Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JULY 15, 2007 FBO #2057
MODIFICATION

Z -- HVAC Administrative Building

Notice Date
7/13/2007
 
Notice Type
Modification
 
NAICS
238220 — Plumbing, Heating, and Air-Conditioning Contractors
 
Contracting Office
Department of Agriculture, Forest Service, R-8/SRS Eastern Administrative Zone, 200 WT Weaver Blvd., Asheville, NC, 28804, UNITED STATES
 
ZIP Code
00000
 
Solicitation Number
AG-4660-S-07-0012
 
Response Due
8/13/2007
 
Archive Date
9/30/2007
 
Point of Contact
Margaret Yeaton, EAZ Acquisition Contract Specialist, Phone 803-725-0239, Fax 803-725-1807, - Cynthia Korman, Purchasing Agent, Phone 803-725-0251, Fax 803-725-1807,
 
E-Mail Address
myeaton@fs.fed.us, cpossee@fs.fed.us
 
Description
Site visit to be held on 30 Jul, 2007. Offerors planning to attend the Site Visit conference must contact Margie Yeaton (802) 725-0239 myeaton@fs.fed.us or Kevin Korman (803) 725-8855 kkorman@fs.fed.us before 25 Jul 2007 , 4:00 p.m. The information needed to process a badge request and directions to the site are included in the solicitation. The USDA Forest Service Savannah River has a requirement for HVAC system in Administrative building. The project consists of installation of a replacement HVAC system for an administrative building of approximately 7000 square feet for the US Forest Service located on the Savannah River Site. The work will include removal of the present Chiller, pumps, controls, Fan Coil Units in office spaces and removal of exposed chilled water piping and electric wiring within the building which support the existing HVAC system. Replace with a HVAC system composed of dual heat pump system with individualized Fan Coil Units in each office space and two dehumidification units. The new system will require new electrical rewiring, BC controller that allow individualized demands to be sent to each office with high and low pressure lines and minor office reconfiguration for the new mechanical and dehumidification systems. Work will be done in an occupied office space and must be planned to keep disruption of office activities to a minimum. Work is planned to be done in late fall or winter when cooling demands are minimal. The contractor shall install an Air-cooled Variable Capacity (VFR) Type Multiple Split Heat Pump System with Outdoor and Indoor units. The system and all units shall be "Mitsubishi Electric", "HVAC Advance Products" of the "CITY MULTI" system, "R2-Series or an approved manufacturer that is equal to the system. The Contractor shall provide to the Government prior to award any proposal to an equal as part of the evaluation process for award. The proposed equal system shall be a 2 pipe refrigerant design system only (3 pipe systems will not be permitted). Complete details of the proposed system, with all components must be provided (equal in detail of the specifications of the Mitsubishi system in this solicitation) and presented with Contractor's proposal so it can be fully evaluated. The estimated construction cost is between $250,0000 and $500,000. The size standard is $13 million under NAICS code 238220. This is an unrestricted solicitation. Savannah River Site is a restricted access Government facility and vehicle searches are done on all vehicles entering the Site. No contraband items, such as guns, ammunition, drugs etc. are allowed on Site. A picture ID of persons entering the Site is required. A minimum of 72 hours is required to process any security badge requests for U.S. Citizens and up to 30 days could be required for non-U.S. citizens. Contractors should pay close attention to the deadlines to submit information required to gain access for site visit included in the solicitation. Offerors must register on the site in order to receive notification of changes to the solicitation. The offeror is responsible for monitoring this site for release of the solicitation and any subsequent postings. All interested parties must be registered with the Central Contractor Registration (CCR) as prescribed by FAR Clause 52.204-7 and ORCA. CCR can be obtained by accessing the Internet www.ccr.gov or by calling 1-888-227-2423. ORCA can be obtained by accessing the Internet, www.bpn.gov. Any questions concerning this solicitation, fax: (803) 725-1807 or contact telephone numbers indicated.
 
Place of Performance
Address: USDA Forest Service Savannah River, 1 mile inside Aiken barricade, SRS, Aiken SC
Zip Code: 29802
Country: UNITED STATES
 
Record
SN01341657-W 20070715/070713220528 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.