SOLICITATION NOTICE
29 -- AC Dynamometer
- Notice Date
- 6/19/2007
- Notice Type
- Solicitation Notice
- NAICS
- 333618
— Other Engine Equipment Manufacturing
- Contracting Office
- TACOM - Warren Acquisition Center, ATTN: AMSTA-AQ-AMB, E Eleven Mile Road, Warren, MI 48397-5000
- ZIP Code
- 48397-5000
- Solicitation Number
- TARRES09907
- Response Due
- 6/22/2007
- Archive Date
- 8/21/2007
- Small Business Set-Aside
- Total Small Business
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. See note 10. The United States Army Tank and Automotive Research, Development, and Engineering Center (TARDEC) in Warren, MI has a requirement for the following: The Hybrid Electric Mobility team requires an AC dynamometer with associated dynamometer controls and data acquisition system for motor/generator and motor drive controls testing. Unit must be a four quadrant AC dynamometer and function dynamically betwee n quadrants. The dynamometer must be an active dyne, specifically with the ability to transition dynamically between quadrants. Dynamic transition between quadrants means the dynamometer system can simulate a vehicle load climbing up a hill (requiring mot oring torque) then peaking and going down the hill (requiring a generating or braking torque) thereby transitioning between two quadrants on-the-fly. The dyno system should be fully programmable, regenerative and upgradeable. This system is to be inte grated or installed into test cell 10 of building 212 and interface with available building electrical facilities. Following lists the requirements of the system: AC dynamometer specifications/requirements: Base Speed 2000 Rpm Max Speed in range of 10,000 - 12000 Rpm Max Torque @ base 900 Lb-Ft Constant HP above Base 350 Hp Trunion Mounted Air cooled In line Torque measurement disk Dynamometer controller specifications/requirements: Must be AC line regenerative capable Dynamometer Controller modes: Speed/Torque Closed loop Vector control Relay Logic as required. E-Stop, Fault Reset, Pilot Light annunciations such as: Power On, Drive on etc. Data Acquisition/control system specifications/ requirements: National Instruments with Lab view SW Dig Inputs 8 Relay Output 8 T/C inputs 32 RTDs 8 HS Analog In 16 (resolution 16 bits) HS Analog out 2 (resolution 16 bits) PC based cpu mounted in a free standing enclosure Operator control station mounted in a control room separate from the dynamometer
- Place of Performance
- Address: TACOM - Warren Acquisition Center ATTN: AMSTA-AQ-AMB, E Eleven Mile Road Warren MI
- Zip Code: 48397-5000
- Country: US
- Zip Code: 48397-5000
- Record
- SN01322536-W 20070621/070619223501 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |