Z -- Modification and upgrade to existing sewage treatment plant unit #2 at Seven Points Recreation Area, Raystown Lake Project, PA

Notice Date
4/11/2007
 
Notice Type
Modification
 
NAICS
237110 — Water and Sewer Line and Related Structures Construction
 
Contracting Office
US Army Corps of Engineers, Baltimore, 10 South Howard Street, Baltimore, MD 21203
 
ZIP Code
21203
 
Solicitation Number
W912DR-07-B-0008
 
Response Due
4/19/2007
 
Archive Date
6/18/2007
 
Small Business Set-Aside
N/A
 
Description
The following questions were submitted. The answers follow each question. Please also note that Amendment #2 was mistakenly issued as Amendment #1. There are currently two amendments that need to be acknowledged. Question 1. C.1.2.2 notes that the Air diffuser system from the main air supply to the aeration tank is to be removed and replaced. There are 5ea diffuser assemblies in the aeration tank and 2ea diffuser assemblies in the sludge digester and storage tank. It appears that 2ea diffuser assemblies in the sludge digester and storage tank are not being removed and replaced. Please confirm. Answer 1: All Diffusers Are to be removed and Replaced Question 2. Please clarify the extent of the removal and replacement. Does it include all piping from the 8 inches CIMJ Air Main or only the air piping from the air valves to the diffusers? I assume the air valve will remain as they are not specifically called out as being removed and replaced? Answer 2: The Piping will only be removed and replaced from the air valves to the diffusers. All the valves in this piping are gate valves they will be replaced with ball valves. Question 3. C.2.6 requires the deep bed sand filter media to be replaced per the manufacturer's instructions; however, the manufacturer is not given. Please supply the original manufacturer of the equipment. Also, we can only be held to the size limits s hown on page 32 of 36 and this information does not seem to be enough to assure proper operation of the system. Answer 3: The original manufacture is LYCO. The Specification listed on Page 32 were taken directly from the operation manual and this is what the contractor will be held to and is what is needed for proper operation.
 
Place of Performance
Address: Seven Points Recreation Area Raystown Lake Project Hesston PA
Zip Code: 16647
Country: US
 
Record
SN01271254-W 20070413/070411221440 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.