SOLICITATION NOTICE
J -- Prepare and Prime Weather Deck Surfaces
- Notice Date
- 6/8/2007
- Notice Type
- Solicitation Notice
- NAICS
- 336611
— Ship Building and Repairing
- Contracting Office
- Department of Homeland Security, United States Coast Guard (USCG), Commanding Officer (fcp), USCG Integrated Support Command Cleveland, 1240 East 9th Street, Cleveland, OH, 44199-2060, UNITED STATES
- ZIP Code
- 00000
- Solicitation Number
- HSCG30-07-Q-C79027
- Response Due
- 6/20/2007
- Archive Date
- 7/5/2007
- Description
- WORK ITEM 1: Prepare and Prime Weather Decks <CMP> 1. SCOPE 1.1 Scope. This work item describes the requirements for the Contractor to remove old painting systems and perpare and prime weather deck surfaces with Amercoat 137 Commencing on or about 18 June 2007 and to be completed by 25 June 2007, (Contact Ameron Reprsentaive for alternatate primers)shown on Coast Guard Drawing 225 WLB 601-001 D Sheet 5, which include the following: 1.1.1 Foc?sle. 1.1.2 Port Aircastle. 1.1.3 Starboard Aircastle. 1.1.4 Port Boat deck. 1.1.5 Conn Boat Deck. 1.1.6 Starboard Boat Deck. 1.1.7 Port Bridge Wing. 1.1.8 Conn. Bridge Wing. 1.1.9 Flying Bridge Wing. 2. APPLICABLE DOCUMENTS Coast Guard Maintenance and Logistics Command Atlantic (MLCA), Standard Specification 0000_STD, 2006 Edition, General Requirements Coast Guard Commandant Instruction (COMDTINST) M10360.3 (Series), Coatings and Color Manual Coast Guard Drawing 225B WLB 601-002, Rev C, Booklet of General Drawings 3. REQUIREMENTS 3.1 General. 3.1.1 Protective measures. The Contractor shall protect non-affected vessel?s equipment, components, and spaces during surface preparation and coating application procedures for primer application, (Amercoat 137 or proper alternative). as specified in paragraph 3.11.4(Protective measures) in Std Spec 0000_STD. 3.2 Preservation particulars. The Contractor shall preserve the designated surfaces, including bitt and chock foundations, machinery rack guards and machinery foundations, hatches and hatch guards, stanchion sockets, vent pipes, angle coaming area, and approximately six inches up all adjacent vertical surfaces; use the system specified for ?Weather Deck (Weather Deck, Non-Skid, MIL-SPEC Coating for Steel or Aluminum, Type, Type III? in COMDTINST M10360.3, Appendix A (Cutters and Boat Exterior Painting Systems). 3.3 Substrate inspection. After completion surface preparation and before coating application, the Contractor shall perform a visual inspection of the prepared substrate, and submit a CFR. 4. QUALITY ASSURANCE 4.1 In-process quality control measures. The Contractor shall abide by all the safety, preservation, and quality control requirements specified in Std Spec 0000_STD, paragraph titled ?General preservation requirements. NOTICE! Surfaces being preserved are considered ?critical-coated surfaces?. 5. NOTES Cutter will apply non-skid after acceptance of contract. NOTE NO PHONE CALLS WILL BE ACCEPTED SUBMIT QUOTES VIA E-MAIL LISTED BELOW OR FAX 216-902-6380
- Place of Performance
- Address: USCGC ALDER(WLB-216), 1201 Minnesota Ave, Dulth, MN
- Zip Code: 55802
- Country: UNITED STATES
- Zip Code: 55802
- Record
- SN01313908-W 20070610/070608220906 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |