Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF JULY 26, 2007 FBO #2068
MODIFICATION

Y -- Modular Offices

Notice Date
7/24/2007
 
Notice Type
Modification
 
NAICS
332311 — Prefabricated Metal Building and Component Manufacturing
 
Contracting Office
Department of the Air Force, Air Force Materiel Command, WR-ALC, WR-ALC/PK Acquisition Opportunities 235 Byron St,, Warner Robins, GA, 31098-1611, UNITED STATES
 
ZIP Code
00000
 
Solicitation Number
Reference-Number-F3QCCM7051A0011
 
Response Due
8/6/2007
 
Archive Date
8/21/2007
 
Small Business Set-Aside
Total HUB-Zone
 
Description
Amendment 6: This requirement was synopsized/solicited as a FAR Part 12 acquisition. This is hereby amended to change the requirement to a FAR Part 36 (Construction) type acquisition and to add another modular office. This change is due to a funding issue and the addition of another modular office by the customer. Attachments include: Revised solicitation, FA8501-07-R-0031, eight(8)office SOW, one(1) office SOW, and wage determination. THIS IS A HUBZONE SETASIDE. SALIENT CHARACTERISTICS FOR PURCHASE OF EIGHT PORTABLE OFFICES SCOPE: The contractor shall provide all freight, labor, and equipment necessary to furnish and locate eight pre-assembled portable office units. One office unit shall be 12 L x 8 W and referred to as the "office". The office will be used as an in-plant office in a dry work area. Area of work is at Robins AFB, GA in Building 321. PRODUCT SPECIFICATIONS FOR THE "OFFICE": Each office will be an interior portable office constructed using manufacturer's standard products, and commercial off the shelf products for electrical power components, lighting fixtures, mechanical off-the-shelf products, hardware, windows, and flooring. Forkliftable floor for each office shall be constructed of material designed for a minimum 50 PSF live load. The floor will be a minimum of 7 inches high. Exterior walls for each office shall be of embossed metal exterior finish and shall be beige in color. All wall panels shall have a flame spread of less than 25 feet and shall be certified IAW ASTM E84. Ceiling for each office shall be acoustic tile type with two 2' x 4', 2-bulb florescent light fixtures. Ceiling shall be a standard height of eight feet. The door for each office shall be 36 x 72 minimum with a 2 x 3 wire reinforced solid glass window and a keyed lever type, grade 2 BEST lock cored knob set. Each door shall be left-hand, inward opening. Door shall have a full gasket around the entire frame to seal the room from outside noise, dust and temperature. Interior of door shall be finished to match the interior color of the walls. Exterior of door and casing shall be brown. Each office shall have one 46 x 27 wire reinforced solid glass window. See attached drawing for specific locations for door, window, and HVAC for each unit. Also the quantity of each type are as follows: Model A? QTY:1 Model B QTY:6 Model C QTY:1 The finish flooring for each office shall consist of a vinyl composite tile with 4 vinyl base molding. Sprinkler heads for each office shall be a standard temperature, quick response pendant style sprinkler for fire protection, flush mounted in the drop ceiling with a chrome bezel. It shall be a water type with connection piping run through the exterior roof to a height of between 18 and 24 above the roof. Schedule 40 black steel pipes shall be used for the sprinkler assembly and painted red. It shall be threaded at its termination for an easy connection to a water source. The sprinkler system shall be in accordance with National Fire Protection Association Code 13. The electrical service for each office shall consist of indoor circuit breaker type load center. See attached drawings for specific locations for the load centers. The load center shall be single phase, 120/240V circuit breaker panel with a main 60A breaker. The electrical package shall include (minimum) EMT concealed in the wall panel and attached to flush mounted receptacles and switches. The package shall include 1 wall switch for the lights, (5) 20A, 120V duplex receptacles, and one 20A, 250V receptacle for the HVAC unit (within 6 of HVAC unit). See attached drawings for specific locations for receptacles. The HVAC system for each office shall consist of a 120/208V, through the wall mounted heat pump with a minimum of 12000 BTU of cooling and 12000 BTU of heating capacity. See attached drawings for specific locations for HVAC units. Each office shall have 2 conduits exiting the roof; 1 for telephone lines and 1 for data lines. The telephone and data junction boxes shall be flush mounted on the walls at a maximum of 2 feet above the interior finished floor in the locations shown on the attached drawing. All electrical and equipment shall comply and be in accordance with the National Electrical Code, NEC (current edition). See attached drawings for specific locations for telephone and data outlets. The contractor shall provide an id plate for each office stating that the office meets the above stated fire standards as well as manufacturer name, model number, and date manufactured. The placard shall be attached inside in each above the door. Robins AFB personnel will provide utilities to the vicinity of the offices and make said utility connections. DELIVERY: The contractor shall deliver the offices 45 calendar days after the award of the contract. SITE PLACEMENT AND ANCHORAGE: Contractor shall place pre-assembled portable office units in Building 321 in an area designated by the project engineer at the time of delivery. SITE CLEAN-UP: Ensure that the areas around the portable offices as well as the areas inside the portable offices are cleaned of any trash or debris from manufacturing, shipping, or packaging, segregated by material type (i.e. cardboard, metal, trash), removed from the area or office, and placed in appropriate collection containers located in the yard of building 321. WORK SCHEDULE: Normal duty operations are from 6:00 am to 2:45 pm, Monday through Friday; except on holidays. The Contractor shall schedule delivery and all work during these hours. *************************************************************** SEE DRAWING ATTACHED
 
Place of Performance
Address: 78 CONS, 375 PERRY STREET, SUITE A, ROBINS AFB, GA
Zip Code: 31098-1672
Country: UNITED STATES
 
Record
SN01350546-W 20070726/070724221453 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.