Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF SEPTEMBER 17, 2006 FBO #1756
SOLICITATION NOTICE

59 -- TRANSFORMERS

Notice Date
9/15/2006
 
Notice Type
Solicitation Notice
 
NAICS
335311 — Power, Distribution, and Specialty Transformer Manufacturing
 
Contracting Office
US Army Humphreys Engineer Center Support Activity, ATTN: CEHEC-CT, 7701 Telegraph Road, Alexandria, VA 22315-3860
 
ZIP Code
22315-3860
 
Solicitation Number
W912HQ06T0032
 
Response Due
9/22/2006
 
Archive Date
11/21/2006
 
Small Business Set-Aside
Total Small Business
 
Description
Action Code: Combined Synopsis/ Solicitation Notice Class Code: 59 NAICS Code: 335311 Subject: Transformers Solicitation Number: W912HQ-06-T-0032 Set-Aside Code N/A Response Date: 09/22/2006 Place of Performance: U S Army Humphreys Engineer Center Support Activity ATTN: CEHEC-CT, 7701 Telegraph Road Alexandria, VA 22315-3860 Description: This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in subpart FAR 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitatio n; Quotes are being requested and a written solicitation will not be issued. Quotes are due back 5 days from the RFQ date. Hard copies of the solicitation will not be available. Interested parties are responsible for monitoring the FedBizOpps website at: w ww.fedbizopps.gov for current status of solicitations and amendments. All quotes received from responsible sources will be considered by this office. All offerors will be ineligible for award unless they have registered in the DoD Contracting Registration database at http://www.ccr.gov. All offerors will also include a schematic for user to view transformer dimensions. The contract type will be a Firm Fixed Price and the RFQ due date is 22 Sep 2006. Quotes will not be accepted after due date. This procureme nt is a Small Business Set-Aside The North American Industry Classification System (NAICS) code is 335311. The solicitation number is W912HQ-06-T-0032. The following FAR provisions apply: FAR 52.212-1, 52.212-3, 52.212-4, 52.212-5, 52.252-2. This request is for two (2) different types of transformers with a request for four of each: The first is for four (4) each Step-Up transformers, substation type, oil filled, size 2000KVA, three phase, 65 degree C rise, 60 hertz voltage rating, primary (output) 120/277 /480 vac, secondary voltage (output) 4,160 vac. General Characteristics: Welded on cover, Bolted on inspection plate, tamper proof high voltage terminal cabinet with a minimum of three (3) latching points, padlockable door and removable tamper proof low vo ltage terminal chamber cabinet with a minimum of three (3) latching points, padlockable door and removable bottom for conduit or cable entrance, lifting eyes with 1 ? inch hole, liquid level gauge, dial type thermometer, two (2) each stainless steel ground s pads, transformer filled with non P.C.B. mineral oil, bottom of transformer will be undercoated to prevent corrosion, automatic pressure relief valve, height will not exceed 85 inches to the top of the transformer, will not exceed 80 inches. The second is for four (4) each Substation type, oil filled, size 2500KVA, three phase, 65 degree C rise, 60 hertz voltage rating: 2400Delta X 4160Y/2400 X 720 Delta X 1270Y/7200-480Y/277 with taps in 8320-7970-7620-6928 Delta/14400Y-13800Y-13200Y-12470Y-12000Y volt s. General Characteristics: Welded on cover, bolted on inspection plate, tamper proof high voltage terminal chamber cabinet with a minimum of three (3) latching points, padlockable door and removable bottom for conduit or cable entrance, tamper proof low voltage terminal chamber cabinet with a minimum of three (3)latching points, padlockable door and removable bottom for conduit or cable entrance, lifting eyes with a 11/4 inch hole, liquid level gauge, dial type thermometer, externally operated no load tap changer lockable in any position, 2 each stainless steel ground pads, transformer filled with non P.C.B. mineral oil, externally no-load Delta-Wye switch, externally operated no-load dual voltage selector switch, bottom of transformer will be undercoated to prevent corrosion, automatic pressure relief valve, height will not exceed 85 inches to the top of the transformer, width will not exceed 80 inches. All interested parties should submit their quote and schematic to attention of Barbara Lawrence, fax 703 -428-8181 or e-mail: Barbara.a.lawrence@hqda.usace. army.mil.
 
Place of Performance
Address: US Army Humphreys Engineer Center Support Activity ATTN: CEHEC-CT, 7701 Telegraph Road Alexandria VA
Zip Code: 22315-3860
Country: US
 
Record
SN01145361-W 20060917/060915221535 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.