Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF AUGUST 02, 2006 FBO #1710
SOLICITATION NOTICE

Z -- MAINTAIN HVAC, MULTI BLDGS 1231 AND 1360, AREA F, AVIANO AIR BASE ITALY

Notice Date
7/31/2006
 
Notice Type
Solicitation Notice
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
Department of the Air Force, United States Air Force Europe, 31st Contracting Squadron - Aviano, 31st Contracting Squadron (Aviano) Via Pordenone, 33081 Aviano (PN), ., 33081
 
ZIP Code
33081
 
Solicitation Number
Reference-Number-F1F3B16195A100
 
Description
INTERESTED FIRMS MUST BE REGISTERED TO PERFORM CONSTRUCTION WORK IN THE EUROPEAN COMMUNITY AND MEET THE REQUISITES OF ITALIAN LAW 109 OF 11 FEB 1994 AND SUCCESSFUL SCREENING BY THE ITALIAN MINISTRY OF DEFENSE. FIRMS WISHING TO PARTICIPATE ARE REQUIRED TO E-MAIL THEIR INTEREST TO THE PRIMARY OR ALTERNATE POINT OF CONTACT. ?NOTICE TO OFFERORS: FUNDS ARE NOT PRESENTLY AVAILABLE FOR THIS PROJECT. NO AWARD WILL BE MADE UNDER THIS SOLICITATION UNTIL FUNDS ARE AVAILABLE. THE GOVERNMENT RESERVES THE RIGHT TO CANCEL THIS SOLICITATION, EITHER BEFORE OR AFTER THE CLOSING DATE, WITH NO OBLIGATION TO THE OFFEROR BY THE GOVERNMENT?. OFFER VALIDITY: 30 NOV 06. LE DITTE INTERESSATE ALLA GARA D?APPALTO DEVONO RISPONDERE IN TAL SENSO PER POSTA ELETTRONICA ALLE PERSONE INDICATE NEL PRESENTE AVVISO DI GARA. ?AVVISO: I FONDI PER LA COPERTURA FINANZIARA DI QUESTO PROGETTO NON SONO ATTUALMENTE DISPONIBILI. L?AMMINISTRAZIONE SI RISERVA LA FACOLTA? DI CANCELLARE LA GARA PRIMA O DOPO LA SCADENZA PER LA PRESENTAZIONE DELLE OFFERTE SENZA NESSUN OBBLIGO VERSO L?OFFERENTE DA PARTE DELL?AMMINISTRAZIONE?. VALIDITA? DELL?OFFERTA: 30 NOVEMBRE 2006. MAGNITUDE OF CONSTRUCTION: BETWEEN $100,000.00 AND $250,000.00. ENTITA? DEL PROGETTO: TRA $100,000.00 E $250,000.00. The offeror shall possess DUNS number (web address: www.dnb.com); NCAGE CAGE (NATO Commercial and Government Entity) web address: http//www.dlis.dla.mil/Forms/Form AC135.asp and then offeror shall be registered CCR (Central Contractor Registration) web address: www.ccr.gov and select ?Start new registration?. Le ditte che presentano offerta devono possedere un numero Data Universal Numbering System (DUNS) (indirizzo web: www.dnb.com); NCAGE CAGE (Codice di ente governativo e commerciale) indirizzo web: http//www.dlis.dla.mil/Forms/Form AC135.asp e una volta in possesso dei precedenti codici l?impresa deve registrarsi CCR (Central Contractors Registration) indirizzo web: www.ccr.gov e slezionare ?Inizia nuova registrazione?. SCOPE OF PROJECT AND WORK CONDITIONS TO MAINTAIN HVAC SYSTEM, AT BLDG 1231 AND 1360, AREA F, AVIANO AB, ITALY: The scope of project ASHE 06-1052, MAINTAIN HVAC SYSTEM, BLDG 1231 AND 1360, AVIANO AB ITALY. For Bldg 1231: Replace entire HVAC systems to include compressors, control circuits/wiring, upgrade breaker panel, chilled water coils, pumps, expansion tanks, condenser coils, condenser fan assembly and evaporator coil. Replace all chilled water piping, valves, regulators, temperature and pressure gauges. HVAC system must have primary and backup system. Chilled water lines must be filled with glycol and refrigerant must meet 2010 Italian/USAFE EPA standards. For Bldg. 1360: Remove and dispose of chillers on the roof and replace with new. Replace entire HVAC system to include compressors, control circuits/wiring, upgrade breaker panel, chilled water coils, pumps, expansion tanks, condenser coils, condenser fan assembly and evaporator coil. Replace all chilled water piping, valves, regulators, temperature and pressure gauges. HVAC system must have primary and backup system. Chilled water lines must be filled with glycol and refrigerant must meet 2010 Italian/USAFE EPA standards. SCOPO DEL PROGETTO E CONDIZIONI DEL LAVORO: Lo scopo del progetto ASHE 06-1052, rifare l?impianto di condizionamento degli edifici 1231 e 1360 della Base di Aviano. Edificio 1231: Sostituire l?intero impianto di condizionamento che consiste di: compressori, circuiti oppure impianto di controllo, potenziare quadro interruttori, installare serpentina per acqua fredda, pompe, serbatoio di espansione, bobina di condensa, assemblaggio ventola di condensa e bobina evaporatore. Sostituire tutte le valvole delle tubazioni dell?acqua fredda, regolatori, manometri della temperatura e pressione. Gli impianto dovra? avere controllo primario e del back-up. Nelle tubazioni dell?acqua fredda dovra? essere con glycol e refrigerante 2010. Edificio 1360: Demolire e smaltire dei refrigeranti dal tetto e sostituire con uno nuovo. Sostiture l?intero impianto condizionamento che consiste di: (come per l?edificio 1231).
 
Place of Performance
Address: AVIANO AIR BASE, ITALY
Country: ITALY
 
Record
SN01102260-W 20060802/060731221800 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.