Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MARCH 16, 2007 FBO #1936
SOLICITATION NOTICE

66 -- GAS CROMATOGRAPH

Notice Date
3/14/2007
 
Notice Type
Solicitation Notice
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
Department of the Air Force, Pacific Air Forces, 374 CONS - Yokota, Unit 5228, Yokota AB, APO Japan, ., 96328-5228, UNITED STATES
 
ZIP Code
00000
 
Solicitation Number
FA520907T0092
 
Response Due
3/21/2007
 
Archive Date
4/5/2007
 
Description
NOTE: THIS SOLICITATION IS INTENDED ONLY FOR JAPANESE LOCAL VENDOR. The contractor shall provide all personnel, equipment, tools, transportation, supervision, set-up services, initial training, and all other items and services necessary to provide and install a Gas Chromatograph (GC) system to U.S. Army Garrison Japan, Camp Zama. The GC is required for measurements of PCB, Alkyl Mercury and Organic Phosphorus Compounds in aqueous solution. Typical use of the GC at the Environmental Division Laboratory is the quantitative analyses of environmental samples. The GC system must be capable of analysis using GC methods, which are specified under the Environmental Quality Standards for Water Pollution. PCB: Japan Ministry of the Attached Table 3, Japan Environment Agency?s Guidance No. 59 and JIS K 0093, Gas Chromatograph Method. Alkyl Mercury: Japan Ministry of the Attached Table 2, Japan Environment Agency?s Guidance No. 59 Gas Chromatograph Method. Organic Phosphorus Compounds: Japan Ministry of the Attached Table 1, Japan Environment Agency?s Guidance No. 64 Gas Chromatograph Method. Injection Unit: Select form 2 types of ECD (Electron Capture Detector) and FPD (Flame Photometric Detector) injection units. Column Oven: The column oven must have an operating range of 35oC to 400oC or wider. The oven must minimally be; capable of programmable multiple heating ramp rates; able to increase the temperature from 50oC to 400oC and cool-down from 400oC to 50o in less than 10 minutes; temperature stability within 0.1oC of actual temperature. Detector: Select form 2 types of ECD (Electron Capture Detector, Certificated ECD with indication.) and FPD (Flame Photometric Detector) detector units. Packed column analysis is support. Carrier gas flow control system: Auto flow electronic control system. See attached ?SPECIFICATION AND REQUIREMENTS? for more detailes. OR EQUAL MANUFACTURE If you intend on quoting equal items, quotes will not be considered without the manufacture?s part number and specifications or detailed catalog excerpt. If you are unable to quote.
 
Place of Performance
Address: UNIT 5228, BLDG 620,, YOKOTA AB, FUSSA-SHI, TOKYO,
Zip Code: 197-0001
Country: JAPAN
 
Record
SN01250906-W 20070316/070314221145 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.