66 -- BIOSTAT B-DCU TWIN

Notice Date
9/6/2007
 
Notice Type
Solicitation Notice
 
NAICS
334516 — Analytical Laboratory Instrument Manufacturing
 
Contracting Office
Department of Health and Human Services, National Institutes of Health, Nat'l Institute of Diabetes, Digestive, & Kidney Diseases, 2 Democracy Plaza, Suite 700W 6707 Democracy Blvd., MSC 5455, Bethesda, MD, 20892-5455, UNITED STATES
 
ZIP Code
00000
 
Solicitation Number
NIH-NIDDK-07-351
 
Response Due
9/18/2007
 
Archive Date
10/3/2007
 
Description
This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR 12.6 as supplemented with additional information included in this notice. This announcement constitutes the only solicitation and a separate written solicitation will not be issued. This solicitation number is NIH-NIDDK-07-351 and is issued as a Request for Quotation (RFQ). The solicitation/contract will include all applicable provisions and clauses in effect through Federal Acquisition Circular 2005-18. The North American Industrial Classification (NAICS) code 334516 with a size standard of 500. The National Institutes of Health (NIH), National Institute of Digestive, Diabetes & Kidney Diseases (NIDDK) intends to procure the following items: Brand Name or Equal for the following Sartorius products: Catalog # Qty Item, description BIOSTAT? B-DCU (PER TWIN UNIT) 8847002 1 DCU Tower Bench top housing with DCU-Controller - Stainless steel housing, dimensions (W x H x D) 300 x 830 x 550 mm - Rear panel with SubD connectors for connection of I/O cables Built in DCU system - VME-Rack with DC power supply - VME-bus CPU board * 32-bit Microprocessor 68040, main memory 8 MB DRAM * PCMCIA card 16 MB with software and configuration * PCMCIA card, 256 KB for user parameters battery buffered - Touch screen operator panel * Industrial hardened 486DX PC, installed in flat enclosure * Active 10.4 inch color graphic display * Resistive touch screen and dedicated function keys - Measurement cassette * for installation of up to 12 DCU amplifiers - 2 serial interfaces RS232 for each supply tower * in connection with balance driver to the connection of exernal balances - set of cables for process connection Power supply 120V AC or 230 V AC 8847185 1 Sensor Plates DCU-Tower, Twin - for all electrode cables 8842663 7 Motherboard M30 - idle board - for up to two DCU amplifier 8843252 1 Card Rack Extension - for more than 12 amplifiers or more than 6 motherboards M30 8842671 2 Temperature amplifier DCU-3 - for connection of a Pt 100 temperature sensor - 3 wire connection - measuring range: 0 - 150 ?C 8842680 2 pH amplifier DCU-3 - for connection of an pH-probe - galvanic isolated input - measuring range: 2 - 12 pH 8842698 2 pO2 amplifier DCU-3 - for connection of a polarographic pO2-probe - galvanic isolated input - measuring range: 0 - 100% sat 8842701 2 Foam amplifier DCU-3 - for connection of a conductive foam probe - adjustable sensitivity - limit switch with digital output signal 8842736 2 Level amplifier DCU-3 - for connection to a conductive level probe - limit switch with digital output signal 8842744 2 Redox amplifier DCU-3 - for connection of an Redox probe - galvanic isolated input - measuring range: - 1000 to +1000mV 8846618 2 FUNDALUX? II amplifier DCU - for connection 0f FUNDALUX? II probe - measurement range 0 - 6 UA (Absorbance Units) - incl. installation kit - additionaly Project specific configuration DCU-3 (8842841) for the DCU-Systems are necessary 8842795 1 Extension board serial interfaces DCU-2/3 - VME bus board - 6 serial interfaces 8842906 1 Installation kit for 6 serial interfaces DCU-3 - for installation in bench top housing or tower - for 6 serial interfaces - rear panel with connection cable 8842841 2 Project specific configurations for DCU-3 1 x PCMCIA-Card programmed with current software version and project specific configuration - Indication of all process values via graphic display - Alarm monitoring for process values and digital inputs - Digital calibration for sensors and pump totatizer - Up to 48 digital controller loops * PID controller * 4 stage PID cascade controller * Set point controller * Timer - Up to 64 sequences - Interlocks - Set point profiles for control loops - Four recipes for operator parameters - Password protection for all system critical parameters - Manual override of all process inputs and outputs - User selectable recorder outputs - Printer connection via serial interface RS232 - Communication with supervisory computer via serial interface RS422 ASCII-Protocol 1 x PCMCIA-Card programmed for microbial culture applications where the Additive Flow module can be configured to either keep the total flow or the ratio of e.g. Air and O2 constant through the use of MFCs for Air and O2. 8842655 1 Balance driver DCU-3 - Software module for the connection of a balance via - for Sartorius or Mettler balance with RS232 interface - detailed specification of balance type needed 8843476 2 Balance system 7 kg for DCU / ?DCU - weight indication via fermentor control system - max. load 7 kg - readability 0.1 g - stainless steel platform - platform dimensions diam. 233 mm - incl. connection cable 8843163 2 Connection cable for Sartorius balance /S - for connection of a Sartorius balance to DCU-System - for balances with RS232 interface - cable length: 2 m Gas-Mod Gassing module 2 Custom Gassing module based on Additive Flow for MO and CC use Stainless steel module for integration in Supply Tower For gas mixtures of Air, N2 (will not be used), O2, CO2 with sparger and overlay aeration For simultaneous control of dissolved oxygen (using Air and O2) as well as pH control using CO2. For use with additional GFRC software configuration where the Additive Flow module can be configured to either keep the total flow or the ratio of e.g. Air and O2 constant through the use of MFCs for Air and O2. Consists of: - four independent gas flowpaths with Sparger Outlet - one independent flowpath with Overlay Outlet - manual toggle switch for headspace or sparger flowpath for Air and CO2 - 4 x pressure controller and manometer - massflow controllers for Air and O2 dosing - 2 x pressure relief valves - 5 x check valves 8847541 10 Rotameter 1.3 - 13 l/min, Scale 65 mm For installation in Gassing module and visual indication for each gas - Plug-in module - precision control valve - metering tube - For Air/CO2 Overlay, Air, O2, CO2, N2 (will not be used) 5 rotameters per vessel 8847789 2 Massflow controller Air 10 lpm (1 per vessel) For installation in Gassing module - calibrated for air or O2 - thermal mass flow controller - controlled by DCU controller - measuring / control range: Mass flow Controller measuring / control range Massflow Controller 1 Lpm 0.02 1.0 Lpm Massflow Controller 3 Lpm 0.10 3.0 Lpm Massflow Controller 10 Lpm 0.20 - 10 Lpm Massflow Controller 20 Lpm 0.40 -20 Lpm 8848475 2 Massflow Controller O2 10 lpm (1 per vessel) For installation in Gassing module - calibrated for air or O2 - thermal mass flow controller - controlled by DCU controller - measuring / control range: Mass flow Controller measuring / control range Massflow Controller 1 Lpm 0.02 1.0 Lpm Massflow Controller 3 Lpm 0.10 3.0 Lpm Massflow Controller 10 Lpm 0.20 - 10 Lpm Massflow Controller 20 Lpm 0.40 -20 Lpm 8847053 2 Pump module 3 x WM 102 plus 1 x WM 313 Stainless steel module for integration in Supply Tower - 3 x integrated peristaltic pumps WM 102 for * base * feed 1 * feed 2 - 1 x integrated peristaltic pump WM 313 for * harvest - man/auto/off switch - digitally controlled by DCU controller - delivery rate depends on tube diameter * with inside diameter of 3.2 mm WM 102; max. 17 mL/min WM 313; max. 112 mL/min 8847037 2 Temperature module for double wall culture vessel, 115 VAC Stainless steel module for integration in Supply Tower For double wall culture vessel Consist of: - thermostat system with circulation pump *working temperature from 8?C above the cooling water temperature up to 60?C - electric heating 1000 W - pulsed cooling water valve - temperature measurement double wall - front connections (quick connectors): * double wall culture vessel * exhaust cooler - rear connections: * connection kits (water, gases, voltage supply) 8847843 2 Electric Module, 120 VAC Stainless steel module for integration in Supply Tower Consists of: - servo drive motor controller07 -Process I/O board for DCU Tower VME-bus Process Interface board FIB-3 * 32 analog inputs, 0-10V; 0/4-20mA * 8 analog outputs, 0-10V; 0/4-20mA with option power output FIB-3 - DFC-4 (8848220) * 8 digital inputs, 24VDC * 16 digital outputs, 24VDC * 2 serial interfaces, RS 232/ RS 422 - connection cable Supply Tower - DCU Tower 8847169 2 Stirrer drive 400 W maintenance-free AC servo motor 400 W - stirrer speed range * UniVessel? 5L: 20 - 1500 rpm * UniVessel? 10L: 20 - 1200 rpm 8847266 2 UniVessel? 5L, double wall Total volume 6.6 L Working volume 0.4 - 5 L Consist of: - double wall, round bottom glass vessel - polished top plate with handles - stainless steel stand for culture vessel - Pt 100 temperature probe for 6 mm port - harvest pipe (height-adjustable) - 4-way addition port for 19 mm port - blind plugs for all 6/12/19 mm ports - spare O-ring set - standard tool kit Material - product side * borosilicate glass * stainless steel 1.4435 * EPDM / FDA - others * stainless steel 1.4301 8847320 2 Standard coupling Coupling between stirrer shaft - motor - rubber sleeve for direct connection 8847355 2 Stirrer shaft UniVessel? 5 L, SMS Stirrer shaft with single mechanical seal Material: * silicon carbide / carbon - product side * stainless steel 1.4435 - others * stainless steel 1.4301 8847371 4 6-blade disc impeller UniVessel? 5L - stainless steel AISI 316 L - impeller diameter: UniVessel? Impeller diameter 1 L 45 mm 2 L 53 mm 5 L 64 mm 10 L 75 mm 8847401 2 3-blade segment impeller UniVessel? 5L 8846820 2 Baffle UniVessel? 5L For installation in 6 mm top plate port - 4 baffles (10L UniVessel?: 1 baffle) - stainless steel AISI 316 L RingSp Ring sparger, UniVessel? For installation in 6 mm top plate port - aeration tube with sparger ring - hose connector for tubing, Di = 3.2 mm - stainless steel AISI 316 L - Ring sparger UniVessel? 5L with 1 welded baffle 8846855 2 Ring sparger UniVessel? 5L 8846880 2 Exhaust cooler UniVessel? 5 L/10 L For installation in 19 mm top plate port - stainless steel 1.4435 - silicone tubing's with quick connectors - required autoclave height * UniVessel? 5L with exhaust cooler 700 mm * UniVessel? 10L with exhaust cooler 820 mm 8810079 4 Air inlet/ Exhaust filter, Midisart? 2000 For culture vessels and storage bottles - PTFE-filter in PP housing - pore size 0.2 ?m - filter area 20 cm? - flow rate at 0.1 bar 5l/min - at least 20 times autoclavable at 121?C - hoses for tubing on both sides from di = 3.2 mm and up 8807809 2 Universal adapter 3.2 mm For installation in 6 mm top plate port - hose connector for tubing, Di = 3.2 mm - stainless steel 1.4435 8844631 2 Inoculation port 6 mm For installation in 6 mm top plate port - stainless steel 1.4435 8840610 2 1-channel inoculation kit (M 26x1) For inoculation port 19 mm - cannula 6 x 0.5 mm - sterile sleeve - for silicone tubing 3.2 x 1.6 mm - stainless steel 1.4435 8844623 2 Manual sampler Autoclavable, allow a simple and sterile sampling Consist of: - sampling tube, volume 15 ml - syringe - sterile filter - holder for installation at culture vessel - 1 m silicone tubing 1.6 x 1.6 mm - 1x tubing clamp 8823600 6 Storage bottle 250 ml 8847436 2 Bottle support UniVessel? 5L - removable bottle supprt - for up to three 500 ml storage bottles - stainless steel 1.4301 2.6. Probes 5L 8837243 2 pH electrode-EF-Set 12/325/2 K8-HM-UniVessel? 5/10L Internally pressurized gel electrode (Hamilton) - for 12 mm top plate port - electrode length 325 mm - connection cable 200 cm - K8 - buffer solution pH 4, 250 ml bottle - buffer solution pH 7, 250 ml bottle - buffer solution pH 10, 250 ml bottle 8837233 2 pO2 electrode-Set-12/325/2-L-HM-UniVessel? 5L/10L polarographic electrode (Hamilton) - for 12 mm top plate port - electrode length 325 mm - connection cable 200 cm - 1 additional membrane body - 50 ml electrolyte solution 8844461 2 Foam sensor, complete For 6 mm top plate port - probe length 80 mm - ceramic insulation - fitting - connecting cable 100 cm 8844488 2 Level sensor 1L/2L/5L, complete For 6 mm top plate port - probe length 150 mm - ceramic insulation - fitting - connecting cable 100 cm 8844194 2 Redox-electrode 5/10L, complete For a 19 mm port - internally pressurizes gel electrode (Mettler-Toledo) - probe length 325 mm - fitting - connection cable 2 m - Redox buffer solution, 250 ml 8846602 2 FUNDALUX? II UniVessel 5/10L, OPL 10mm - turbidity sensor - for 19 mm top plate port - insertion length 320 mm - measurement gap 10 mm for microbial culture - 2 x O-ring (FDA approved) EPDM - connection cable 2 m INSTALLATION Installation / Start-Up. Biostat BDCU installation and start-up. The ?equal? items must meet the characteristics of the brand name item to be acceptable for award. Basis for Award: Offerors must provide descriptive literature or other material that demonstrates their offer meets the forgoing requirements. The contract will be awarded to the responsible offeror whose offer fully meets the requirements of the solicitation, provides the best value, with price and technical factors equally important in award evaluation. The offeror must include a completed copy of the following provisions: NOTE: Vendors must submit a listing of the most recent contracts/awards (minimum of 3) in which similar apparatus or equipment was purchased. Contracts/awards may include those entered within the Federal Government, state and local governments and commercial concerns. Include the following information for each contract or subcontract: 1. Name of Contracting Organization, 2. Contract Number (for subcontracts provide the prime contract number and the subcontract number, 3. Contract Type, 4. Total Contract Value, 5. Description of Requirement to include Statement of Work, 6. Contracting Officer?s Name and Telephone Number, and 7. Program Manager?s Name and Telephone Number. If past performance questionnaire is available, please submit. 1) FAR Clause 52.212-1 Instructions to Offerors ? Commercial; 2) FAR Clause 52.212-2, Evaluation ? Commercial Items. As stated in FAR Clause 52.212-2 (a), ?The Government will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to the solicitation will be most advantageous to the Government, price and other factors considered.? The following factors shall be used to evaluate offers: Technical Evaluation, Price, and Past Performance; 3) FAR Clause 52.212-3, Offeror Representations and Certifications ? Commercial Items; 4) FAR Clause 52.212-4, Contract Terms and Conditions Required To Implement Statues or Executive Orders ? Commercial Items, Contract Terms and Conditions ? Commercial Items; and 5) FAR Clause 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders ? Commercial Items ? Deviation for Simplified Acquisitions. Interested vendors capable of providing the Government with the products specified in this synopsis should submit their quotation to the below address. The offeror must include in their quotation, the unit price, the list price, shipping and handling costs, the delivery period after contract award, the prompt payment discount terms, the F.O.B. Point (Destination or Origin), the Dun & Bradstreet Number (DUNS), the Taxpayer Identification Number (TIN), and the certification of business size. The clauses are available in full text at http://www.arnet.gov/far. Two (2) copies of quotations will be due thirteen (13) calendar days from the publication date of this synopsis on September 18, 2007 at 3:00p.m. EST. The quotation must reference ?Solicitation number? NIH-NIDDK-07-351. All responsible sources may submit a quotation, which if timely received, shall be considered by the agency. Quotations must be submitted in writing to the National Institute of Diabetes and Digestive and Kidney Diseases 6707 Democracy Blvd., Room 765C, Bethesda, Maryland 20817, Attention: Tina Robinson. Faxed copies will not be accepted. PLEASE NOTE: In order to receive an award from the NIDDK, contractors must be registered in the Central Contractor Registration (CCR) www.ccr.gov.
 
Record
SN01396767-W 20070908/070906220602 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.