Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JULY 14, 2007 FBO #2056
SOLICITATION NOTICE

Y -- Physical security protection system-technical isolation zone.

Notice Date
7/12/2007
 
Notice Type
Solicitation Notice
 
NAICS
237990 — Other Heavy and Civil Engineering Construction
 
Contracting Office
Department of Energy, Los Alamos National Laboratory (DOE Contractor), Los Alamos, PO Box 1663 MS: C334, Los Alamos, NM, 87545, UNITED STATES
 
ZIP Code
00000
 
Solicitation Number
54650-001-07-CB-
 
Response Due
8/16/2007
 
Archive Date
8/17/2007
 
Description
Los Alamos National Laboratory (LANL), operated by Los Alamos Nation Security, LLC for the Department of Energy's National Nuclear Security Administration (NNSA), is preparing a solicitation to provide construction services to replace the existing physical security protection system at a major nuclear facility at the Laboratory. The physical security work consists of the following subsystems that will be assembled into one of two procurements: - Technical Area Isolation Zone (TAIZ) - Perimeter Intrusion Detection, Assessment, and Delay System (PIDADS) - East Entry Control Facility (ECF) - West Vehicle Access (WVA) - Temporary Visitors Center (TVC) - Airborne Mitigation System (AMS) - Utility Building (UB) - Utility Trunk (UT) This procurement consists of the TAIZ, PIDADS, UB, UT, and AMS: 1. TAIZ: Construct approximately 6,600 linear feet of an outer security boundary and prepare the enclosed land to create a technical area isolation zone. This includes removing a limited number of existing structures. 2. PIDADS: Construct approximately 4,400 linear feet of a Perimeter Intrusion Detection, Assessment, and Delay System. Remove the existing system that is being replaced. 3. UB: Construct a utility building to enhance the electrical and communication needs of the new facilities. The UB will include an auxiliary generator and uninterruptible power supplies. 4. UT: Construct an electrical power and communications duct bank alone the inside perimeter of the PIDADS. This utility trunk will consist of concrete encased raceways and associated conductors with manholes and hand holes at appropriate locations around the PIDADS perimeter. 5. AMS (Option): Install exterior detection equipment and lighting to cover the roof of a facility approximately 140,000 square feet in size. In addition, install three hardened security booths approximately 150 square feet in size and three platforms for placement of weapons by others. Power, communications and controls is required from an existing Central Alarm Station to each of the hardened booths and platforms. This procurement will use a combined process. The Request for Qualifications (RFQ) will be included in the Request for Proposals (RFP). The qualifications categories are experience, safety, quality, and financial. - Experience- Furnish two examples of similar type construction projects that Respondent has finished in the last ten years with a contract value of greater than $20M each that have measurable comparability to the RFP. - Safety- Experience Modification Rate: maximum allowable average of 1.0 or less; Total Recordable Injury/Illness Case rate: maximum allowable average of 3.2 or less; and Lost Workday Case Rate: maximum allowable average of 1.4 or less. - Quality- Submit a completed "10 CFR 830.120 Subpart A and DOE Order 414.1C Quality Assurance Compliance Survey". In addition, provide a copy of Respondent's corporate QA Program document. - Financial- Provide evidence of financial stability, including audited balance sheets (or annual reports with similar data) for the past three years or a letter from a bonding company stating that Respondent can be bonded for a project of this size. The project magnitude is estimated to be approximately $80-90 million. LANL expects to issue an RFP on or about August 16, 2007. The subcontract award is expected approximately February 2008. Construction is expected to start approximately March 2008 and complete no later than September 2011. This project has been determined to be Management Level 3. The award of this contract is contingent upon the receipt of approval and funding from the Department of Energy. A portion of the Capital funding for this project is currently available, with the remainder to become available early in each fiscal year of the project's duration. LANL intends to award a firm, fixed-price contract to the successful construction firm that best meets the Laboratory's goals and objectives contingent upon availability and approval of these funds. If you are interested in participating in this solicitation and want your company's name added to the bid list, submit your company name, contact, address, phone number, and business size to: hayd@lanl.gov.
 
Place of Performance
Address: Los Alamos, New Mexico
Zip Code: 87545
Country: UNITED STATES
 
Record
SN01340439-W 20070714/070712220647 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.