SOLICITATION NOTICE

41 -- 20 Ton Air Cooled Condensing Unit

Notice Date
4/19/2007
 
Notice Type
Solicitation Notice
 
NAICS
423730 — Warm Air Heating and Air-Conditioning Equipment and Supplies Merchant Wholesalers
 
Contracting Office
Department of the Navy, Naval Supply Systems Command, FISC NORFOLK ACQUISITION GROUP, CODE 200 1968 GILBERT STREET, SUITE 600, NORFOLK, VA, 23511-3392, UNITED STATES
 
ZIP Code
00000
 
Solicitation Number
Reference-Number-N4008507RC0110condensing
 
Response Due
4/2/2007
 
Archive Date
5/19/2007
 
Point of Contact
Fannie Richardson, Contract Specialist, Phone 757-443-1398, Fax 757-443-1424,
 
E-Mail Address
fannie.richardson@navy.mil
 
Description
The Government intends to procure 2 each, 20 ton air cooled condensing units, Trane brand, Mod #RAUCC20EB, and 1 each 71/2 ton unitary split system, Trane brand, model TTA090A300. The specification are as follows: 20 TON UNIT- 200V, 60 HERTZ, 3 PHASE, NO SYSTEM CONTROL, STANDARD AMBIENT CONTROL, UL/CSA APPROVAL SUCTION SERVICE VALVE, UNIT NEOPRENE ISOLATORS (FLD), REFRIGERANT SPECIALITIES INCLUDING: SUCTION LINE: DRIER SHELL & CORE, ACCESS PORTS W/SCHRAEDER VALVE, FROSTAT KIT, 2 BALL VALVES, LIQUID LINE: DRIER SHELL & CORE, SOLENOID VALVE & COIL, SIGHT GLASS, ACCESS PORT W W/SCHRADER VALVE, (2) BALL VALVES, THERMAL EXPANSION VALVES, The contractor shall provide the standard commercial warranty. . CAPACITY ?Split system air conditioning units (large), TAA air condensing outdoor unit, 7 1/2 TON NOMINAL COOLING, SINGLE COMPRESSOR - R22,208-230 VOLT 3PH 60 HERTZ, 1 LOW AMBIENT IF NO HGBP OR RELIATEL (FLD) and COIL GUARD KIT (FLD). The Government will install the equipment, but the contractor shall inspect the equipment for function ability when called to do so ALL ACCESSORIES MUST BE FIELD INSTALLED BY THE MECHANICAL CONTRACTOR. DISCONNECT SWITCHES, REFRIGERANT SPECIALITIES, R-22, REFRIGERANT PIPING, SIGHT GLASSES, BALL VALVES, AUXILIARY DRAIN PAN, EQUIPMENT SUPPORTS, DUCTWORK, MIXING PLENUM, EXTRA FILTERS, FLEX CONNETORS, CONTROLS, THERMOSTATS, HUMIDISTATS, CONTROLS WIRING, SMOKE DETECTORS, AIR BALANCING, CONDENSER COIL CORROSION PROTECTION (PHENOLIC COATINGS), ARE NOT INCLUDED. MAXIMUM REFRIGERANT LINE RUN 80 FEET LEAK CHECK, EVACUATION, AND REFRIGERANT CHARGING IS NOT INCLUDED. This office will no longer issue a hard copy of the Request For Quote (RFQ); therefore, a copy can be obtained from website https://www.neco.navy.mil. By submitting an offer, the vendor is self-certifying that neither the requestor nor the principal corporate officials and owners are currently suspended, debarred, or otherwise ineligible to receive contracts from any federal agency. Failure to do so may represent grounds for refusing to accept the offer. By submission of an offer, the contractor acknowledges the requirement that a prospective awardee must be registered in the CCR database prior to award, during performance, and through final payment of any contract resulting from this RFQ, except for awards to foreign vendors for work to be performed outside the United States. Lack of registration in the CCR database will make a contractor ineligible for award. Contractors may obtain information on registration and annual confirmation requirements by calling 1-888-227-2423, or via the Internet at https://www.bpn.gov. The RFQ shall be posted on or before 23 Apr 07.
 
Record
SN01277283-W 20070421/070419221521 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.