Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF AUGUST 30, 2006 FBO #1738
MODIFICATION

66 -- METTLER DL77 AUTOMATIC TITRATOR OR EQUAL

Notice Date
8/28/2006
 
Notice Type
Modification
 
Contracting Office
3610 Collins Ferry Road (MS-I07) P.O. Box 880 Morgantown, WV
 
ZIP Code
00000
 
Solicitation Number
DE-RQ26-06NT00794
 
Response Due
8/31/2006
 
Archive Date
2/28/2007
 
Small Business Set-Aside
N/A
 
Description
THE FOLLOWING EQUIPMENT IS TO BE PURCHASED IN ADDITION TO THE METTLER DL77 AUTOMATIC TITRATOR. RONDO60: 1 MULTI-FUNCITION SAMPLE TRANSPORT - 20 SAMLE CAPACITY, INCLUDES ONE TOWER, ONE RINSE PUMP, 20 BREAKERS, DISPENSING TUBES, POWER SUPPLY AND DL5X/7X CONNECTING CASBLE. CAN SUPPORT A 2ND TOWER FOR ADDITIONAL AUTOMATION, AND CAN FULLY AUTOMATE VOLUMETRIC KARL DISHCER AND COD ANAYLSES. THE NEED IS FOR AN AUTOMATIC TITRATOR, METTLER DL77 OR EQUILVALENT, WITH AUTO-SAMPLING CAPABILITIES (20 SAMPLE MINIMUM). THE TITRATOR MUST BE CAPABLE OF ACID/BASE, FULLY AUTOMATED KARL FISHCER, FULLY AUTOMATED COD, PRECIPITATION, REDOX, COMPLEXOMETRIC, AND PHOTOMETRIC TITRATIONS AS WELL AS PH STAT, PH, AND ION SELECTIVE MEASUREMENTS. THE UNIT MUST BE CAPABLE OF PERFORMING TWO SIMULTANEOUS TITRATIONS. THE TIEM INTERVAL FOR PH STAT MEASUREMENTS MUST BE ADJUSTABLE WITH A MAXIMUM OF NOT LESS THAT 2 DAYS (48 REAGENTS, STANDARDS, ETC.) NECESSARY FOR ACID/BASE AND PH STAT ANALYSES (SINGLE CHEMICALS: REAGENTS, STANDARDS, ETC.) NECESSARY FOR ACID/BASE AND PH STAT ANALYSES (SINGLE BURETTE OPERATION) FOR EXAMPLE, SAMPLE HOLDERS, BURETTE DRIVES, BURETTES, AND PH ELECTRODES MUST BE INLCUDED THE ONLY EXCEPTION IS THAT A PC, IF NEEDED, IS NOT TO BE INCLUDED. THE UNIT MUST BE CAPABLE OF 2-DRIVE OPERATION FOR MORE COMPLEX ANALYSES. THE UNIT MUST BE EQUIPPED WITH A STIRRER OR OTHER AGITATION DEVICE FOR THE PROPER ANALYSES OF SOLID MATERIALS SUCH AS, BUT NOT LIMITED TO, THE ANALYSES OF ALKALINITY IN COAL COMBUSTION FLY ASH. THE TITRATOR MUST BE CAPABLE OF PERFORMING THE STANDARD TITRATION CALCULATIONS SUCH AS END POINT, EQUIVALENCE POINT, AND BICARBONATE AND TOTAL ALKALINITIES. THE AUTO SAMPLER MUST BE INCLUDED ALONG WITH AL TUBING, CABLES, SOFTWARE OR OTHER PARTS NEEDED FOR IMMEDIATE INSTALLATION AND OPERATION. REPORTS MUST PROVIDE PLITS FOR POST-RUN EVALUATION, NOT JUST A NUMERIC ASSAY. FOR EXAMPLE, AN ACID/BASE TITRATION REPORT MUST BE CAPABLE OF GENERATING A PH-VOLUME PLOT NOT JUST A NUMBERIC END POINT. DATA MUST BE EXPORTABLE IN EXCEL-ACCESSIBLE FORMAT FOR ALTERNATIVE/ADDITIONAL POST-RUN CALCULATIONS AND PLOTS. REPORTS OR PARTS OF THEM, FOR EXAMPLE A TITRATION PLOT, MUST BE AVAILABLE FOR INCORPORATION INTO OTHER REPORTS, SUCH AS JOURNAL ARTICLES OR MANUSCRIPTS, USING STANDARD PC OPERATIONS SUCH AS CUT-AND-PASTE. IF INSTRUMENT CONTROL, CALCULATIONS, AND/OR REPORT GENERATION IS DONE UNDER COMPUTER CONTROL, THE SOFTWARE IS TO BE INCLUDED BUT NOT THE COMPUTER. THE COMPUTER NECESSARY FOR PROPER OPERATION SHALL NOT BE OTHER THAN A PC RUNNING WINDOWS XP. INSTALLATION AND TRAINING ARE TO BE INCLUDED.
 
Web Link
Click here for further details regarding this notice.
(https://e-center.doe.gov/iips/busopor.nsf/UNID/D6186D764967722D852571D800647659?OpenDocument)
 
Record
SN01127259-W 20060830/060828220305 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.