MODIFICATION
23 -- Crash Recovery Scene Response Trailer with custom options
- Notice Date
- 8/18/2006
- Notice Type
- Modification
- NAICS
- 336212
— Truck Trailer Manufacturing
- Contracting Office
- Department of the Air Force, Air Force Materiel Command, AFFTC - AF Flight Test Center, 5 S WOLFE AVE, Edwards AFB, CA, 93524-1185
- ZIP Code
- 93524-1185
- Solicitation Number
- Reference-Number-F1S1AB6118B002
- Response Due
- 7/7/2006
- Archive Date
- 12/12/2006
- Point of Contact
- Mary Uptergrove, Contracting Officer, Phone 661-275-2538, Fax null,
- E-Mail Address
-
mary.uptergrove@edwards.af.mil
- Small Business Set-Aside
- Total Small Business
- Description
- This is a combined synopsis/solicitation for commercial items prepared IAW the format in FAR Subpart 12.6 as supplemented with additional information included in this notice. This announcement constitutes the only solicitation. Quotes are being requested and a written solicitation will not be issued. This is a request for quotation (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 200509 and DFARs Change Notice (DCN) 20060321. Standard Industrial Classification (SIC) code is 3715 and the size standard is 500 employees. NAICS is 336212. This acquisition is a Small Business Set-Aside. This acquisition is for Brand Name or equal items only. Edwards Air Force Base, CA is seeking to purchase a Crash Recovery Trailer with custom options, Quantity, One Each, in support of the 412th MXS/MSMAPA program for crash recovery missions. The equipment needs to be equal to the specification listed to meet the form, fit, and function of mission requirement. 412th MXS/MXMAPI Crash Recovery Trailer Specifications: Dimensions: Length: 53- 0 O/A Width: 8- 6 O/A Height: 13- 6 Front to drop: 11 0 Drop to rear: 420 5th Wheel Height: 47-1/2 Floor Height: Front: 54 Rear: 42 Frame Drop:12 General Specifications: Suspension: Two air ride suspension (Hendrickson HT 190U) Tires: Eight 255-70R-19.5 Wheels: Eight: polished Aluminum outers, brushed aluminum inner Brakes: Full air, anti-lock (Meritor WABCO) Frame: Full length W-14 steel wide flange H-beam on 40 centers Top rail: Aluminum extrusion Exterior skin: 100% 0.090 smooth aluminum with no visible exterior fasteners, and 100% perimeter mechanical fastening. Roof skin: 0.040 aluminum-one piece construction. Expandable Sect: 100% Aluminum construction. Floor Frame: 100% Aluminum construction. Landing gear: Hydraulic at drop. Leveling gear: Hydraulic between tandem. Interior sub walls: 3/8 interior-grade lite plywood. Insulation: Walls & ceiling; 2-3 Polyurethane spray foam. R- factor of 6.6 per inch. Undercoated: Techtyl, petroleum based. Sub floor: 3/4 marine-grade lite plywood. Rear doors: Rear Swing Doors (for handicap lift access). Rear freight doors made of aluminum with recessed hardware and a mirror finished Side doors: four (4) 36 x 80 aluminum frame, glass lites, on each expandable sections end wall. Stairs & Landings: -Two (2) aluminum treadbrite construction step and landing assemblies with stainless steel handrails. One (1) one ladder style step assembly only for access to 5th wheel area. Belly box storage Full Width belly storage 5-0 rear of tandem and 24-0 ahead of tandem. Painted aluminum configuration with #8 mirror finish stainless steel contour Gas Assist shocks for above 3 Slide out drawers on curbside Exterior finish: Construction: Rivetless, smooth aluminum exterior skin panel construction, with Full perimeter, per-panel mechanical fasteners, in addition to state of the art adhesive bonded to upright trailer frame posts. Paint: PPG Delfleet Commercial Fleet grade epoxy coating. Sand, prep and paint any one (1) solid color. Graphics: 3M Premium Grade Vinyl Graphics as per supplied artwork. 10K custom exterior graphics budget Lightning: 100% LED Exterior Lighting and all required Federal Highway lighting and reflective markings Custom Awning: Construction: Custom built, Anodized Aluminum frame with Fire Retardant Dacron fabric. 50 x 20 Wrap around vinyl skirt that conceals the whole underside of the trailer and expandable sections Nose section: Interior Width: Approximately 8-2 with unfinished interior 8-0 typical finished). Interior Height: Approximately 8-8 with unfinished interior (7-6 typical finished). Wall Finish: .050 aluminum skin Ceiling Finish: Drop ceiling, white 2 x 2 acoustic tiles, white ceiling grid. Floor Finish: raised rubber dot -Lonseal. Main Section: Length: Approximately 37-0 with unfinished interior. Width: Approximately 8-2 with unfinished interior (8-0 typical finished). Height: Approximately 10-0 with unfinished interior (8-9 typical finished). Interior Finish: Injected urethane insulation for ceiling, doors, and walls with an R- factor of 6.6 per inch. Plywood walls 3/4 plywood floor Expandable Sections : O/A Length: 28-0 Height: 7- 0 and 7 6 Expansion: 84 per side via heavy duty self contained outrigger style telescopic slide tube assembly, maximum two per expandable section 22.5 trailer width fully expanded Bi-fold floor assemblies to create air tightness No exterior floor popping cylinders Floors work with same button on control for expandable section Step-up and cable or winch activated style not acceptable Two lower slide assemblies per expandable sections. Low friction with roller assemblies No upper cylinders used on expandable assemblies Expandable section operates on a 12VDC and 220 VAC with hand held pendant Walls finished in 3/8 lite plywood, finished with fabric wrapped sound board. Ceiling finished with white pedestal 2x2 dropped ceiling Floor finished in commercial grade Lonseal or equal rubber flooring Kingpin: Kingpin Radius: 78-1/2 Kingpin Setback: 36 King Pin to Axles: 480 to center of rear axles Electrical/Lighting: Martin 50 KW Diesel Generator with standard housing Set of Spare Filters Generator installed in nose section of trailer Auto Louvers that open and close automatically with Generator operation 50 gallon fuel tank installed under trailer Remote Start for generator set Soundproofing for generator housing 110v shore power/100 amp, (100 amp panel, breaker, phase mtr) 100 amp transfer switch for onboard generator/shore power 50 foot shore power cable with ends 4 GFI exterior connectors, 2 per side, front and back, weatherproof covers 14 overhead lights 12 interior outlets 2 switches front and back Any required wiring for integration of electrical components 6 Halogen scene lighting, 300 watt recessed, 3 per side Rear Strobe Assembly, 2 in upper front corners and 2 upper rear corners Rear mounted Floodlights Emergency 12 volt lighting for 2 lighted EXIT signs Mechanical: 2 Five Ton Bard HVAC wall mount unit capable of 56,500 BTU's/9Kw heat HVAC start up certification 2 electric thermostats with full electronic control 2 50' stat wires Install ductwork fastened to roof bows 12 grills, plastic or aluminum Air Compressor 5 HP/50 Gallon, 130 CFM@120 PSI Air Compressor outlet terminated in wall with quick coupler Accessories: 3 Fire Extinguishers, dry chemical Lift gate 4000 pounds max load, electric/hydraulic operation, tucks under rear of trailer Tie Down System; Aircraft Tie Down in 2 strips routed in the floor 24" from the wall 30 Double Stud Rings for above Powered Accessories; 2 Milwaukee Power Leveling Gear (independent 4 post leveling gear hydraulically operated (push button) per pair mounted) 4 aluminum Landing Gear Pads for added load/weight distribution when off road/ground support Exterior/Paint; 10K custom exterior graphics budget Delivery FOB Destination Edwards AFB CA 93524. Delivery is 150 - 180 DARO. Brand Name or Equal : 1. The 412 MXS/MXMAPI request the Brand Name or Equal Purchase of a Kentucky Trailer/Kentucky Trailer Industries 53 foot drop frame trailer to support crash recovery operations at Edwards Air Force Base. 2. The trailer will be equipped with 100% of crash recovery equipment used to support 26 different weapon systems with full crash recovery capability. This trailer must be designed and constructed to be towed across unapproved roadways; the trailer will be required to travel on and off road in conditions that normal vehicles would find difficult to navigate. They developed the "drop frame" trailer systems, which have become a staple in the moving industry Kentucky trailers drop frame systems represent significant advances in performance over comparable straight trailers. The salient functional characteristics of Kentucky Trailers/Kentucky Trailer Industries trailers are essential to the 412 MXS/MXMAPI Crash Recovery operations as follows: Kentucky Trailers/Kentucky Trailer Industries trailers are built to our specifications. Kentucky Trailers/Kentucky Trailer Industries trailers drop frame trailers typically hold 5 - 25 percent more volume than comparable straight trailers which allow us to consolidate 26 different aircrafts related equipment into one location for better equipment accountability. The trailer requested will free up essential personnel and equipment needed to perform other functions during aircraft recovery operations. 3. Kentucky Trailer/Kentucky Trailer Industries is the only known corporation that can build a crash recovery trailer to meet our rigid specifications. Other trailer builders are more suited towards building vehicle trailers that are designed for on-road applications. Our unique requirement to recover aircraft in locations where rough terrain is the norm rather than the exception require us the have the best possible design and construction possible. 4. As an Aircraft Repair Flight practice, we try to avoid Brand Name or Equal situations as much as possible. There are times however, when due to mission requirements and the lack of companies that provide unique aerospace support, we are sometimes forced to use the Brand Name or Equal process. We will continue to do our best to try and avoid these situations in the future. Interested parties who believe they can meet all the requirements for the one (1) Crash Recovery Scene Trailer with custom options described in this synopsis are invited to submit in writing complete quote including delivery FOB destination Edwards AFB CA 93524. Offerors are required to submit with their quote enough information for the Government to evaluate the minimum requirements detailed in this synopsis. Offerors are required to submit their quote in the same order and format as the specifications are cited in posting. CONTRACTORS MUST COMPLY WITH FAR 52.204-7 CENTRAL CONTRACTOR REGISTRATION (OCT 2003) AND DFARS 252.204-7004, ALTERNATE A (NOV 2003). INTERESTED CONTRACTORS CAN ACCESS THE CLAUSEs BY INTERNET URL: http://farsite.hill.af.mil. TO REGISTER WITH THE CCR, GO TO URL: http://www.ccr.gov/ . ONLINE REPRESENTATIONS AND CERTIFICATIONS APPLICATION (ORCA) MUST BE COMPLETED.USE OF ONLINE REPRESENTATIONS AND CERTIFICATIONS APPLICATION (ORCA) BECAME MANDATORY 1 JANUARY 2005. CONTRACTORS CAN ACCESS ORCA THROUGH CCR BY INTERNET URL: http://www.ccr.gov/ . The following provisions and clauses apply: Provision 52.212-1, Instructions to Offerors--Commercial; Clause 52.212-2 Evaluation-Commercial Items, the following factor shall be used to evaluate offers: technically acceptable to the Government lowest price offer; clause 52.212-4, Contract Terms and Conditions--Commercial Items; clause 52.212-5, Contract Terms and Conditions Required to Implement Statutes Or Executive Orders--Commercial Items (to include: 52.222-26, Equal Opportunity; 52.222-35, Affirmative Action for Special Disabled and Vietnam Era Veterans; 52.222-36, Affirmative Action for Handicapped Workers; 52.222-37, Employment Reports on Special Disabled Veterans and Veterans of the Vietnam Era); Clause 52.225-3 Buy American Act North American Free Trade Agreement; Clause 52.232-33 Mandatory information for electronic funds transfer payment. The following DFARs clauses apply to this acquisition: Clause 252.212-7001, Contract Terms and Conditions Required to Implement Statutes or Executive Orders Applicable to Defense Acquisition of Commercial Items (Mar 1998); 252.225-7001 Buy American Act and Balance of Payment Program; Clause 252.211-7003, Unit Identification Clause 252.225-7036, North American Free Trade Agreement Implement Act; Clause 5353.223-9000, Elimination of Use of Class I Ozone Depleting Materials; Ombudsman Clause 5352.201-9101. Offers are due at the Air Force Flight Test Center, Directorate of Contracting, 5 South Wolfe Avenue, Edwards AFB, CA, 93524, not later than Close of Business (COB) 24 Aug 2006 at 4 pm PST. E-mailed quote submissions are acceptable. E-mail address: mary.uptergrove@edwards.af.mil. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (18-AUG-2006); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link to FedBizOpps document.
(http://www.fbo.gov/spg/USAF/AFMC/AFFTC/Reference-Number-F1S1AB6118B002/listing.html)
- Place of Performance
- Address: Edwards AFB CA
- Zip Code: 93524
- Zip Code: 93524
- Record
- SN01120240-F 20060820/060818230237 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |