MODIFICATION

99 -- Fiberglass Fis Culture Tanks

Notice Date
9/20/2006
 
Notice Type
Modification
 
NAICS
326199 — All Other Plastics Product Manufacturing
 
Contracting Office
Department of Agriculture, Agricultural Research Service, North Atlantic Area Office, 600 East Mermaid Lane, Wyndmoor, PA, 19038
 
ZIP Code
19038
 
Solicitation Number
AG-3615-S-06-0007
 
Response Due
9/25/2006
 
Point of Contact
Eileen LeGates, Procurement Assistance Officer, Phone 215-233-6551, Fax 215-233-6558,
 
E-Mail Address
eileen.legates@ars.usda.gov
 
Description
LINE ITEM 01: Fiberglass fish culture tank, square shaped with 15 ft side walls or circular shaped with 15 ft diameter walls, 42 inches overall height to hold operating water depth of 36 inches, equally space screen guides 2 inches by 2 inches placed in all sides walls (reference drawing), top of tank wall should have a minimum 3 inch wide flange plate, 24 inch square center drain sump slopes to a 3 inch diameter center drain outlet (reference drawing of center drain), 10-24 inch diameter aluminum, stainless steel, or PVC center drain plate with anchoring, 6 inch diameter PVC coupling side outlet fiberglassed into bottom of outlet box on side of tank, side box approx. 12 inches high x approx. 18 inches wide x approx. 16 inches deep, tank with flat bottom to be placed on a concrete floor, tank flooded capacity approx. 5890 gallons for square shaped or 3965 gallons for circular shaped with operating capacity of approx. 5050 gallons for square shaped or 4626 gallons for circular shaped, tank supplied with predrilled side flanges, stainless steel bolts and nuts, fiberglass resin, fiberglass matt, and gel coat. QUANTITY 3 EACH LINE ITEM 02: Fiberglass fish culture tank, square shaped with 16 ft side walls or circular shaped with 16 ft diameter walls, 42 inches overall height to hold operating water depth of 36 inches, top to tank wall should have a minimum 3 inch wide flange plate, 24 inch square center drain sump slopes to a 3 inch diameter center drain outlet (reference drawing of center drain), 10-24 inch diameter aluminum, stainless steel, or PVC center drain plate with anchoring, 6 inch diameter PVC coupling side outlet fiberglassed into bottom of outlet box on side of tank, side box approx. 12 inches high x approx. 18 inches wide x approx. 16 inches deep, tank with flat bottom to be placed on a concrete floor, tank flooded capacity approx. 6702 gallons for square shaped or 5264 gallons for circular shaped with operating capacity of approx. 5745 gallons for square shaped or 4512 gallons for circular shaped, tank supplied with predrilled side flanges, stainless steel bolts and nuts, fiberglass resin, fiberglass matt, and gel coat. QUANTITY 5 EACH OPTION I LINE ITEM 03: Fiberglass fish culture tank, circular shaped 8 ft diameter walls, 48 - 50 (maximum) inches overall height to hold operating water depth of 36 inches, top of tank wall should have a minimum 3 inch wide flange plate, 18 inch square center drain sump slopes to a 3 inch diameter center drain outlet (reference drawing of center drain), 10-24 inch diameter aluminum, stainless steel, or PVC center drain plate with anchoring, tank with maximum 6-8 inch bottom skirt to accommodate sump and drain pipe, tank flooded capacity approx. 1316 gallons with operating capacity of approx. 1128 gallons, tank supplied with predrilled side flanges (if tanks are manufactured in sections), stainless steel bolts and nuts, fiberglass resin, fiberglass matt, and gel coat. QUANTITY 4 EACH ALL THIS FOR A TOTAL AMOUNT OF $ Line Items 01 and 02, tank side outlet box to be fiberglassed to panels by manufacturer before delivery. ALL TANKS - Tank exterior color to be gray, dark green, or white and interior gel coat color to be medium blue or approved colors. Also see Section Attached Drawings Add to Section 52.212-2 EVALUATION ? COMMERCIAL ITEMS (JAN 1999) (b) Options. The Government will evaluate offers for award purposes by adding the total price for all options to the total price of the basic requirement. The Government may determine that an offer is unacceptable if the option prices are significantly unbalanced. Evaluation of options shall not obligate the government to exercise the option(s). Please email Eileen.LeGates@ars.usda.gov for copy of drawing. Responses are due on SEPTEMBER 25, 2006 by 4:00 p.m. EDT, to the USDA, Agricultural Research Service, NAA, 600 East Mermaid Lane, Wyndmoor PA 19038. NOTE: THIS NOTICE MAY HAVE POSTED ON FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (20-SEP-2006). IT ACTUALLY APPEARED OR REAPPEARED ON THE FEDBIZOPPS SYSTEM ON 16-OCT-2006, BUT REAPPEARED IN THE FTP FEED FOR THIS POSTING DATE. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
 
Web Link
Link to FedBizOpps document.
(http://www.fbo.gov/spg/USDA/ARS/NAAO/AG-3615-S-06-0007/listing.html)
 
Place of Performance
Address: 11861 Leetown Road, Kearneysville, WV
Zip Code: 25430-5500
Country: UNITED STATES
 
Record
SN01166375-F 20061018/061016222123 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.