H -- Service agreement for Grounding, Lightning/Static Protection System Inspections.
- Notice Date
- 9/7/2006
- Notice Type
- Solicitation Notice
- NAICS
- 238210
— Electrical Contractors
- Contracting Office
- 147 FW/MSC, Bldg 1258, Ellington Field, 14657 Sneider Street, Houston, TX 77034-5586
- ZIP Code
- 77034-5586
- Solicitation Number
- W912L106R5005
- Response Due
- 9/19/2006
- Archive Date
- 11/18/2006
- Small Business Set-Aside
- Total Small Business
- Description
- COMBINE/SYNOPSIS SOLICITATION (1). This is a combined synopsis/solicitation for commercial items in accordance with the format in FAR Subpart 12.6 as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are b eing requested and a written solicitation will not be issued. (2). Request for Proposal (RFP) W912LA-06-R-5005 is a combined synopsis/solicitation for commercial items. This combined synopsis/solicitation is issued as a RFP. Submit written offers only, oral offers will not be accepted. All firms or individuals resp onding must be registered with the Central Contractor Registration (CCR) as prescribed in DFARS 252.204-7004. CCR can be accessed at www.ccr.gov or by calling 1-888-227-2423. NOTE: CCR registration must be completed prior to contract award. (3). This combined synopsis/solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Regulation and the Department of Defense FAR Supplement dates 1 July 2006. It is the contractors responsibility to be familiar with applicable clauses and provisions. Clauses and provisions can be found at http://farsite.hill.af.mil/ (4). This procurement is being issued as 100% Small Business Set-Aside. The North American Industrial Classification Standard (NAICS) is 541350. The Small Business Size Standard is as follows: $6.5 Million. (5). Wage Determination used for this announcement is No: 05-2515 REV (01) AREA: TX, HOUSTON. Reference location http://www.wdol.gov/sca.aspx#0 (6) STATEMENT OF WORK (SOW): CLIN (0001) STATEMENT OF WORK Service Agreement for Grounding, Lightning/Static Protection System Inspections FY07. Location: Buildings 1193, 1397, 1398, 1404, 1405, 1250, 1382,1359, 1412, 1413, 1394, 1254, 1296, 1142, POL Facilities, all 147th FW ANG Aircraft Ramp and Parking areas Work Order # 20061300 Reference: NFPA 70 (NEC), AFI 32-1065 (Civil Engineering Grounding Systems, Oct 98) and AFMAN 91-201 (Explosives Safety Standards,Oct 2001, chapter 5) Scope: Contractor to provide all parts, materials, labor, transportation and equipment necessary to inspect and test for equipment grounding, lightning protection, and static protection for the following: Inspection description and frequency requirements: a. Visual inspection and resistance check of facility grounds (25-ohm max). Frequency: Once during FY 07. b. Visual inspection of lightning protection system. Frequency: Once Nov 06. c. Conductive floor grounding check. The resistance between the ground and the wearer must not exceed 1,000,000 ohms (the total resistance of conductive shoes on a person, plus the resistance of floor to ground). Frequency: Twice during FY 07 (Nov/May). d. Resistance check on lightning protection system (25 ohms max except Ground Loop System). Frequency: Once Nov 06. e. Continuity checks on air terminals, bonds, and conductors (1 ohm). Frequency: Once - Nov 06. f. Static bus bar continuity to ground/check grounding points to bus bar for continuity (1 ohm). Frequency: Once Nov 06 g. POL requirement is only required the following: Visual inspection and check tightness on ground conductors. Frequency: Quarterly - Nov 06, Feb 07, May 07, and Aug 07 Inspectors and testers must compile and maintain records of their inspections to include: a. A sketch of the grounding and lightning protection system showing test points, and where the services enter the facility. Sketch should also show the location of the probes during the ground resistance test. Separate sketches are suggested for static, earth ground, and lightning protection systems on large complex facilities. b. Date actions were performed. c. Inspectors or testers name. d. General condition of air terminals, conductors, and other components. e. Security of attachment for conductors and components. f. Resistance measurements of the various parts of the ground terminal system. g. Discrepancies noted and corrective actions taken h. Contractor will provide the above items to the Base Civil Engineer Grounding resistance, continuity tests, and visual inspections testing requirements: a. Instruments must be able to measure 10 ohms + or 10 percent for ground resistance tests, and 1 ohm + or for continuity testing. Only instruments designed specifically for earth-ground systems are acceptable for ground resistance testing. Earth gro und resistance should be less than 25 ohms unless specified different in this document. Visual inspections of lightning protection systems: Note: Inspect all visible parts of the systems. Pulling or tugging on conductors and connections to insure soundness is a necessary part of these inspections, but be careful not to damage the system in the process. Visual/physical inspections must deter mine if: a. The system is in good repair. b. There are loose connections that might cause high resistance joints. c. Corrosion or vibration has weakened any part of the system. d. Down conductors, roof conductors, and ground terminals are intact. e. Braided bonding wires are excessively frayed (cross sectional area reduced by half) f. Ground wires on lightning protection masts are damaged by lawn mowers or other equipment. g. Additions or alterations to the protected structure require additional protection. h. Surge suppression (over voltage) devices appear damaged i. The system complies with applicable sections of NFPA 780, Standard for the Installation of Lightning Protection Systems Visual inspection of facility grounds. a. Inspect all visible and accessible parts of the system. b. Determine if they are in good condition and the installation meets NEC requirements. Typical items to check: 1. The system is in good repair. 2. There are no loose connections. 3. The system neutral is grounded at the service entrance (this includes the connection to the grounding electrode). 4. Separately derived systems are properly grounded. 5. Flashover protection is installed on insulating fittings on underground metallic pipelines entering the facility. 6. Grounding systems within the facility are bonded together at ground level or below. END SOW (7). An organized site visit has been scheduled for September 13, 2006 at 9:00 am. Participants will meet at-- 147 Base Contracting Office Building 1258 Room 122 14657 Sneider Street Houston, Texas 77034 POC: TSgt Denise Bailey (281) 929-2305 (8). FOB-Destination for delivery to: 147 CES, Attn: Major Matthew Allinson, 14657 Sneider Street, Houston, Texas 77034-5586. Delivery schedule is outlined in the Statement of Work. Responsibility and Inspection: Unless otherwise specified in the contrac t or purchase order, the supplier is responsible for the performance of all inspection requirements and Quality Control (QC). (9). The Government will award a firm-fixed price contract resulting from this combined synopsis/solicitation to the responsible offeror whose offer conforming to the synopsis/solicitation will be most advantageous to the Government, price and other fact ors considered. Award shall be based on Best Value to the Government. Best value can include but is not limited to price, delivery date, past performance, and technical capability. (10). The following provisions and clauses apply to this acquisition: FAR 52.204-7 Central Contractor Registration; FAR 52.212-1 Instructions to Offerors - Commercial Items; FAR 52.212-3 Offeror Representations and Certifications Commercial Items Clause is incorporated by Full Text. Offerors are reminded to include a completed copy of the provision at 52.212-3 with submitted offers, or go online and activate the online reps and certifications application @ http://www.bpn.gov/orca/. Complete only paragraph (j) of this provision if the annual representations and certifi cates have been completed electronically. FAR 52.212-4 Contract Terms and Conditions-Commercial Items; FAR 52.212-5 Contract Terms and Conditions required to implement Statutes or Executive Orders Commercial items Clause is incorporated by Full Text; FAR 52.219-6 Notice of Total Small Business Aside; FAR 52.222-3 Convict Labor; FAR 52.222-19 Child Labor-Cooperation with Authorities and Remedies; FAR 52.222-21 Prohibition of Segregated Facilities; FAR 52.222-26 Equal Opportunity; FAR 52.222-36 Affirmative Action for Workers with Disabilities; FAR 52.222-41 Service Contract Act of 1965; FAR 52.225-1 Buy American Act - Supplies; FAR 52.225-13 Restriction on Certain Foreign Purchases; FAR 52.232-18 Availability of Funds; FAR 52.232-33 Payment by Electronic Funds Transfer- Central Contractor Registration (CCR); FAR 52.236-27 Site Visit Construction ALT I (See (5)); FAR 52.252-2 Clauses Incorporated by Reference; DFARS 252.204- 7004 Alt A Required Central Contractor Registration (NOV 2003); DFARS 252.212-7001, Contract Terms and Conditions Required to Implement Statutes or Executive Orders Applicable to Defense Acquisitions of Commercial Items (MAR 2006); DFARS 252.232-7003 Electronic Submission of Payment Requests; DFARS 252.246-7000 Material Inspection and Receiving Report; (11). RFP must be emailed to denise.bailey@txelli.ang.af.mil , or faxed to (281) 929-2748 by the closing date of 19 September 2006 at 0900. If additional information is needed regarding this solicitation contact TSgt Denise Bailey at (281) 929-2305. Col lect calls will not be accepted.
- Place of Performance
- Address: 147 FW/MSC Bldg 1258, Ellington Field, 14657 Sneider Street Houston TX
- Zip Code: 77034-5586
- Country: US
- Zip Code: 77034-5586
- Record
- SN01136642-W 20060909/060907221330 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |