Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF AUGUST 24, 2007 FBO #2097
MODIFICATION

54 -- FActory Mutual (FM) Approved Safety Storage Building

Notice Date
8/22/2007
 
Notice Type
Modification
 
NAICS
332311 — Prefabricated Metal Building and Component Manufacturing
 
Contracting Office
Department of the Navy, Naval Supply Systems Command, Fleet and Industrial Supply Center Jacksonville, Kings Bay Det, 930 USS Hundley, Bldg 2012 Naval Submarine Base, Kings Bay, GA, 31547, UNITED STATES
 
ZIP Code
00000
 
Solicitation Number
Reference-Number-N4561007RC00028
 
Response Due
8/29/2007
 
Archive Date
9/13/2007
 
Small Business Set-Aside
Total Small Business
 
Description
This is a combined Synopsis/Solicitation for Commercial Items prepared in accordance with the Format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; Proposals are being requested and a written solicitation will not be issued. The Reference Number N4561007RC00028 is issued as a request for Quote (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through the Federal Acquisition Circular 97-19. This solicitation is 100 percent small business set-aside. NAICS 332311. This requirement is for the Navy Consolidated Brig, Charleston, SC 29406. This requirement is for One (1) Safety Storage Inc. Factory Mutual (FM) Approved Model ER0828 Safety Storage Building equipped with the following: Bldg, Bl-Directional, 2-HR Fire Rated, Exp Relief, Nominal Ext. Dimensions 28 Ft. Length by 8 Ft. Width by 9 Ft. High, Includes One (1) Door Sixty Wide by Eighty High on Front Wall; Three (3) Lights, Interior Explosion Proof, with 135 Watt Bulbs, Non-EP Switch, Interior UL-Listed explosion-proof incandescent light fixture with 135w lam (120v, 1.25a. 1-phase), rated for Class I Division 1, Groups C&D, Hazardous Locations, Heavy-duty glass globe with a sealed heavy-duty aluminum housing and equipped with a protective metal guard. Equipped with an exterior UL Listed light switch (sanp type) suitable for outdoor locations; One (1) Door, Sixty Wide by Eighty High on End Wall; One (1) Light, Exterior, Non-Explosion Proof, Fluorescent with 28 Watt Bulb, Exterior UL Listed non-explosion proof light fixture (120V, 1.25, 1-Phase) and one (1) exterior UL Listed photoelectric switch (both suitable for outdoor locations); One (1) Mechanical Ventilator, Low-mount, 600 CFM Fan, Explosion Proof, Consists of a UL Listed totally enclosed explosion-proof motor (60 Hz, 1-Phase) rated for class1, Division 1, Group D. Hazardous Locations housed inside an exterior end wall enclosure. Non-static & non-sparking 12 Inch diameter fan blade to preclude the ignition of hazardows vapors. Exterior exhaust fan housing constructed of heavy gauge steel, with an exterior polyurethane finish for maximum chemical & corrosion resistance. Interior exhaust vent located within 12 Inches of the floor for the extraction of heavier-than-air vapors. Exterior exhaust fan port opening protected with a UL Classified fire damper having a 3-hour fire protection rating. Fire damper has a galvanized steel frame, curtain-type galvanized steel blades, and a UL Listed 165 Degree F fusible link. Exterior exhaust port equipped with shutter assembly. Equipped with an exterior UL Listed fan switch (snap type) suitable for outdoor locations. Automatic system shutdown if fire occurs; One (1) Air Conditioner (Wall mounted, 230/208V 1-Phase), Explosion Proof, 19,000 BTU/HR, UL Listed explosion-proof air conditioner rated for Class 1, Div, 2, Group D. High capacity compressor with internal hermatically sealed overload and solid-state switch to prevent arcing. Hot gas by-pass low ambient control permit operation without freezing up at outdoor ambient temperatures as low as forty-five degree F.; One (1) Heater, Convection Explosion Proof, 240V, 1-Phase, 25,938 BTU/HR, UL Listed explosion-proof Convection Heater (25,938 BTU/HR, 7.6KW, 240V, 31.7A, 1-Phase rated for Class 1, Groups B, C & D, Division 1, Hazardous locations with one (1) interior UL Listed explosion-proof thermostat rated for Class 1, Groups C & D, Division 1 Locations. Thermostat has user adjustable temperature settings from fifty degree F to ninety degree F. The heater?s NEC Operating Temperature Code is T2A, and it is rated for hazardous atmospheres with auto ignition temperatures at or above Five Hundred Thirty Eight Degrees F; One (1) Dry Chemical Fire Suppression system with Remote Annunciation, UL Listed & FM approved pre-engineered system rated for Class A, B and C Fires. Fusible link detection for automatic actuation. Interior nozzle(s) for total flooding application. One (1) exterior UL Listed weatherproof audible alarm (120V, 0, 1A, 1-Phase). Dry Chemical agent storage cylinder (tank) and releasing device housed inside an exterior tamper-proof (key lockable) enclosure per the requirements of NFPA 17 (Standard for Dry Chemical Extinguishing Systems). System equipped with a means for remote annunciation. Automatic ventilation system shutdown (if applicable) upon system actuation; One (1) Load Center (Single Phase) UL Listed, 240/120V, single-phase load center (NEMA 3R) with circuit breaker(s) and main breaker; One (1) Adjustable Register allows for manual regulation of air flow for buildings equipped with heaters, air conditioners or insulation; R11 Insulation, Fire-Rated, Walls, Ceiling & EVPs (if Equipped), Three (3) Exterior Receptacle and Weatherproof (In-Use) Cover, State Seal, South Carolina. STANDARD FEATURES: Factory Mutual System (FM) approved & labeled, Exterior Wall Construction: Weatherproof, bi-directional, 2-hour fire-rated noncombustible construction, per Underwritter Laboratories (UL) Fire resistance Rating Design Number U425, with two (2) layers of UL Classified fire-resistive gypsum wallboard fastened to the interior and exterior sides of steel studs. The interior and exterior surfaces consist of galvannealed steel sheets. Sump Wall Construction: Weatherproof 2-hour fire-rated noncombustible construction, utilizing interior and exterior continuously welded heavy gauge steel sheets for maximum spill containment protection. Roof/Ceiling Construction: Weatherproof 1-hour fire-rated noncombustible construction, utilizing interior galvannealed steel sheets and continuously welded heavy gauge steel roof sheets for maximum durability and weather resistance. Roof/ceiling permanently attached to exterior walls. Explosion relief construction, panel(s) located on back wall. Sixty Inch Wide by Eighty Inch High, Three-hour fire-rated double door(s), UL classified and Labeled, equipped with UL Listed self-closer(s) and UL Listed exterior security lock(s) with keyless interior safety release lever(s), Screened Air Vent(s): air inlet vent(s) equipped with UL Classified and labeled 3-hour rated fire dampers with louvers and screens to provide air flow. Dampers have a galvanized steel frame, curtain-type galvanized steel blades, and a UL Listed 165 Degree F fusible link. Building Base: Open channel construction for forklift and/or crane slings and under building inspections. Internal Spill Containment Capacity: Minimum thirty percent of total storage capacity. Surpasses regulatory and factory mutual requirements for spill containment. Interior Finish: high solids, chemical-resistant epoxy coating with a white aliphatic polyurethane topcoat. Exterior Finish: high solids, chemical-resistant epoxy undercoat with heat reflective white aliphatic polyurethane topcoat. Four(4) hold-down Brackets (structural steel angles) for bolting to purchasers foundation for seismic and wind load anchoring. Static Grounding System: One(1) exterior grounding connection, one(1) 10-foot long 5/8 Inch diameter copper-clad steel grounding rod, one(1) #4AWG copper conductor, and grounding lugs(s). Signage: D.O.T. hazard classification placard with rust-proof aluminum holder and stainless steel clips, and pressure sensitive NFPA 704 Hazard Rating Sign(s). Roof Snow Load: 40 PSF, Wind Load: 110mph, Exposure C, Floor Live Load: 500 psf, Seismic Condition: Zone 4 or Performance Category E. Shipping Charges if applicable. Please quote Brand Name or Equal. If quoting an Equal To product, they must meet or exceed the Governments required specifications. You must submit the specifications with your quote. The following Provisions apply: 52.212-1 Instructions to Offerors-Commercial Items; 52.204-9 Personal Identity Verification of Contractor Personnel (Jan 2006); 52.211-6 Brand Name or Equal, 52.212-3 Offeror Representations and Certifications-Commercial Items; 52.212-4 Contract Terms and Conditions-Commercial Items; 52.212-5 Contract Terms and Conditions Required To Implement Statutes or Executive Orders-Commercial Items, and Citing: 52.204-7, 52.222-26, 52.222-35, 52.222-36, 52.222-37, and 252.204-7004 Central Contractor Registration; 252.212-7001 Contract Terms and Conditions Required To Implement Statutes Applicable to Defense Acquisition Of Commercial items, and Citing:252.225-7001. 252-232-7003 Electronic Submission of Payment Requests-Jan 2004. See Numbered Note 1. Offers are Due by close of business on 29 Sep 2007 and may be faxed to 912-573-2191 or email to nina.miller@navy.mil.
 
Place of Performance
Address: Navy Consolidated Brig, 1050 Remount Road, Bldg 3107, Charleston, SC
Zip Code: 29406
Country: UNITED STATES
 
Record
SN01381707-W 20070824/070822222610 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.