MODIFICATION
99 -- Diesel Generator
- Notice Date
- 9/18/2006
- Notice Type
- Modification
- NAICS
- 335312
— Motor and Generator Manufacturing
- Contracting Office
- ACA, Fort Carson, Directorate of Contracting, 1676 Evans Street, Building 1220, 3rd Floor, Fort Carson, CO 80913-5198
- ZIP Code
- 80913-5198
- Solicitation Number
- W911RZ-06-T-0061
- Response Due
- 9/20/2006
- Archive Date
- 11/19/2006
- Point of Contact
- LaTischa Castro, 719-526-4324
- E-Mail Address
-
ACA, Fort Carson
(latischa.castro@us.army.mil)
- Small Business Set-Aside
- Total Small Business
- Description
- The purpose of this amendment is to provide answers to questions received. Question: It is our current understanding that you are requesting only the GenSet with a base tank and on-site testing and training. You do not require an ATS, disconnects or installation services, correct? Answer: The requirement is for a 500 kW packaged generator with outdoor enclosure and base tank. All ATS, installation, and connection services will be performed by a separate contract. Question: Is the due date going to change? Answer: The deadline for proposal submission has not changed. Question: The Statement contains square boxes. Could you help me to clarify the text? What do the squares mean? Answer: The square boxes in the combined synopsis/solicitation are a formatting error. The square boxes should be hyphens. Question: Should the generator be mounted on a trailer for transportation? Answer: The generator will be placed outside on a concrete slab. A trailer is not required. Question: Is the generator going to be placed in a room or outside? Answer: The generator will be placed outside. The outdoor enclosure shall match the exterior brick facade. Question: The RFG calls for: 500kW 120/208V 1200A circuit breaker The following shows the amperages allowed at different voltages based on a 500kW output. 208V = 1734A 240V = 1503A 480V = 751A This shows that we need to go with 480V and also we need to go with an 800A circuit breaker (based off a circuit breaker overload of 115%). Is this correct? Answer: The 1200 amp rating is incorrect. The correct rating should be 2000 amp. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (18-SEP-2006); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link to FedBizOpps document.
(http://www.fbo.gov/spg/USA/DABJ/DABJ13/W911RZ-06-T-0061/listing.html)
- Place of Performance
- Address: ACA, Fort Carson Directorate of Contracting, 1676 Evans Street, Building 1220, 3rd Floor Fort Carson CO
- Zip Code: 80913-5198
- Country: US
- Zip Code: 80913-5198
- Record
- SN01147774-F 20060920/060918224049 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |