Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF MAY 16, 2007 FBO #1997
MODIFICATION

Z -- Replace Failed SCADA System. This project replaces the remote monitoring and control system, Supervisory Control and Data Acquisition (SCADA), for the primary electrical power distribution system located at WPAFB

Notice Date
5/14/2007
 
Notice Type
Modification
 
NAICS
238210 — Electrical Contractors
 
Contracting Office
1940 Allbrook Drive Suite 3 Wright-Patterson AFB, OH
 
ZIP Code
00000
 
Solicitation Number
FA8601-07-050011
 
Response Due
5/20/2007
 
Archive Date
10/1/2007
 
Small Business Set-Aside
N/A
 
Description
The Air Force is seeking sources for a potential 100 percent set-aside for HUBZone, or Service Disabled Veteran Owned Small Business (SDVOSB) concerns. IF ADEQUATE RESPONSES ARE NOT RECEIVED, THE ACQUISITION MAY BE SOLICITED ON AN UNRESTRICTED BASIS. This is a sources sought for planning purposes only. TITLE /DESCRIPTION: Replace Failed SCADA System, Project Number 050011. This project replaces the remote monitoring and control system, Supervisory Control and Data Acquisition (SCADA), for the primary electrical power distribution system located at WPAFB. This system consists of power sensors, relays, remote terminal units, and the interconnecting control conductors in 9 substations located throughout the base. It also consists of a front end computer system located in one central facility along with other remote monitoring sites. This project requires very specialized equipment and computer programming to result in a fully functional SCADA system. The SCADA system monitors the entire primary electrical distribution system, and allows for complete control of that system. DOLLAR VALUE: $1,000,000 to $5,000,000 SPECIAL REQUIREMENTS/CONCERNS: The SCADA system monitors and controls the primary electrical distribution system for all of WPAFB. The contract requires the installation of highly specialized hardware controlled by custom written computer code. It requires the correct installation of thousands of control conductors, hundreds of relays, and hundreds of sensors. Mistakes can cause unscheduled power outages to multiple facilities throughout the base, and can be difficult to trace to eliminate. Each unscheduled power outage has a large financial impact to the base, and the primary electrical distribution system is the most critical utility system of all. PERFORMANCE PERIOD: 365 days Prime contractors who are HUBZone and/or SDVOSB and who intend to submit a bid for this solicitation MUST submit the following by 2:00 p.m. (local Dayton time) on 21 May 2007: (1) a positive statement of your intention to submit a bid for this solicitation as a Prime Contractor; (2) date of HUBZone and/or SDVOSB certification; (3) listing of experience in work similar in type and scope that you identified to include contract numbers, project titles, dollar amounts, and points of contact with their current phone numbers; (4) evidence of capability to be bonded for bid, performance and payment bonds; and (5) if you are a HUBZone considering a joint venture, you will need to provide proof that this consideration has been forwarded to the cognizant SBA office for approval. Firms interested should provide the above documentation, e-mail and faxed responses will be accepted. All of the above must be submitted in sufficient detail for a decision to be made on the availability of interested HUBZone or SDVOSB concerns. Responses shall be limited to 5 pages. Failure to submit all information requested would result in a contractor being considered 'not interested' in this requirement. The mailing address for responses is 88 CONS/PKC, 1940 Allbrook Dr, Ste 3, Wright-Patterson AFB, OH 45433-5309. For more information on "Replace Failed SCADA System. This project replaces the remote monitoring and control system, Supervisory Control and Data Acquisition (SCADA), for the primary electrical power distribution system located at WPAFB", please refer to: https://www.pixs.wpafb.af.mil/pixs_solicitation.asp?id=5238
 
Web Link
Replace Failed SCADA System. This project replaces the remote monitoring and control system, S
(https://www.pixs.wpafb.af.mil/pixs_solicitation.asp?id=5238)
 
Place of Performance
Address: Wright-Patterson AFB, OH
Zip Code: 45433
Country: USA
 
Record
SN01294039-W 20070516/070514220509 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.