and foundation systems. The structures will be earth covered and will feature blast-resistant steel doors, explosion-proof lighting, exterior security lighting, an intrusion detection system, and a catenary lightning protection system. The work for each new building includes communication and fire protection systems, all supporting utilities, and site work consisting of parking aprons, access drives, and landscaping. The estimated cost of this acquisition is between $6,000,000 and $6,750,000. RFP ISSUE DATE: The Government intends to issue the Request For Proposals (RFP) electronically by posting it on the NAVFAC website, http://esol.navfac.navy.mil., on or about August 03, 2006. A site visit will be held at 1000 hours on August 15, 2006, at Shaw Air force Base, Sumter, SC in Bldg # 218. To obtain Shaw AFB access contact: Gerald Pearson at (803) 895-5005 or email: Gerald.pearson@navy.mil. Proposals will be due around September 01, 2006. The exact date will be stipulated in the RFP. Offerors must register themselves on the Internet at http://esol.navfac.navy.mil. The official plan holders list will be maintained on and may be printed from the web site. Amendments will be posted on the web site for downloading. This will be the only method of distributing amendments; therefore, IT IS THE OFFERORS RESPONSIBILITY TO CHECK THE WEB SITE PERIODICALLY FOR ANY AMENDMENTS TO THIS SOLICITATION. Please note that all contractors and potential contractors must be registered with the Central Contractor Registration (CCR) database with a DUNS number. For instructions on registering with the CCR, please visit their web page at http://www.ccr.gov. For inquiries about Administrative issues, i.e., Proposals Due or Number of Amendments issued, contact John A. Jeffries at 843/820-5904. Technical inquiries prior to Request for Proposals must be submitted in writing 15 days before proposals are due to the address listed above, or emailed to John A. Jeffries, Contract Specialist at john.a.jeffries@navy.mil. Results of proposals will not be available.
 
Place of Performance
Address: Shaw Air Force Base, Sumter, South Carolina
Zip Code: 29152
Country: UNITED STATES
 
Record
SN01100793-W 20060730/060728221312 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.