Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MARCH 23, 2007 FBO #1943
SOLICITATION NOTICE

23 -- TRAILER FIRE SAFETY HOUSE AND MOBILE COMMAND CENTER

Notice Date
3/21/2007
 
Notice Type
Solicitation Notice
 
Contracting Office
M67001 Marine Corps Base Camp Lejeune, NC
 
ZIP Code
00000
 
Solicitation Number
M6700107Q0050
 
Response Due
4/6/2007
 
Archive Date
5/6/2007
 
Description
This is a combined Synopsis/Solicitation for commercial items prepared in accordance with the format in subpart 12.6 as supplemented with additional information included in this notice. This announcement constitutes the solicitation; quotes are being requested and a written solicitation will not be issued. This is a request for quotation (RFQ) and the solicitation number is M6700107Q0050. Document number is M9304007SS00005. The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 05-12. The North American Industrial Classification System (NAICS) for this requirement is 336214 and the small business size standard is 500 employees. Item #0001: SURREY Fire Safety House and Mobile Command Center. Model number: 36BLTD1 Fiberglass Exterior. With the following criteria: Approximately 36?6? long, 8 feet wide and 10?10? high. Interior height 90 inches, GVW 7,040#, GVWR 10,400#. Hitch Wt 880#, Axle Wt 6,160#. Outside shall be fiberglass ? gel coat with high gloss. Inside shall contain the following features: Fiberglass Interior Walls, Color Camera System, Carbon Monoxide training aid, Bedroom Smoke Detector (Functional), Hearing Impaired Smoke Alarm (Functional), Exit Sign (Functional), PA System throughout, Pull Station with Horn and Strobe (Functional), 110 Volt Refrigerator (Functional), Roof Strobe (Functional), Faming Pot on Stove Training Aid, Wireless Flaming Trash Can Training Aid, Severe Weather Training Aid Package, Bleacher Seating, Wireless Smoke Machine Training Aid, Stove Top Fire Suppression Training Aid, TV / VCR / DVD for Outside Viewing/Training, TV / VCR / DVD for Interior Viewing/Trainin g. Other Features contained within the Fire Safety Trailer: Portable Sprinkler Module (Functional), Skid Wheels on Rear of Trailer, Roof should be Insulated, Have Air Conditioning throughout, Minimum of 4 Electric Leveling Jacks, Internal Generator to Support all interior and exterior options, Fuel Tank for Generator shall be mounted on Safety Trailer, External Flood Lights. Include Outside Lettering: Marine Corps Fire Service Emblem, and Safety Decals to include the following on both sides and the rear - Camp Lejeune Fire & Emergency Services Division Camp Lejeune, North Carolina- Quantity: 0001 ea. Quotes other than FOB Destination TMO Camp Lejeune, North Carolina 28542 will be rejected. The following Federal Acquisition Regulation (FAR) and Defense Federal Acquisition Regulation Supplement (DFARS) provisions and clauses apply to this acquisition: FAR 52.212-1 Instructions to Offers. Commercial Items; FAR 52.212-3 Offeror Representations and Certifications. Commercial Items; FAR 52.212-4 Contract Terms and Conditions. Commercial Items; FAR 52.212-5 Contract Terms and Conditions Required to Implement Statutes of Executive Orders. Commercial Items, DFARS 252.212-7001 Contract Terms and Conditions Required to Implement Statutes or Executive Orders Applicable to Defense Acquisitions of Commercial Items, DFARS 252.225-7000 Buy American Act-Balance of Payments Program Certificate, and DFARS 252.212-7000 Offeror Representations and Certifications-Commercial Items. OFFEROR SHALL PROVIDE COMPLETED COPIES OF FAR 52.212-3 AND DFARS 252.225-7000 WITH THEIR QU OTE. The Offeror is required to provide their Contractor?s DUNS Number and Commercial and Government Entity (CAGE) code with their quote. The CAGE code entered must be for that name and address provided by the Contractor. DFAR 252.204-7004 (mar 1998) Offerors are required to be registered in the Central Contractor Registration database (CCR), and Wide Area Work Flow database, FAR 252.232-7003 (DEC 2004). For WAWF-RA at http://wawf.eb.mil. WAWF Assistance 910-451-2142. For more information about registering, contact CCR regional Assistance Center 888-227-2423 or visit their website (www.ccr.dlsc.dla.mil). Offerors must be registered prior to receiving an award for this acquisition or for any future awards. Offerors are required to be registered in Wide Area Work Flow DFARS. 252.232-7003. Offerors responding to this announcement shall submit their quotations in accordance with FAR 52.212-1. The closing date for this solicitation is 06 APR 07 by 4:00 P.M, EST. Submit quotes to jose.e.rodriguez1@usmc.mil or fax to (910) 451-2193.
 
Web Link
NECO
(http://NECO.NAVY.MIL)
 
Record
SN01256289-W 20070323/070321221951 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.