SOLICITATION NOTICE
23 -- TRAILER
- Notice Date
- 8/18/2006
- Notice Type
- Solicitation Notice
- Contracting Office
- N00178 17320 Dahlgren Road Dahlgren, VA
- ZIP Code
- 00000
- Solicitation Number
- N0017806Q2040
- Response Due
- 8/25/2006
- Archive Date
- 10/15/2006
- Description
- The synopsis is being posted to both the Federal Business Opportunities (FBO) page located at http://www.fbo.gov and the Navy Electronic Commerce on Line (NECO) site located at http://www.neco.navy.mil. While it is understood that FBO is a single point of entry for posting of synopsis and solicitations to the internet, NECO is the alternative in case FBO is unavailable. Please feel free to use either site to access the information posted by the Navy Sea Systems Command. This procurement is a small business set-aside. The Naval Surface Warfare Center, Dahlgren Division, intends to purchase one enclosed, box over frame 32 foot tandem axle Trailer. This trailer shall be delivered in turn key form and configured as follows: OVERALL: Box style trailer, Tandem 7000 pound capacity axles, qty of 1 pair of electric brakes per axle, 2-5/16 inch coupler, Breakaway Switch, Trickle charger for deep cycle break-away battery, LED Tail Lights, 3rd Tail Light, qty of 1 pair of Back Up lights, Aluminum Tread Plate on tongue, full trailer width Stoneguard, ATP generator box mounted on tongue LxWxH in inches 44x28x28, Rust Inhibiting Chassis Protection, Tongue Jack w/Sand pad, Below floor spare tire storage, full size Spare Tire mounted on wheel, qty of 4 scissor type stabilizer jacks with 5000 pound capacity; STRUCTURE: exterior walls shall be .030 Smooth Aluminum, exterior roof shall be .050 Smooth Aluminum, roof shall be reinforced with framing 12 inches on center, rear door opening shall measure at least 7 feet 10 inches by 8 feet and shall be fitted with a heavy duty ramp door with a .080 smooth aluminum hinge cover, 3/4 inch plywood floor, aluminum tread plate floor covering, 3/8 inch plywood lined walls and ceiling, 36 inch RV side door with screen, flush lock and fold out steps, ceiling, walls and floors shall be insulated, galvanized under-flooring, framing and wiring for roof AC units, heaters, and vent fans; ELECTRICAL: 100 amp panel box, qty! of 6 four foot double tube two pronged florescent lights with diffuse r, qty of 2 five hundred watt quartz lights with recessed wall switch, qty of 4 exterior GFI outlets, qty of 16 one hundred ten volt GFI wall receptacles, qty of 1 one hundred ten volt wall switch, qty of 2 one hundred ten volt 3 way wall switches, 12 volt fuse panel, qty of 2 twelve volt 3 way wall switches, qty of 4 twelve volt cargo lights, qty of 4 twelve volt quartz loading lights mounted on rear header, qty of 2 twelve volt cigarette lighter plug outlets; HVAC: qty of 2 roof mount AC units 15000 BTU, qty of 2 AC heat strips 5600 BTU, qty of 2 one hundred ten volt fifteen hundred watt wall heaters with blowers, qty of 2 Fan Tastic power roof vents with 12 volt thermostat, qty of 2 Maxxair vent covers, qty of 5 Salem 2 way hinge less vents; INTERIOR: interior floor height shall be no more than 22 inches above road surface, interior ceiling shall be 10 feet high, interior floor shall measure 31 feet six inches long, interior floor width shall be 8 feet wide, qty of 1 aluminum L shaped workbench with stainless steel top running the full width of the trailer by 4 feet including drawers and cabinets overhead and below, qty of 1 two foot by two foot closet with rod, qty of 2 forty eight inch fold down work benches, qty of 20 rope rings recessed in walls, qty of 2 twenty five foot E-Track Tie-down rails recessed in wall, qty of 3 twenty five foot E-Track Tie-down rails recessed in floor, qty of 1 interior mounted ladder with roof access hatch, qty of 1 twenty five foot aluminum I beam in roof; EXTERIOR: qty of 2 eight foot by eight foot roof platforms including 42 inch high fold down rails, qty of 1 exterior mounted roof access ladder, qty of 1 twenty one foot roll out awning, qty of 1 forty five hundred pound capacity twelve volt winch system with remote and winch plate, qty of 1 twenty gallon water tank with 12 volt pump, qty 1 twenty six gallon grey water tank with vent, qty of 1 hand sink, and qty of 1 eight foot air condition curtains. These items will be acquired utilizing Simplified Acquisition Procedures in accordance with FAR Part 13. The closing date is 25 August 2006 ET at 1200, noon. Anticipated Award date is 1 September 2006. All items are to be priced FOB-Destination, Dahlgren, VA. Delivery shall be no more than 12 weeks ARO from date of order placement. THE GOVERNMENT WILL NOT ISSUE A WRITTEN REQUEST FOR QUOTATION AS ALL ITEMS ARE IDENTIFIED IN THIS NOTICE. Electronic quote submission is encouraged at DLGR_NSWC_XDS12@navy.mil, but the quote may also be faxed at (540) 653-4089 or delivered to the Naval Surface Warfare Center, Dahlgren Division, Attn: XDS128, Bldg. 183, Room 104, 17320 Dahlgren Rd., Dahlgren, VA 22448-5100.
- Record
- SN01119865-W 20060820/060818221943 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |