Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF APRIL 06, 2007 FBO #1957
SOURCES SOUGHT

Y -- LITTORAL WARFARE FACILITY, PANAMA CITY, FL

Notice Date
4/4/2007
 
Notice Type
Sources Sought
 
NAICS
236220 — Commercial and Institutional Building Construction
 
Contracting Office
Department of the Navy, Naval Facilities Engineering Command, NAVFAC Southeast, South, 2155 Eagle Drive, North Charleston, SC, 29406, UNITED STATES
 
ZIP Code
00000
 
Solicitation Number
Reference-Number-N69450-IPTGC-RE1
 
Response Due
4/17/2007
 
Description
THIS IS A SOURCES SOUGHT NOTICE ONLY. THIS IS NOT A REQUEST FOR PROPOSAL. THERE WILL NOT BE A SOLICITATION, SPECIFICATION, OR DRAWINGS AVAILABLE. The Reference Number for this announcement is N69450-IPTGC-RE1. The Government will use responses to this Sources Sought Market Survey to make an appropriate acquisition decision. CONTRACT TYPES www.wbdg.org-The Government anticipates awarding a contract for the Littoral Warfare Facility, Panama City, FL within the next 12 months. This project will require complete design and construction services. EVALUATION CRITERIA ? Provide information on your firm?s experience, past performance and financial strength to handle this contract. Also provide information on your staffing plan and work approach that will give the Government a high level of confidence that the work will be completed within project completion time and within budget constraints and at the same time meet the Government?s quality expectations. The estimated cost for this design build project is between $11,000,000 and $12,000,000. Indicate your firms capability in the type work listed below: PROJECT DESCRIPTION: Design Build contract to construct a two story building with pile foundation and grade beams, structural steel and?or concrete frame, metal and?or builtup roofing, and masonry?stucco exterior walls. The building includes an automatic fire sprinkler system, technical operating manuals, intrusion alarm system, heating, ventilation and air conditioning, and an elevator. Special features include exterior rollup doors, high bays with overhead crane, loading dock, forklift rated floors, local area network wiring, 400 cycle power, 220V power connections, raised flooring for the computer labs an emergency generator, paving and site improvements. The building will be a secure facility with limited access. The contractor will be required to demolish buildings 76, 79, 376, 404, 409, 412, 451, and 491, approximately 3,136 m2 (33,763 SF) of existing facilities. The contractor will be required to provide temporary facilities, (trailers) to accommodate the relocated personnel from the demolished buildings of this project. The project will conform to Anti Terrorism Force Protection standards and incorporated sustainable features. The construction duration will be less than or equal to 555 calendar days from date of contract award. EVALUATION CRITERIA - Provide information on your firm?s experience, past performance and financial strength to handle this contract including any Joint venture or mentor-prot?g? relationships. Also provide information on your logistics plan, staffing plan, and work approach that will give the Government a high level of confidence that the work will be completed within project time and budget constraints and will meet the Government?s quality expectations. A. Provide information concerning your Experience on similar projects and how well you Performed on those projects: ? Up to three similar projects with one being completed within the last 3-years- to include a description of the project, construction cost, completion date, information demonstrating satisfactory performance, and contact information for references. For design/build projects, include the name of the A/E firm used and your relationship with that A/E; i.e. how many projects you have collaborated on, etc. ? Describe your firms overall design/build experience. B. Provide the following Financial information: ? Letter from your surety indicating your bonding capacity for a single project and total aggregate bonding capacity. ? Letter from your bank specifying the amount of your line of credit and amount available under this line. ? Provide the first page of your Central Contractor Registration (CCR) profile from www.ccr.gov. ? Identify business category: large or small (if small indicate which if any of the following Federal government sub-categories apply to your firm; Veteran Owned Small Business, Service Disabled Veteran-Owned Small Business, HUBZone Small Business, Small Disadvantaged Small Business, 8(a) certified Small Business or Woman Owned Small Business). C. Provide narrative of a Logistics Plan that addresses the following: ? Identify major materials, including likely sources and storage locations for equipment that will require long lead time and large volumes. ? Identify the strategy for berthing and meal provisions of the entire workforce. D. Provide a Staffing Plan that addresses the following: ? Organizational Chart that identifies the key personnel and individuals on the project team that show clear lines of authority, responsibility, and communication between corporate staff, key on-site staff, and subcontractor interface o Provide resumes of key personnel. o Identify the A/E firms that you anticipate using on design/build projects. ? Identify work that will be typically self performed as well as necessary subcontractors ? Indicate relationship that exists with the subcontractors or the means in which others will be established ? Provide evidence that you can provide an appropriate workforce (skilled & unskilled) in this market. ? List A/E firms that small businesses have worked w/in the past. Provide narrative of a Work Approach that addresses the following: ? Familiarity with the difficulties, uncertainties and risks associated with the work and identify risk mitigation strategies (i.e., long lead items, etc.) ? Management techniques that have been used for early detection/resolution of issues concerning differing site conditions, customer requested changes, etc. ? Provide techniques that may be used to minimize time growth. THE CLOSING DATE FOR SUBMITTING THE ABOVE CRITERIA IS TUESDAY, 17 APRIL 2007 AT 2:00pmEDT. The number of submittals required is one original and two copies. Electronic submissions will not be accepted. The address for submitting your package in regards to this Sources Sought Market Survey is: NAVAL FACILITIES ENGINEERING COMMAND, SOUTHEAST, ATTN: MS RHONDA EARNEY, CODE IPTGC/REE, P. O. BOX 190010 N. CHARLESTON, S.C. 29419-9010. FOR FEDERAL EXPRESS PURPOSES 2155 EAGLE DRIVE, N. CHARLESTON, S. C. 29406.
 
Place of Performance
Address: PANAMA CITY, FL
Zip Code: 32407-7001
Country: UNITED STATES
 
Record
SN01266466-W 20070406/070404221340 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.