Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF SEPTEMBER 01, 2007 FBO #2105
SOLICITATION NOTICE

13 -- Propulsion Base Assembly for M98/M99 Grenade

Notice Date
8/30/2007
 
Notice Type
Solicitation Notice
 
Contracting Office
RDECOM Acquisition Center - Pine Bluff, ATTN: AMSSB-ACP, 10020 Kabrich Circle, Pine Bluff, AR 71602-9500
 
ZIP Code
71602-9500
 
Solicitation Number
W911RP-07-R-0035
 
Response Due
10/15/2007
 
Archive Date
12/14/2007
 
Small Business Set-Aside
N/A
 
Description
Propulsion Base Assembly 35,825 each for theM98/M99 Grenade. The following drawings and specifications are applicable: 13-19-730, 13-19-114 Rev J, 13-19-115, Rev J, 13-19-819 Rev A, 13-19-159 Rev E, 13-19-729, 13-19-955, ASME Y14.100, ASME Y14.5, EA -DTL-2197 Rev A, NOR 256-0036-011, EA-DTL-2198 Rev A, NOR 256-0038-008, ASME B18.6.3, ASTM A240 Rev C, MIL-STD-171 Rev E, ASTM 2404 Rev E, AMS 2405 Rev C, AMS 2433 Rev C, ASTM B36, ASTM B121, L-P-410, EA-G-1338, ASTM D4066 Rev A. The type of contract shal l be firm fixed price. Solicitation shall contain an option to purchase up to 100% of the initial quantity. The First Article Test (FAT) quantity shall consist of 289 Propulsion Base Assemblies. The FAT shall be governed by the requirements located in D A-DTL-2197 & EA-DTL-2198. When addressing the special requirements that the Propulsion Bases should meet, please refer to para 4.3.4(e) in the DTL's. Each individual component that makes up the Propulsion Base Assembly will be subjected to the FAT, with a sample size of 10 each. Individual components are defined as those Propulsion Base Assembly components that are controlled by their own drawing. These components must be measured and reported upon individually, to be included in the overall FAT report . The contractor is required to perform all required measurements for all components and assemblies and submit a FAT report detailing all of those measured inspections. Every requirement of every drawing and specification must be measured and reported. All FAT sample units will be individually marked for identification purposes, and the accompanying FAT report will list each unit along with all required drawing and/or specification requirements. The FAR report along with the identified FA units will be p resented to the Government for verification purposes at the time of the FAT. The government intends to visit the contractors facility to witness first-article testing. FOB Destination, Pine Bluff Arsenal, AR. Acquisition is being conducted utilizing f ull and open competition. All responsible sources may submit a proposal which shall be considered by the agency. The solicitation document contains information that has been designated as Militarily Critical Technical Data. Only businesses that have been certified by the Department of Defense, United States/Canada Joint Certification Office, and have a valid requirement may have a copy of the solicitation documents. All requests for copies of the solicitation document must include a certified copy of DD Fo rm 2345, Militarily Critical Technical Data Agreement. To obtain certification, contact: Commander, Defense Logistics Information Service (DLIS), ATTN: U.S./Canada Joint Certification Office, 74 Washington Avenue North, Battle Creek, MI 49017-3084 or call the DLIS at (800)-352-3572. The DLIS Unites States/Canada Joint Certification Lookup service is available via the Internet at: http://www.dlis.dla.mil/jcp/. Solicitation will issue on or after 13 Sep 2007 with a closing date on or after 15 October 2007. Requests for the solicitation package must be in writing, via facsimile to 870/540-3730 or via e-mail to pam.burton@us.army.mil . Ensure solicitation number W911RP-07-R-0035 is listed in the subject line on all solicitation requests and provide required D D 2345. Additionally, companies full mailing address, telephone and fax numbers, and email addresses where available should be listed on all requests. Email request that do not contain the solicitation number in the subject line will be deleted without review. Electronic Proposals are not acceptable; proposals shall be mailed to arrive by the time specified in the solicitation to the address specified in the solicitation. Offerors shall submit all technical questions regarding this solicitation to the Contracting Officer, in writing, no later than 15 days after issuance of this Request for Proposal. Questions may be sent via facsimile or email, again the so licitation number MUST BE referenced in the subject line on any correspondence. Verbal questions will not be addressed. Point of contact is Pamela J. Burton, Contract Specialist, 870-540-4074.
 
Place of Performance
Address: RDECOM Acquisition Center - Pine Bluff ATTN: AMSSB-ACP, 10020 Kabrich Circle Pine Bluff AR
Zip Code: 71602-9500
Country: US
 
Record
SN01390911-W 20070901/070830222206 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.