Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF SEPTEMBER 13, 2006 FBO #1752
MODIFICATION

58 -- Bi-directional Amplifier System

Notice Date
9/11/2006
 
Notice Type
Modification
 
NAICS
334220 — Radio and Television Broadcasting and Wireless Communications Equipment Manufacturing
 
Contracting Office
Department of the Air Force, Air Force Space Command, 460 CONS / LGC, 460 CONS / LGC, 510 S. Aspen St. (MS 92) Bldg 1030, Buckley AFB, CO, 80011-9551
 
ZIP Code
80011-9551
 
Solicitation Number
FA2543-06-Q-0022
 
Response Due
9/15/2006
 
Archive Date
9/30/2006
 
Small Business Set-Aside
Total Small Business
 
Description
AMENDED TO CHANGE Question Marks BACK TO THE ORIGINAL (CORRECTED) CHARCTERS: This is a combined synopsis/solicitation, FA2543-06-Q-0022, for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. Buckley Air Force Base, CO has a requirement to provide and install within 30 days of contract award a complete turn-key bi-directional amplifier system to Building 1, AAFES/BX Building, Buckley Air Force Base (Aurora), Colorado 80011, to include a standard manufacture warranty or a 1-year warranty in accordance with the Statement of Work below. (Contract Line Item Number (CLIN) 0001). FOB Destination. CLIN 0001 has a unit of issue Job (Each), a Quantity of 0001, Unit Price and Extended Price shall be proposed by the offeror. Work schedule and number of days shall be proposed by offeror: Proposed Number of Days _______ (30 days or less), Proposed Schedule Timeline (______ through _____ (days of the week) and _____ to _____ hours (times of the day)). The RFQ will close on 15 September 2006 with an anticipated award date of or around 22 September 2006. A site visit will be conducted on 11 September 2006 at 10:00 AM MDT. All attendees must submit a request to attend on company's letterhead with the full name (first, last and middle initial) of each person attending no later than 8 September 2006 at 3:00 PM MDT. The proposed requirement will be a 100% Small Business Set-Aside (Numbered Note 1). All responsible sources may submit a proposal, which shall be considered by the agency. This acquisition will be accomplished utilizing FAR Parts 12. The resultant contract will be a Firm-Fixed price type contract. The basis of the award will be the based on the compliance of this notice, the Statement of Work and price. In addition the offeror shall follow instructions at FAR Clause 52.212-3 Alt I for submitting Representation and Certification. The online Representation and Certification Application (ORCA) may be found at internet site: http://orca.bpn.gov. Potential contractors must be registered in the Central Contractor Registry to be eligible for award. (See Internet site: http://www.ccr.gov/) The awardee will be required to submit their invoice via WAWF (See Internet Site: http://www.wawftraining.com. When the solicitation is posted, it is imperative interested parties review this site frequently for any updates/amendments. By submission of an offer, the offeror acknowledges the requirement that a prospective awardee must be registered in the Central Contractor Registration (CCR) database prior to award, during performance, and through final payment of any contract resulting form this solicitation. Lack of registration in the CCR database will make an offeror ineligible for award. North American Industrial Classification System Code 334220 and size standard of 750 employees. No paper copies will be issued. 5352.201-9101 OMBUDSMAN fill-in; MAJCOM OMBUDSMEN, HQ AFSPC/A7K, 150 Vandenberg St., Suite 1105, Peterson Air Force Base, Colorado, 80914-4350, phone: 719-554-5250, fax: 719-554-5299, email: a7k.wf@afspc.af.mil. The following provisions and clauses are incorporated by reference and are in effect at this date. FAC 2005-12 and DCN 20060814: 52.212-1, Instruction to Offerors - Commercial Items 52.212-3 Alt I, Offerors Representations and Commercial Items applies. Offeror shall complete a copy of the provision 52.212-3, Alt I or complete the annual representation and certifications (See the first paragraph on the clause 52.212-3. 52.212-4, Contract Terms and Conditions, Commercial Items 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders (DEV) 52.219-9, Notice of Total Small Business Set-Aside 52.223-5, Pollution Prevention and Right-to-Know Information 52.228-5, Insurance - Work on a Government Installation 52.232-33, Payment by Electronic Funds Trasfer-Central Contractor Registration 52.237-1, Site Visit 52.237-2, Protection of Government Buildings, Equipment and Vegetation 52.245-2, Government Property 52.252.6, Authorized Deviations in Clauses, fill-in Department of Defense Federal Acquisition Regulation, Chapter 2 52.252-1 and 52.252-2 the fill-in is a follows: http://farsite.hill.af.mil/ 52.204-9, Personal Identity Verification of Contractor Personnel 252.204-7004 Alt A, Required Central Contractor Registration 252.212-7001, Contract Terms and conditions required to implement statutes etc., (DEV) 252.225-7036, Buy American Act-Free Trade Agreements-Balance of Payments Program 252.232-7003, Electronic Submission of Payment Requests 5352.223-9001, Health and Safety on Government Installation 5352.242-9000, Contractor Access to Air Force Installation Questions may be emailed or faxed. Email is the preferred method of receipt. Email: jacqueline.carter@buckley.af.mil and attila.kovacs@buckley.af.mil Facsimile: (720) 847-6443, Commercial: Jacqueline Carter (720) 847-6677 and Attila Kovacs (720) 847-9952 All quotations shall include the following information: Company's complete mailing and remittance address, discounts for prompt payment, if any (e.g. 1% 10 days), the company's CAGE Code, DUNS & Bradstreet number, and Taxpayer ID number, expiration of quote. Quotes must be valid for a period no less than 60 days. The government will not reimburse the contractor for any monies spent to provide the quotation. Quotes are due no later than 12:00 PM MDT, 15 September 2006. STATEMENT OF WORK (SOW), 23 August 2006 Bi-Directional Amplifier (BDA) Building 1 (AAFES) Buckley Air Force Base 1. Description of Services. Non-personal. This Statement of Work (SOW) defines the actions for the Contractor to provide and install a complete turn-key BDA system for Building 1, AAFES, Buckley Air Force Base, Colorado 80011. In order for this requirment to be considered complete it must conform to Motorola R56 Installation Guidelines and be fully operational. 2. Service Delivery Summary: 2.1. Scope of Work. The contractor shall supply all items required to properly install a fully functional turn-key BDA system in accordance with this SOW, manufacturer guidelines, applicable federal regulations, national professional codes and commercial practices/standards. Supplied items include, but are not limited to materials, personnel, vehicles, tools and equipment. In addition, the contractor shall provide a BDA technical solution, and warranty on install and system. 2.2 Installation Schedule. The performance period is 30 days of contract award. The contractor shall provide the Government an installation time period (i.e. 25 days from receipt of contract) and schedule time-line (i.e. Monday - Thursday 8:00 AM - 4:00 PM) with proposal. 2.3 Hours of Operation. 0700-2000, Monday - Friday, unless otherwise stated. 2.3 Warranty. Contractor shall provide the standard manufacturer warranty or a 1-year warranty (whichever is greater) on all parts, labor, and installation. 2.4 Technical Requirements. The antenna is to be mounted on a non-penetrating roof mount on the south side of the roof with the antenna pointed at the Cherry Creek site. The mast for the mount must be 2 3/8 inches OD and 60 inches in height. The antenna must be 10 db gain or higher with a front to back isolation rating of 16db or higher. The Transmission line must be 1/2 inch and must not be braided coax. The mast and antenna line must be grounded properly. The line is to be secured to the exterior of the building at manufacturers recommended intervals. The penetration must be weatherproof. Once inside, the transmission line must be routed and attached to lightning protection and grounded. The Amplifier is to be wall mounted at a serviceable level. The housing of the amplifier must be grounded. Any interior cabling after the amplifier must be plenum rated. The transmission line inside the building must be 1/2 inch and secured per manufacturer recommendations and local building codes. Where possible, cable must be at least four (4) inches away from parallel voice/data lines. The inside lines must be swept to verify continuity. 2.5 BDA Technical Requirments. The BDA installed will include the following, but not limited to, as a minimum: , Amplifier must be rated at +73db gain or higher , Frequency Range of 406-420Mhz , Pass 5Mhz BW 5-7Mhz , Contact closures for power failure alarms , UPS Backup power sufficient for 2 hours of operation 2.6 Building Overview. Brick structure consisting of the Base Exchange and Commissary 2.7 Physical Security. The contractor shall be responsible for safeguarding all Government property and controlled forms provided for contractor use. At the end of each work period, all Government facilities, equipment, and materials shall be secured. 3 Point of Contact (POC). 460 SCS/SCMR, 460 SCS/SCMR TSgt Daniel Clampitt, 1 NOTE: The above POCs do not have authority to obligate the Government or change the terms or conditions of the contract. 4.0 Site Clean-up. The contractor will be responsible for immediately cleaning up any spills, debris, etc., which may occur during construction. The contractor will be responsible for keeping construction areas in serviceable order. 5 .0 Pass and Identification. The Contractor shall ensure the pass and identification items (valid drivers license, current vehicle registration, and current insurance) required for the contract performance is obtained for employees and non-government owned vehicles with the Buckley Annex Security Office/Vistors Center. 5.1 Before arrival, the Contractor must mail, fax, or email a Visit Authorization Letter (VAL) to Jacqueline Carter, 460 CONS/LGCB, 720-847-6677, (fax) 720-847-6443, listing the employee's full name and company name on company letterhead. The VAL must provide the purpose, date, and a point-of-contact for the visit. 5.2 Upon receipt, the VAL will be given to the Buckley Annex Security Office/Visitors Center for issuance of a Visitor/Vehicle Pass. 6 Security Escorts. Will be provided by the Government, if required.
 
Place of Performance
Address: Buckley AFB (Aurora), CO
Zip Code: 80011
Country: UNITED STATES
 
Record
SN01139683-W 20060913/060911221041 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.