MODIFICATION
65 -- Diagnostic Imaging System
- Notice Date
- 2/9/2007
- Notice Type
- Modification
- NAICS
- 423450
— Medical, Dental, and Hospital Equipment and Supplies Merchant Wholesalers
- Contracting Office
- Department of the Air Force, Air Mobility Command, 319 CONS, 575 Tuskegee Airmen Blvd, Building 418, Grand Forks AFB, ND, 58205, UNITED STATES
- ZIP Code
- 58205
- Solicitation Number
- FM465970167000
- Response Due
- 2/15/2007
- Archive Date
- 3/2/2007
- Point of Contact
- Michael Haack, Contract Specialist, Phone 701-747-5294, Fax 701-747-4215,
- E-Mail Address
-
michael.haack@grandforks.af.mil
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; quotes are being requested and a written solicitation will not be issued. This solicitation, FM465970167000, is being issued as a Request for Quotation (RFQ). This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular (FAC) 2005-02. The NAICS code is 423450. The following commercial items are requested in this solicitation: Line Item 0001: Request Quantity (2) DIAGNOSTIC IMAGING SYSTEMS; System must be suitable for producing radiographic images of patient skeletal and soft-tissue anatomy in recumbent, seated and erect positions. It is to be utilized to perform orthopedic diagnostics, trauma, general, and thoracic diagnostic studies. Table - Able to support a patient weighing up to 450 lbs - Composed of radiolucent material - Floating top that can be moved either transversely or longitudinally - Entire table assembly that can be raised up to 35 inches or as low as 12 inches from the floor - Electromagnetic locks to hold the table in place once positioned - Accessible from all four sides - A "Bucky Tray" for producing photo-timed exposures centered under the table A focused grid for 45 inch Source to Image Distance (SID) exposures A ratio of 12:1 with 40 lines per cm Minimum three field ion chambers Able to accommodate film cassette sizes from 8 x 10 inches to 14 x 17 inches Can be moved longitudinally within the table - Table side controls to regulate height, release/lock the table top - Emergency power disconnect switch Tube Assembly Support - Ceiling mounted, adjustable in three spatial axes, with tube assembly and collimator for vertical, horizontal, and lateral acquisitions - Travel range: 140 inches or more longitudinally, 127 or more inches transversely, 60 inches vertically - Manually adjustable tube assembly and support - Can be swiveled manually around the vertical axis of the tube support - Pivot between +154 degrees and -182 degrees around the vertical axis of the tube assembly support Lock-in positions at 0 degrees and ?90 degrees, ?120 degrees around the horizontal axis, lock-in positions at 0 degrees and ?90 degrees Collimator - Full field localizer for optical display of collimated exposure field - Collimated field size can be manually adjusted - Collimator can be rotated minimum ?50 degree around the beam center - Filtration system for reduction of radiation during soft tissue exposures - Controls and displays at the tube assembly support: longitudinal, transverse, vertical, angulation, detent X-Ray Tube Assembly - Dual focus rotating anode - High heat storage capacity - High load capacity - Integrated thermal monitoring device - Protective housing and X-ray tube for 150 kV nominal voltage - Nominal power: 40 kW; small focus 80 kW; large focus Anode speed =8,000 revolutions/min Anode angle 12 degree Overall filtration 2.5 mm AL Control Console - Touch-screen design - Able to select manual or automatic exposure technique - Exposure dose display for photo timed exposures - Exposures can be selected based on body region Generator Pre-transformer - Required for voltages of 440 V and 480 V Vertical Bucky Stand - Floor/wall mounted grid acquisition system - Height adjustable between 14 inches and 75 inches cassette center above floor - Left or right hand operation - Able to accommodate cassette sizes ranging between 8 x 10 inches and 14 x 17 inches - Removable grid for pediatric imaging - Overhead handle to facilitate lateral thoracic position of patient - Transparent lead (Pb) grid 13:1 ratio with 70 lines/cm at 60 inch SID High Frequency X-ray Generator - Multi-processor system capable of supporting all electrical requirements of x-ray system Deinstallation/Room Preparation - Vendor will be responsible for removal of existing unit and all associated equipment or provide credit for turn in of existing equipment - Vendor will perform any necessary pre-installation room preparation Training - Include Biomedical Equipment Repair Technician training - In-service training for radiologic technologists Statement of Work - From date of award vendor will have 90 days to install both units - Final payment is contingent upon Health Physicist acceptance testing To include 2 sets of Operator and Service Manuals To include installation/set up, training To include delivery/transportation costs Contractor is required to remove any Legacy equipment supports no longer necessary for installation of new equipment. Any electrical modification or additional requirement will require Civil Engingeering approval and sufficient lead time to accomplish. Installation contractor will have to repair any damage to walls, flooring, etc which may occur during install. Area will have been completely renovated prior to install. Facility Manager Michael Curtis. FOB: Destination for delivery to 319 MEDICAL GROUP; TSGT TRACY WYNNE 1599 J ST GRAND FORKS AFB ND 58205 TEL: 701-747-5594. The following provisions and clauses apply to this acquisition. The provision at FAR 52.212-1, Instructions to Offeror?s--Commercial Items. Quotes will be evaluated and awarded to the offeror with the lowest price technically acceptable. The provision at FAR 52.212-3, Offeror Representations and Certifications -- Commercial Items, and the offeror must include a completed copy of this provision with their proposal. The clause at FAR 52.212-4, Contract Terms and Conditions-Commercial Items; FAR 52.212-5, Contract Terms and Conditions Required To Implement Statutes or Executive Orders--Commercial Items. Specifically, the following clauses cited are applicable to this solicitation: FAR 52.222-26, Equal Opportunity; FAR 52.222-35, Affirmative Action for Disabled Veterans and Veterans of the Vietnam Era; FAR 52.222-36, Affirmative Action for Handicapped Workers; FAR 52.222-37, Employment Reports on Disabled Veterans and Veterans of the Vietnam Era. The clause at FAR 52.224-1, Privacy Act Notification and FAR 52.224-2, Privacy Act; FAR 52.232-33, Payment by Electronic Funds-Central Contractor Registration. The clause at DFARS 252.204-7004, Required Central Contractor Registration; DFARS 252.212-7001, Contract Terms and Conditions Required to Implement Statues or Executive Orders; DFARS 252.225- 7001, Buy American Act and Balance of Payment Program. The Government reserves the right to award on a multiple award or an all or none basis. All firms must be registered in the Central Contractor Registration database @ www.ccr.gov and shall be considered for award. All quotes must be sent to A1C Michael Haack at: Fax 701-747-4215; e-mail michael.haack@grandforks.af.mil; or mail directly to 319 Contracting Squadron, 575 Tuskegee Airmen BLVD, Grand Forks AFB, ND, 58205-6436. Quotes are required to be received no later than 1600HRS CST on 17 FEB 2007. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (09-FEB-2007); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link to FedBizOpps document.
(http://www.fbo.gov/spg/USAF/AMC/319CONS/FM465970167000/listing.html)
- Place of Performance
- Address: 319 Medical Group; TSgt Tracy Wynne 1599 J St. Grand Forks AFB, ND 58205 Tel: 701-747-5594
- Zip Code: 58205
- Country: UNITED STATES
- Zip Code: 58205