Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MAY 04, 2007 FBO #1985
SOLICITATION NOTICE

59 -- X-RAY DIFFRACTION SYSTEM

Notice Date
5/2/2007
 
Notice Type
Solicitation Notice
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
NASA/Lyndon B. Johnson Space Center, Houston Texas, 77058-3696, Mail Code: BH
 
ZIP Code
00000
 
Solicitation Number
NNJ07198026R
 
Response Due
5/18/2007
 
Archive Date
5/2/2008
 
Small Business Set-Aside
N/A
 
Description
NASA/JSC has a requirement for an updated PANalytical X-Ray Diffraction System to accomplish the analytical goals of the Astromaterials Research and Exploration Science Directorate (ARES). NASA/JSC intends to purchase this X-Ray Diffraction System from PANalytical Inc. PANalytical Inc. is the only source to provide the PANalytical X-Ray Diffraction System that can meet the specific requirements for NASA/JSC ARES Directorate. This system meets agency unique requirements. ARES requires an X-Ray Diffraction System with high speed detector for high resolution phase analysis. Specific requirements for this system include: DIFFRACTOMETER CONSOLE - An instrument enclosure with sufficient space for single or dual goniometer. Enclosure has fully interlocked double sliding doors (18mm lead acrylic) for normal access. All direct radiation areas 12mm steel. - Hinged back panels for improved access during system maintenance or reconfiguration. - A high stability, solid state 3 kW x-ray generator. Generator settings controlled directly by the software including automated tube "burn-in", ramping of tube power and standby modes at measurement conclusion. Maximum settings of 60kV, 60mA. Generator communicates directly with x-ray tube to ensure that maximum allowable power ratings are never exceeded. Variations in HV <0.01% per 10% mains variation. - Microprocessor for control of 24 DC motors, multiple stepper motors, 4 detectors and 3 shutters simultaneously. - Mounting rack for accessories such as temperature controllers and detector electronics. - Dynamic real time status display of operating conditions and parameters including angular positions, counts, kV and mA settings. CERAMIC TUBE CU LFF - High-power X-Ray tube for X-Ray Diffraction. Characteristics including: body of ceramics, Cu anode, Long Fine Focal spot (LFF), two exit beam ports with Be window providing 1 line foci and 1 point foci. Tube prepared to rotate from line to point position and is equipped with line/point and anode type recognition. High Power: 60 kV, 2.2 kW. CERAMIC TUBE CO LFF - High-power X-Ray tube for X-Ray Diffraction. Characteristics including: body of ceramics, Co anode, Long Fine Focal spot (LFF), two exit beam ports with Be window providing 1 line foci and 1 point foci. Tube prepared to rotate from line to point position and is equipped with line/point and anode type recognition. High Power: 60 kV, 1.8 kW. Quick disconnects for water lines for a 2nd Tube PEDESTAL VERTICAL GONIOMETER Theta-Theta - High performance theta/theta goniometer. Both theta drives independently positioned using the unique Direct Optical Position Sensing (DOPS) servo control system. Specifications are: accuracy +/- 0.0025 degrees, reproducibility +/- 0.0001 degrees, scan speed 0.001 to 1.27 degrees per second, slew speed 10 degrees per second, minimum step size 0.0001 degree. Two theta measuring range 0 to 167 degrees, and goniometer radius variable from 130 to 230 mm. THETA-THETA TUBE INTERFACE, 150MM STAGE INTERFACE FOR THETA-THETA APPLICATIONS Incident Beam Optics: PROGRAMMABLE DIVERGENCE SLIT PROGRAMMABLE DIVERGENCE SLIT, PREFIX - Software controlled primary beam divergence slit mechanism that provides automatic variable slit and fixed slit modes of operation. The variable mode allows for illuminated sample irradiation from 0.5 to 20 mm in 0.5 mm increments. The fixed slit mode allows for 1/32,1/16, 1/8, 1/4, 1/2, 1, 2 and 4 degree slit sizes. Beam masks of 2, 5, 10,15 and 20 mm. INCIDENT ANTI SCATTER SLIT DEVICE - Incident beam anti-scatter device to be mounted on fixed or programmable divergence slits. Divergence slits of 1/32 , 1/16 , 1/8 , 1/4 , 1/2 , 1 , 2 and 4 degree. MDCD control Cable to connect motor controlled optical modules to the multiple DC motor driver board. SOLLER SLIT 0.04 RADIANS - Soller slit 0.04 radians for incident and diffracted beam. SOLLER SLIT 0.02 RADIANS -Soller slit 0.02 radians for incident and diffracted beam. Diffracted Beam Optics PROGRAMMABLE ANTI-SCATTER SLIT - Programmable anti-scatter diffracted slit module. Variable mode that allows for illuminated sample irradiation from 0.5 to 20mm in 0.5mm increments. The area of illumination which can be offset from the center of the sample. The fixed slit mode allowing for 1/32, 1/16, 1/8, 1/4, 1/2, 1, 2 and 4 degree slits sizes. MDCD control Cable to connect motor controlled optical modules to the multiple DC motor driver board. DETECTOR DETECTOR, ELECTRONICS & PREFIX INTERFACE INTERFACE PASS SOLLER SLIT, LARGE, 0.04 RADIANS SOLLER SLIT, LARGE, 0.02 RADIANS BETA FILTER NICKEL Set of three Beta filters: - Fe for Co, V for Cr- and Zr for Mo-radiation. The filters can be used as incident beam filter or as diffracted beam filter. MONOCHROMATOR - Diffracted beam monochromator for use with detector and Cu radiation. 15 Position Sample Changer: SAMPLE CHANGER 15 POSITION SAMPLE SPINNER STAGE BOARD SPINNER CHANGER SAMPLE HOLDER BOTTOM, SET OF 3 SAMPLE HOLDER TOP, 27MM, SET OF 3 SAMPLE HOLDER TOP, 16MM, SET OF 3 SAMPLE HOLDERS INSERT 32MM (SET OF 3) SAMPLE HOLDERS INSERT 32MM (SET OF 3) INSERT 32MM LOW BACKGROUND (SET OF 2) SAMPLE PREPARATION STATION - Powder Sample Preparation Kit including sample preparation table, sample holder ring, powder press block or piston, a dusting brush and a Stanley knife blade. Software DATA COLLECTOR Software - Data collection software featuring XML file format. - APP - Automatic Processing Program - for batch scripting of data collection, analysis and reporting functions for automatic sample analysis - Data Viewer - a graphical display package for display (no analysis) and overlay, annotation, file format conversion, and printing or electronic reporting of multiple file formats - Windows Explorer tools, which include thumbnail viewing of data and automatic launching of data files into analysis software. - Software License allows installation on up to 10 CPU?s. HIGHSCORE SOFTWARE-ADVANCED SEARCH MATCH SOFTWARE - Phase software designed to solve complex phase mixtures. Including the following features: - 3RD generation Search-match algorithm- combines peak and profile data, individually or simultaneously - Auto-residue scoring-fast multi phase solutions - Automatic Phase ID - Semi quantitative RIR method - Crystallite size calculation - Advanced reporting functions-direct to MS software - Graphics for examining, displaying, and editing diffractograms - Supports user and/or ICDD reference databases - Includes batch processing-completely automate routine tasks - Automation ready - can be launched from a command prompt - Pattern Cluster Analysis for sorting scans - File format based on XML technology - License allows multiple software installations Software package to upgrade from HighScore to HighScore Plus Tool for indexing, lattice refinement and Rietveld calculations. Contains large amount of supporting functions to manipulate your data. ASCII and binary data formats of all major suppliers supported. ? Crystallography: Containing four indexing methods, the subsequent unit cell refinement plus a symmetry explorer and the symmetry reduction. ? Rietveld: A powder or neutron data refinement running either in automatic, semiautomatic or manual mode. Includes quantitative phase analysis and powder pattern simulation. ? Auxiliary functions and tools: A comprehensive set of pattern treatment functions and correction methods. The tools include a periodic table with X-ray relevant data and three calculators. Searching and displaying of ICDD or your own reference patterns. ? Expanded Cluster analysis on an unlimited number of datasets. LICENSE, PDF2, NEW USER ICDD PDF-2 license for new user, including database on CD-ROM. ICSD DATABASE FOR HSPLUS ICSD database to be used with HighScorePlus version 2.2 or higher. Database loadable on more than one computer and does not expire. LINE PROFILE ANALYSIS Software PROFIT WIN Software Computer, 20? Flat Panel Display & 24? Flat Panel Display, Dual Serial Port & printer with cable Training TRAINING AT CUSTOMER SITE 2 DAYS, 2 additional days plus vendor site training for XRD school Applications training for XRD users Peripheral equipment Dual pump water chiller (R250 air-cooled WATER CHILLER or equivalent) REACTION CHAMBER XRK 900 SPINNER Anton Paar XRK 900 reaction chamber equipped with Be windows (with spinning sample stage), TCU750 temperature controller included. COMPUTER CONTROL HEIGHT XRK XRK SPINNING SAMPLE HOLDER: CLOSED CERAMIC Closed spinning sample holder for the X-Ray Reactor Chamber types XRK 600 and XRK 900, making it possible to operate the XRK in vacuum. Consequently the reaction gas cannot flow through the sample. The sample holder is made of glass ceramics. XRK SPINNING SAMPLE HOLDER: OPEN CERAMIC Open spinning sample holder for the X-Ray Reactor Chamber types XRK 600 and XRK 900, having a sieve-like bottom so that the reaction gas can flow through the sample. With this type of holder the XRK chamber cannot be used in vacuum. The sample holder is made of glass ceramics. The connector for gas discharge made of stainless steel. PAAR INSTALLATION KIT Installation kit for Anton Paar non-ambient chambers which need external water cooling. Contains couplings and accessories for the cooling water hoses as well as an extension cord. Kit contains enough material for cooling water connections of two non-ambient chambers requiring water cooling. CABLE For use with high temperature cameras. Serial cable connects the TCU to the host computer via a COM port and provides a communication link to program the temperature ramping. Camera with low temp attachment TTK-450 CAMERA WITH CONTROLLER Low Temperature Camera System TTK 450. Includes camera TTK 450, the temperature control unit TCU 100, and a simple water control device. COMPUTER CONTROL HEIGHT TTK TTK-450 LIQUID NITROGEN DELIVERY EQUIPMENT Low temperature equipment for Low Temperature Camera System TTK 450. Includes Liquid Nitrogen Control Unit (AP58320) for the suction of liquid nitrogen, with built-in diaphragm pump for manual or automatic dosage of the nitrogen flow, and the connector to the TTK camera for the supply of liquid nitrogen. Parts for installation included. DEWAR VESSEL 5L, cable, paar installation kit THC TEMPERATURE HUMIDITY CHAMBER SYSTEM THC TEMPERATURE HUMIDITY CHAMBER SYSTEM Humidity Camera System including complete camera THC and the temperature control unit TCU50. Includes heated delivery line, humidity controller. COMPUTER CONTROL HEIGHT TTK VTI HUMIDITY GENERATOR RH-200 humidity generator supplies a constant flow of relative humidity of water vapor, or organic vapor. PC Control board and humidity software included to control all functions eliminating the need for constant monitoring of flow, temperature and humidity, and displays real time graphs of RH versus time. The RH can deliver any flow rate between 0-100cc/min at temperatures up to 60 degrees C. Requires dry air or nitrogen supply at 2-100 Psi. THC CAMERA TEMPERATURE BATH Neslab temperature bath for THC temperature humidity chamber system. Temperature bath allows for heating of humidity delivery hose and THC camera walls to prevent condensation. Cable, installation kit, Sample Holder TTK and THC (0.2 mm & 0.8 mm deep) VACUUM SYSTEM Vacuum equipment for TTK 450 and XRK 900. Included are: pre-vacuum pump; vacuum measuring devices; parts for installation. 1 year full warranty On-site installation The Government intends to acquire a commercial item using FAR Part 12. Interested organizations may submit their capabilities and qualifications to perform the effort in writing to the identified point of contact not later than 4:30 p.m. local time on May 18, 2007. Such capabilities/qualifications will be evaluated solely for the purpose of determining whether or not to conduct this procurement on a competitive basis. A determination by the Government not to compete this proposed effort on a full and open competition basis, based upon responses to this notice, is solely within the discretion of the government. Oral communications are not acceptable in response to this notice. All responsible sources may submit an offer which shall be considered by the agency. An Ombudsman has been appointed. See NASA Specific Note "B". Any referenced notes may be viewed at the following URLs linked below.
 
Web Link
Click here for the latest information about this notice
(http://prod.nais.nasa.gov/cgi-bin/eps/bizops.cgi?gr=D&pin=73#124442)
 
Record
SN01286276-W 20070504/070502230005 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.