Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JUNE 16, 2007 FBO #2028
SOLICITATION NOTICE

L -- Re-Commissioning of HAV systems

Notice Date
6/14/2007
 
Notice Type
Solicitation Notice
 
NAICS
811219 — Other Electronic and Precision Equipment Repair and Maintenance
 
Contracting Office
Department of Health and Human Services, Indian Health Service, Navajo Area Office, PO Box 9020, Window Rock, AZ, 86515, UNITED STATES
 
ZIP Code
00000
 
Solicitation Number
RFQ00F70012EDT
 
Response Due
6/29/2007
 
Archive Date
6/29/2007
 
Description
This is a combined synopsis, request for quote will not be issued Government Scope of Work for Re-Commissioning HVAC systems at Fort Defiance Indian Hospital. 1. Review existing documentation (including but not limited to equipment O&M manuals and Johnson Controls Metasys program) to gain an understanding of the design intent of the HVAC system and overall familiarity of the building. 2. Interview key personnel to obtain information on system performance issues that have been experienced. 3. Investigate current operation of all air handlers, central plant equipment, water distribution systems, representative terminal devices and relative associated control equipment and document current operational problems. 4. Perform a Re-Commissioning assessment of the ten (10) air-handling systems. 5. Perform a Re-Commissioning assessment of a small sample (~5-10%) of typical terminal units in the building from a total of 447 variable air volume (VAV) boxes. Focus on units in areas where there are known issues. 6. Perform a Re-Commissioning assessment of the Central Plant to include the two (2) 350 TON chillers, two (2) 350 HP hot water boilers, three (3) 20 HP steam boilers, two (2) cooling towers, 14 humidifiers, and associated hydronic distribution systems. 7. Attend 2 Project Meetings while on-site (Entry and Exit meetings with Executive Committee) 8. Identify findings and issues with system performance. Provide a written report of findings. 9. Identify areas of operations/set points/control sequences that need to be changed and provide updated set points/sequences of operation for the major systems commissioned, and incorporate them into the Johnson Controls METASYS (Building Automation System). 10. Analyze further issues and provide a report with a list of recommendations and corrective actions with cost estimates. 1JOB $_____________
 
Place of Performance
Address: FORT DEFIANCE INDIAN HOSPITAL, PO BOX 649, (CORNER OF ROUTES N12 & N7, FORT DEFIANCE AZ., 86504,
Zip Code: 86504-0649
Country: UNITED STATES
 
Record
SN01318746-W 20070616/070614220605 (fbodaily.com)
 