Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF SEPTEMBER 13, 2006 FBO #1752
SOLICITATION NOTICE

65 -- Test Measure Diagnostic Equipment for RTS Medical, Camp Parks, Dublin CA

Notice Date
9/11/2006
 
Notice Type
Solicitation Notice
 
NAICS
334510 — Electromedical and Electrotherapeutic Apparatus Manufacturing
 
Contracting Office
ARCC Fort McCoy Directorate of Contracting, Building 2103, 8th Avenue, Fort McCoy, WI 54656-5153
 
ZIP Code
54656-5153
 
Solicitation Number
W911SA-06-T-0093
 
Response Due
9/18/2006
 
Archive Date
11/17/2006
 
Small Business Set-Aside
N/A
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the Simplified Acquisition procedures in FAR 13 and the format in subpart 12.6, as supplemented with additional information included in this notice. This an nouncement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. W911SA-06-T-0093 is issued as a Request for Quotation (RFQ) and is due by 2:30 PM CST, 18 September 2006. This solicitation is unre stricted. NAICS code 334510 with a small business size standard of 500 employees. This RFQ and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-12. Request for quote on the following equipment or equal for CLINS 0001  0011: CLIN 0001. 3 EA @ ____________ = _____________Test Sequence Automated TQA-3: Mdl TQA-3 ZOLL NTP, ZOLL MEDICAL NTP ONLY, TQA-3 ZOLL, (TQA MODULE) 1000 ohm load, includes NTP inline connector . This is an accessory module that must be compatible with exis ting Defibrillator /Pacing analyzer, model Impulse 4000, Fluke brand or equivalent to test Zoll Heart Monitors/Pacers Model NTP 1000. CLIN 0002. 4 EA @ _____________= ____________ Test Sequence Automated TQA-9: MEDTRONIC PHYSIO-CONTROL, Mdl TQA-9, LIF EPAK SERIES QUIK PACE (TQA MODULE) MEDPPHYSCONT 100 ohm, 700 ohm, 1000 ohm, and 1500 ohm test load selections, includes snap connectors. This is an accessory module that must be compatible with existing Defibrillator /Pacing analyzer, model Impulse 4000, Fluke brand to test Lifepak Quik Pace series heart monitors/pacers. CLIN 0003. 3 EA @ ___________= ___________ Test Sequence Automated TQA-16: MEDTRONIC PHYSIO-CONTROL , Mdl TQA-16 LIFEPAK SERIES QUIK COMBO (TQA MODULE) MEDPHYSCONT, 100 ohm, 700 ohm, 1000 ohm and 1500 ohm load selections, includes gray inline connector. This is an accessory module that must be compatible with existing Defibrillator /Pacing analyzer, model Impulse 4000, Fluke brand to test Lifepak 8, 9P, and 10S heart monitors/pacers. CLIN 0004. 4 EA @ ___________= ___________ Test Sequence Automated TQA-17 ZOLL MEDICAL PD & M SERIES, Mdl TQA-17, (TQA MODULE), 100 ohm and 1000 ohm, ZOLLPD/M, load selections, includes inline connector. This is an accessory module that must be compatibl e with existing Defibrillator /Pacing analyzer model Impulse 4000, Fluke brand to test Zoll Heart Monitors/Pacers, Models PD and M. CLIN 0005. 7 EA @ ___________= ___________ ACCESSORY for the 199CM/PV350 PRESSURE VAC MODULE. This is an accessory module that must be compatible with existing Digital Oscilloscope, model 199CM/PV350, Fluke brand to measure pressures and vacuum for ven tilators and suction devices. CLIN 0006. 2 ea @ __________=___________ UW5-US 120V, ULTRASOUND WATTMETER , Mdl UW5-US120V, Compact, microprocessor-based, open tank configuration, ultrasound wattmeter, measures output of therapeutic ultrasound devices in the range of 0.1 to 30.0 watts. To include operators manual, battery eliminator, centering ring set, clamps and mount, calibration weight, weight adapter, and soft-sided nylon carrying case. This is the standard replacement for the UMR3-c,UMR3-d and UW 4 Ultrasound Wattmeters issued in Army Medical Sets, and special purpose test equipment calibrated and supported by The United States Army Medical Material Agency. CLIN 0007. 5 each @ ___________= __________ 217A PATIENT SIMULATOR, Mdl 217A-US-120V, includes 12-lead ECG and Arrhythmia simulation, 45 arrhythmia selections, 3 invasive BP channels including Swan-Ganz simulation, respiration simulation, temperature simulation, Interactive Intra-aortic balloon assist pump simulator (IABP), ECD performance testing, interactive defibrillation training, RS232 serial port, 2-line X 20-character display. To include operator/ service manual and soft-sided vinyl carrying case. This is the standard replacement for the Fluke Model 215M issued in Army Medi cal Sets, and special purpose test equipment calibrated and supported by the United States Army Medical Material Agency. CLIN 0008. 5 each @ __________= __________ CI-2B CABLE ASSEMBLY (Interface Cable), Mdl 3010-0386FG. Used for cardia c output function on 215A or 217A, connects between Patient Simulator and 21A controller. This is an accessory cable that must be compatible with the patient simulator 217A to calibrate and test Zoll electrocardiograms. CLIN 0009. 5 ea @ _________=_____________ UT-4 LOW PROFILE PLUG, Mdl UT-4, 1/4 inch phone plug, YSI 400 series compatible, 2 conductor. This is an accessory module that must be compatible with existing Digital Oscilloscopes, model 199CM/PV350, Fluke br and used to measure and calibrate patient monitors that measure and record temperatures. CLIN 0010. 5 ea @ ________= __________ ZOLL MEDICAL PD&M SERIES, Mdl 3010-0378, ELECTRODE ADAPTER, to include inline connector. This is an accessory module that m ust be compatible with existing Defibrillator /Pacing analyzer, model Impulse 4000, Fluke brand to test Zoll Heart Monitors/Pacers, Models PD and M issued in Army Medical Sets. CLIN 0011. 3 ea @ ________ = __________ SIGMAPACE 1000, Mdl SIGMAP1K-USA120V , INVASIVE PACEMAKER ANALYZER , 8-line X 21-character display, pulse output test, rate, current, volts, energy, pulse width, and AV internal, demand sensitivity and refractory tests, demand/async tests, line frequency noise rejection tests, battery load current test, dynamic and static DC leakage tests, long-term trending test, and interactive 5-lead ECG simulation. To include operators manual, transvenous pacer test leads, SigmaPace 9 VDC load test cable, serial interface cable, nylon carry case, unive rsal-input battery charger and USA 120 VAC power cord set. This is the specific pacemaker analyzer used to test and calibrate Model EC4542G, manufactured by Pace Medical Incorporated, and issued in Army Medical Sets. This special purpose test equipment i s calibrated and supported by The United States Medical Material Agency. This pacemaker analyzer is used to calibrate a critical care pacemaker which has leads surgically placed directly on the patient's heart. The full text of provisions and clauses in corporated herein may be accessed electronically at the following site: http://farsite.hill.af.mil/ and http://aca.saalt.army.mil/Library/Acq-Instructions.htm. The provisions at FAR 52.211-6 Brand Namre or Equal; FAR 52.212-1, Instructions to Offerors-Comm ercial; FAR 52.212-3 Alt I, Offeror Representations and Certifications-Commercial Items; DFARS 252.212-7000, Offeror Representations and Certifications--Commercial Items. Clause FAR 52.212-4, Contract Terms and Conditions-Commercial Items applies. FAR 52. 212-5, Contract Terms and Conditions Required To Implement Statutes or Executive Orders-Commercial Items applies with the following applicable clauses in paragraph (b): Convict Labor; 52.222-19, Child Labor-Cooperation with Authorities and Remedies; 52.222 -21, Prohibition of Segregated Facilities; 52.222-26, Equal Opportunity; 52.222-35, Equal Opportunity for Special Disabled Veterans , Veterans of the Vietnam Era, and Other Eligible Veterans; 52.222-36, Affirmative Action for Handicapped Workers; 52.222-37 , Employment Reports on Special Disabled Veterans, Veterans of the Vietnam Era, and Other Eligible Veterans; 52.225-13, Restriction on Certain Foreign Purchases; 52.232-33, Payment by Electronic Funds Transfer-Central Contractor Registration. DFARS Clause 252.212-7001 Contract Terms and Conditions Required to Implement Statutes or Executive Orders Applicable to Defense Acquisitions of Commercial Items applies with the following applicable clauses in paragraph (b): 252.225-7036, Buy American Act  North Ame rican Free Trade Agreement Implementation Act - Balance of Payments Program, Alt I; 252.232-7003, Electronic Submission of Payment Requests; and 252.247-7023, Transportation of Supplies by Sea , Alt III. Other provisions and clauses that apply include 252.225-7002, Qualifying Country Sources as Subcontractors; 252.225-7035 BAA-NAFTA Imp Act  Balance Pay Program Certificate; ACA AI clause 5152.233-9000 ACA Executive Level Agency Protest Program . 11. In accordance with FAR 39.106, the contractor shall ensure the offered product and all information technology (IT) contained therein shall be Year 2000 Compliant. PARTIES INTERESTED IN RESPONDING TO THIS RFQ may submit their quote in accordance with standard commercial practice (i.e. quote form, letterhead, etc.) and MUST INCLUDE THE FOLLOWING INFORMATION: Solicitation number, offerors complete mailing and remittance addresses, price per CLIN, discount terms, shipping cost, technical information dis playing features of proposed equal for comparison to suggested product, DUNS number, and Tax Identification Number. PROSPECTIVE CONTRACTORS SHALL ALSO complete electronic annual representations and certifications at http://orca.bpn.gov in conjunction with required registration in the Central Contractor Registration (CCR) database. In accordance with FAR 52.212-1(k), prospective awardee shall be registered and active in the CCR database prior to award. If the Offeror does not become registered in the CCR d atabase in the time prescribed by the Contracting Officer (NLT due date/time of solicitation), the Contracting Officer will proceed to award to the next otherwise successful registered Offeror. Offerors may obtain information on registration and annual co nfirmation requirements via the Internet at http://www.ccr.gov or by calling 1-888-227-2423 or 269-961-5757. A DUNS number is required for CCR registration. If your company does not have a DUNS#, obtain one by calling 800-333-0505. QUOTES MAY BE S UBMITTED by mail, Email or fax. If you have questions, contact Ginger Edgerton, Contract Specialist, ginger.edgerton@us.army.mil. Telephonic requests for information are discouraged. Quotes must be received at ACA Contracting, 2103 S 8th AVE, FORT MCCOY, WI, 54656-5153, no later than 18 Sep, 2:30 PM CST.
 
Place of Performance
Address: ARCC Fort McCoy Directorate of Contracting (for RTS Medical, CA) Building 2103, 8th Avenue, Fort McCoy WI
Zip Code: 54656-5153
Country: US
 
Record
SN01139802-W 20060913/060911221235 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.