Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF AUGUST 03, 2007 FBO #2076
SOLICITATION NOTICE

C -- Provide Professional Electrical EngineeringConsultant as required to prepareconstruction contract documents.

Notice Date
8/1/2007
 
Notice Type
Solicitation Notice
 
NAICS
541330 — Engineering Services
 
Contracting Office
Attn: Juanita Y. Millsap;Department of Veterans Affairs;Oklahoma City VA Medical Center;921 N.E. 13th Street;Oklahoma City OK 73104
 
ZIP Code
73104
 
Solicitation Number
VA-256-07-RP-0124
 
Response Due
8/16/2007
 
Archive Date
10/15/2007
 
Small Business Set-Aside
Service-Disabled Veteran-Owned
 
Description
THIS IS NOT A REQUEST FOR PROPOSAL (RFP). THIS ANNOUNCEMENT IS SET-ASIDE FOR SERVICE DISABLED VETERAN. DO NOT SEND EMAIL OR FAXES. IT WILL NOT BE ACCEPTED. This VA Medical Center located at 921 NE 13th Street, Oklahoma City OK 73104, is seeking an Electrical Engineering Consultant to provide professional services to include Mechanical, Electrical, Plumbing, Civil, Structural and Engineering Design Services as required to prepare construction contract documents. Engineering firm shall evaluate and upgrade the Normal and Emergency Electrical Distribution Systems at this facility. All line items shall include detailed cost estimates for construction period services in the development of construction contract documents necessary to upgrade the systems, as required, based on the results of the studies are as follows: Line Item 1 - 635-07-200ES (E1) - Provide a study to determine the emergency system loads based on required system branches for the entire Oklahoma City VA Medical Center campus and for all campus generators, excluding Building #5. Any deficiencies observed shall be noted and recommendations provided to correct the deficiencies to bring the building up to current standards. Also provide an evaluation for future growth capacity. Estimated Construction Cost is between 250,000 to 500,000. Line Item 2 - 635-07-201ES (E2) - Provide a study to evaluate and upgrade the secondary distribution system in Substation #2. Any deficiencies observed shall be noted and recommendations provided to correct the deficiencies to bring the building up to current standards. Also provide an evaluation for future growth capacity. Estimated Construction Cost is between $100,000 to $250,000. Line Item 3 - 635-07-202ES (E3) - Provide a study to evaluate and upgrade the entire secondary distribution system in Building 19 and ARF. Any deficiencies observed shall be noted and recommendations provided to correct the deficiencies to bring the building up to current standards. Also provide an evaluation for future growth capacity. Estimated Construction Cost is between $250, 000 to $500,000. Line Item 4 - 635-07-203ES (E4) - Perform lightning protection risks analysis for all building on the entire Oklahoma City VA Medical Center campus. Any deficiencies observed shall be noted and recommendations provided to correct the deficiencies to bring the building up to current standards. Estimated Construction Cost is between $100,000 to $250,000. Line Item 5 - 635-07-204ES (E5) - Perform a study to evaluate and upgrade the emergency electrical distribution system in Bldg. 5 (Boiler Plant). Any deficiencies observed shall be noted and recommendations provided to correct the deficiencies to bring the building up to current standards. Also provide an evaluation for future growth capacity. Estimated Construction Cost is between $100,000 to $250,000. Selection criteria include in descending order of importance as follows: 1. Specialized experience and technical competence of the firm in the type of work required, both prime and consultants, in electrical design and construction of the above project. 2. Professional qualifications of the firm's staff and consultants assigned to the project to include resumes or curriculum vitae and proof of professional registration of key personnel of the electrical engineering firm and consultants, to include subcontractors, the project team (team/office actually accomplishing the work), necessary for satisfactory performance of required services. 3. Geographically located in the State of Oklahoma. 4. Past experience working on VA and/or Government facilities to include hospital setting. 5. Ability of the firm to begin the work within 15 days after award of the contract and capacity to accomplish the work in the required time 6. Demonstrated success in incorporating the use of recovered materials and achieving waste reduction and energy efficiency in the design. 7. Maintaining project schedules, project budgets, and cost control effectiveness. Qualified A/E firm is required to perform 50% of the work and not as a consultant. All interested firms are required to submit three (3) recently completed Standard Form (SF) 330, Architect-Engineer Qualifications, in accordance with Numbered Note 24 to the Contracting Officer shown below no later than 2:00 p.m. (Central Standard Time), Monday, August 13, 2007. Limit SF 330 along with supporting data for a total package of not more than 75 pages, 8-1/2 x 11 paper, 12 pitch. Pages in excess of this maximum limit shall be removed from the proposal and will not be evaluated by the selection board. Relevant projects identified in Part I block 19, shall not be more than 5 years old. Design must meet all applicable and current federal and state codes/requirements, i.e.: NEC, OSHA, EPA, DER, NFPA 101, JCAHO, AHERA, NESHAPS, NFPA, ASTM, PENNDOT, UFAS. The contractor will perform the following tasks: 1. Make site visits as necessary to survey existing conditions as required to determine existing as-built conditions affecting this project. 2. Contractor shall field verify all dimensions, wall layouts, etc. 3. Contractor shall field verify every aspect that relates to the project. 4. Contractor shall coordinate visits with the Project Engineer. 5. Contractor must be proficient in the use of AutoCAD (version 2006) and have access to Microsoft Word 5.0 or higher. NAICS Code 541330 is applicable to this acquisition and the small business size standard is considered $4.5 million. Interested firms are reminded that in accordance with FAR 4.12, prospective contractors shall complete electronic annual representations and certifications in conjunction with FAR 4.11 required registration in the Central Contractor Registration (CCR) database prior to award of a contract. Point of contact is Juanita Millsap (405) 270-0501 ext 6118 or Demarcus Thompson (405) 270-0501 ext 6122, at the Oklahoma City VA Medical Center, 921 N.E. 13th Street, Oklahoma City, OK 73104. Questions concerning this project may be directed to Andy Garcia, General Engineer at (405)270-0501 ext. 3513. Solicitation number VA-256-07-RP-0124 has been assigned to this project and should be referenced on all correspondence regarding this announcement.
 
Place of Performance
Address: Department of Veterans Affairs Medical Center;921 N.E. 13th Street;Oklahoma City, OK 73104
Zip Code: 73104
Country: USA
 
Record
SN01358708-W 20070803/070801220929 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.