MODIFICATION
Y -- 16 January 2007 W917PM-07-R-0003 Synopsis Coordinates Corrected
- Notice Date
- 1/16/2007
- Notice Type
- Modification
- NAICS
- 236220
— Commercial and Institutional Building Construction
- Contracting Office
- U.S. Army Corps of Engineers, Afghanistan, Afghanistan Engineer District, Kabul AFB, APO, AE 09356
- ZIP Code
- 09356
- Solicitation Number
- W917PM-07-R-0003
- Response Due
- 2/28/2007
- Archive Date
- 4/29/2007
- Small Business Set-Aside
- N/A
- Description
- Design and Construct ANA Garrison in Jalalabad The U.S. Army Corps of Engineers, Afghanistan District intends to issue a Request for Proposal (RFP) to award a Firm Fixed Price contract for the design/construction of an ANA Garrison in Jalalabad, Afgh anistan. Coordinates: N34.526546 E70.349318 (1328m) N34.517399 E70.360050 (1343m) The contractor shall perform work to consist of mine clearing, topographic survey, installation master planning, site demolition (as required) grading, design and constructio n of new buildings, construction of prime power plant and electrical distribution system, construction of a waste water treatment aerated stabilization pond and sanitary sewer system, solid waste transfer points, development of a raw water source ( i.e. gr ound source water wells), installation of water well pumps, potable water booster pumps and associated controls, installation water distribution system, construction of water storage tanks, design and construction of data, voice and emergency communication system including centralized communications building and underground copper cable installed in duct banks system, provide range master planning, design and construction of multi-purpose training ranges, design and construct an asphalt concrete road networ k on new base, POV and military parking areas, construction of perimeter fencing IAW AT/FP measures. Installation landscaping shall incorporate the storm water runoff plan and allow for proper site drainage, grading throughout the compound with drainage st ructures. The site master plan shall include planned locations for future additional facilities that will be designed and built by others. The list of future facilities to be master planned (in this contract) but built by others include: Community Center ( 900m2); Sports Field with reviewing stand and soccer field (standard 400m track); DPW Shop Building (800m2); 1 each Battalion Arms Storage Building (350m2 each); Warehouse (1520m2); Infantry Battalion Motor pools (2000m2); and a Mosque (785m2). The contrac tor shall provide utility connections designed for the future connection of these facilities. Attached to Section 01015 is a site plan from Mazar-e-Sharif, Afghanistan that shows the general relationships between facilities and is to be used only as a n ex ample in developing any master planning (All Master Planning shall conform to this REP). The contractor shall perform a geotechnical investigation as defined in Section 01015. An approved site grading and Drainage Plan shall be prepared prior to constructi on. All utilities shall be complete and operational prior to the occupancy. The award for this procurement will be made in accordance with the applicable Federal Acquisition Regulations. The applicable NAICS code is 236220. The magnitude of this requiremen t is between $25,000,000.00 and $100,000,000.00. The proposed contract will be awarded using best value evaluation methods. Solicitation Number W917PM-07-R-0003 will be available on or about January 31, 2007. Point of contact for this procurement is Merlin D. Simonson, Contract Specialist, US Army Corps of Engineers, Afghanistan District, CEAED-CT, Kabul, Afghanistan, APO AE 09356 via email Merlin.D.Simonson@tac01.usace.army.mil. The media selected for the issuance of solicitation and amendments shall solel y be at the discretion of the Government; accordingly, the media utilized for this project is the Internet. No paper copies will be made available. Electronic Bids Will Not Be Accepted. Interested parties may download and print the solicitation at no charg e at http://www.aed.usace.army.mil/solicitations.html or ftp://ftp.usace.army.mil/pub/aed/. Requirements: DFARS 252.204-7004 Required Central Contract registration applies to this procurement. Prospective contractors must be registered in the Department of Defense CCR database prior to award. Information on CCR registration and annual confirmation requirements may be obtained by calling 1-888-227-2423 or via the internet at http://www.ccr.gov.
- Place of Performance
- Address: U.S. Army Corps of Engineers, Afghanistan Afghanistan Engineer District, Kabul AFB APO AE
- Zip Code: 09356
- Country: AF
- Zip Code: 09356
- Record
- SN01212195-W 20070118/070116220901 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |