SOLICITATION NOTICE
J -- Switchgear Testing Service
- Notice Date
- 9/19/2007
- Notice Type
- Solicitation Notice
- NAICS
- 238210
— Electrical Contractors
- Contracting Office
- Department of Veterans Affairs;James J. Peters VA Medical Center;130 West Kingsbridge Road;Bronx NY 10468-3904
- ZIP Code
- 10468-3992
- Solicitation Number
- VA-243-07-RQ-9002
- Response Due
- 9/24/2007
- Archive Date
- 11/23/2007
- Point of Contact
- Mehmet Bagriyanik Contract Specialist 718.741.4323
- E-Mail Address
-
Contracting Officer
(Mehmet.Bagriyanik@va.gov)
- Small Business Set-Aside
- Service-Disabled Veteran-Owned
- Description
- The Scope of Work Item # 1: This project will include but is not limited to providing all materials, tools test equipment, manpower and supervision to perform routine maintenance and testing per NETA Standards, on the 480 Volt circuit breakers located in the switchgears in networks 1 & 2. Item # 2: Service secondary injector test and re-calibrate (65) sixty five low voltage air circuit breakers during 13 early morning two hour service windows. Because of patient safety issues, there is no guarantee that the 13 service windows will be consecutive. In the event of an emergency or scheduling conflict a scheduled shutdown service window may be postponed or cancelled at no additional cost to the government. At the completion of the work / project the contractor will provide a detailed written report for each breaker with the test results and corrective actions. Item # 3: For the duration of the project, through the completion of all work, the contractor will provide a 24 hour emergency phone number and will be required to respond to an emergency within 4 hours. At the completion of all work the contractor will provide a 90 day warranty period, at no additional cost to the government with a 24 hour emergency phone number and will be required to respond to an emergency within 4 hours. Item # 4: This work will require opening each breaker (ONE AT A TIME) racking out the cubical rails, service, secondary injection test, rack back in and returned to service. This scope does not require the bus to be de-energized. Item # 5: Service and test (4) network / service protectors and network transformers. The network transformers will be required to be de-energized to be serviced. NOTE: THIS NOTICE WAS NOT POSTED TO FEDBIZOPPS ON THE DATE INDICATED IN THE NOTICE ITSELF (19-SEP-2007); HOWEVER, IT DID APPEAR IN THE FEDBIZOPPS FTP FEED ON THIS DATE. PLEASE CONTACT fbo.support@gsa.gov REGARDING THIS ISSUE.
- Web Link
-
Link to FedBizOpps document.
(http://www.fbo.gov/spg/VA/BroVANAP/VAMD/VA-243-07-RQ-9002/listing.html)
- Place of Performance
- Address: James J Peters Medical Center;130 West Kingsbridge Road;Bronx, NY
- Zip Code: 10468-3904
- Country: US
- Zip Code: 10468-3904
- Record
- SN01411436-F 20070921/070920091917 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |