MODIFICATION

58 -- Security camera and monitor installation

Notice Date
9/6/2006
 
Notice Type
Modification
 
NAICS
561621 — Security Systems Services (except Locksmiths)
 
Contracting Office
Department of the Air Force, Air Force Space Command, 21CONS (Bldg 982), Base Support Flight 700 Suffolk Street, STE 1200, Peterson AFB, CO, 80914-1200
 
ZIP Code
80914-1200
 
Solicitation Number
FA2517-06-T-6080
 
Response Due
9/13/2006
 
Archive Date
9/28/2006
 
Point of Contact
David Moreno, Contracting Specialist, Phone 719-556-5395, Fax 719-556-4321,
 
E-Mail Address
david.moreno@peterson.af.mil
 
Small Business Set-Aside
Total Small Business
 
Description
COMBINED SYNOPSIS/SOLICITATION Camera and Monitor installation for Building 2025 (I) This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. (II) This solicitation is issued as a request for quote (RFQ). Submit written quote (to include price quote for all CLINS) on RFQ reference number FA2517-06-T-6080. (III) This solicitation document and incorporated provisions and clauses are those in effect through Fed Acquisition Circular 2005-12. (IV) This solicitation is a Small Business set-aside. NAICS 561621, small size standard is $11.5 million. (V) This combined synopsis/solicitation is for the following commercial items: CLIN 0001 Materials and Equipment-The Contractor shall provide all associated materials required to accomplish the project in accordance with Statement of Work. CLIN 0002 Non-Personal Service- The contractor shall provide all supervision, management and labor necessary to complete installation in accordance with the statement of work. (VI) Description of requirement: Statement of Work for Camera and Monitor installation for Building 2025 Overview; Contractor shall provide all supervision, labor, transportation, equipment, and tools to install seven cameras on the second floor of building 2025, add a second sixteen channel digital video recorder to existing CCTV system and install a 50 inch plasma screen as monitor. This installation will be an addition to the existing CCTV system at building 2025. The contractor will provide and install seven Honeywell five inch fixed dome cameras (5" Stationary Dome Camera KD5 series, or equal/please see camera specification) at designated locations in Bldg 2025, hallways on second floor area (no specific rooms) and Room 101. The DVR currently in place will remain in place and a new DVR will be installed to record the seven new cameras. The contractor will also provide conduit installation on this project. Conduit will be installed from each camera to the DVR located in room 101. New cable shall be used in the conduit and pulled to all cameras. The cameras above may be identified by brand name; however, equivalent parts of other brands can be substituted. Part numbers and brands shall be identified in contractor quotes. All cabling shall be in conduit and concealed in walls or above the grid ceiling wherever possible. All programming and testing is required for full functionality by the contractor. Contractor agrees to complete all work within 40 days after date of contract award. Contractor shall provide one-year warranty on all material and workmanship related to this contract beginning with the day after the project has been completed. All Work shall be performed in accordance to National Electric Code and industry practices. Camera Specifications ELECTRICAL (HOUSING) Input Voltage 24V ac MECHANICAL (HOUSING) Angular Travel: Horizontal ? 180? Vertical: Dome 0 to 90? up Roll 360? Camera Mounting: Universal mount attached to yoke assembly will accommodate CS-mount & fixed lens board cameras Cable Entry: Dome Conduit knock-out in standard 4 x 4 in. electrical box Cable Connection: Terminal strip & BNC at top of upper housing Construction: Back Can/Box: Dome Plenum-rated steel (standard 4 x 4 in. electrical box) Upper Housing UL-approved, flame-retardant ABS plastic Lower Housing Optically graded acrylic, distortion free Finish: Back Can/Box: Dome Standard galvanized steel Lower Housing: Dome Smoked, clear with liner Trim Ring White, black Dimensions See drawings Weight Dome 1.0 lb. (w/o 4 x 4 in. back box) GENERAL (HOUSING) Optical Losses: Clear/Liner Virtually no light loss Smoked Equivalent F-stop 1.0 ? 15% Filtration Neutral density Environment Indoor Regulatory Agencies/ Approvals: CE ELECTRICAL (CAMERA) Specification: High Resolution Color Image Sensor 1/3" interline transfer CCD (Sony chip set) Active Pixels 768H x 494V Horiz. Resolution 470 lines Min Scene Illum. 0.9 Lux (F1.2, 50IRE) NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (06-SEP-2006); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link to FedBizOpps document.
(http://www.fbo.gov/spg/USAF/AFSC/21CONSb984/FA2517-06-T-6080/listing.html)
 
Place of Performance
Address: PETERSON AFB
Zip Code: 80916
Country: UNITED STATES
 
Record
SN01135956-F 20060908/060906232911 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.