Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF DECEMBER 02, 2007 FBO #2197
SOLICITATION NOTICE

H -- Sprinkler, fire alarm, hydrant servicesFire prevention services FY 08OM

Notice Date
11/30/2007
 
Notice Type
Solicitation Notice
 
NAICS
561790 — Other Services to Buildings and Dwellings
 
Contracting Office
Department of Veterans Affairs;VAMC Northampton;Acquisitions-001A;421 North Main Street;Leeds MA 01053-9764
 
ZIP Code
01053-9764
 
Solicitation Number
VA-241-08-RQ-0067
 
Response Due
12/10/2007
 
Archive Date
2/8/2008
 
Point of Contact
Jane LaBorde Contract Specialist 413-584-4040 ext. 2404
 
E-Mail Address
Email your questions to VA Contracting Officer
(Jane.Laborde@va.gov)
 
Small Business Set-Aside
Total Small Business
 
Description
VA 241 08 RQ 0067 VAMC NORTHAMPTON PROVIDE LME TO INSPECT, TEST, PER NFPA 25 AND CONDUCT MAINTENANCE OF UNDERGROUND PRIVATE SERVICE WATER MAINS, HYDRANTS,UNDERGROUND VALVES AND POST INDICATOR VALVES PER REQUIREMENTS OF NFPA 25. CONDUCT ANNUAL WATER FLOW TESTS OF UNDERGROUND PIPING FROM HYDRANTS AT 24 HYDRANT LOCATIONS AND DOCUMENT TEST RESULTS. ALL TESTS AND INSPECTIONS INCLUDE REQUIRED TEST RESULT REPORTS TO BE FURNISHED TO VAMC LEEDS, MA (AL NELSON). PROVIDE ANNUAL INSPECTION OF APPROXIMATELY 300 PROTABLE ABC FIRE EXTINGUISHERS PER NFPA 10 LOCATED THRU OUT VAMC LEEDS, AND CHERRY ST.,NORTHAMPTON PROPERTY. INSPECTIONS NORMALLY PERFORMED IN AUGUST. VENDOR TO BILL SEMI-ANNUAL. TESTS TO BE CONDUCTED PER JCAHO 5.40, NFPA 25 AND LIFE SAFETY CODE 101. PRICING DOES NOT INCLUDE RETESTS, FAILURES, OR REPAIRS. TO BE NORMALLY PERFORMED IN FEB AND AUG. PROVIDE LME FOR ALL ANNUAL TESTING PER NFPA #72. ALL ELECTRICAL FIRE ALARM DEVICES, NODE PANELS, FIBER OPTIC, BATTERY LOAD TEST, NAC SIGNALING, HORN STROBE, TAMPERS, SUPERVISORY AND DUCT SIGNALLING DEVICES PER JCAHO 5.40, NFPA 72, AND LIFE SAFETY CODE 101. PRICE INCLUDES 24/7 LABOR ON SERVICE CALLS AND $500.00 DEDUCTIBLE PER CONNECTED FIRE ALARM DEVICE FAILURE. PRICE INCLUDES TESTING AND INSPECTIONS OF CHERRY STREET NORTHAMPTON. ANNUAL INSPECTIONS ARE DIVIDED INTO QUARTERS, DECEMBER, MARCH AND JUNE,SEPTEMBER. ALL TESTING AND INSPECTION REPORTS REQUIRED PROMPTLY UPON TESTING AND INSPECTIONS. DEFICIENCIES WILL BE REPAIRED IMMEDIATELY BY VENDOR. PROVIDE LME FOR ALL SEMI-ANNUAL TESTING PER NFPA 25 ON CHERRY ST Northampton MA. WET AUTOMATIC FIRE ALARM SPRINKLER SYSTEMS, FLOW SWITCHES, TIME FLOW TO ALARM TESTS, PIV FULL STROKE EXERCISES, OSY FULL STROKE EXCERCISE, MAIN DRAIN TEST AND EXCERCISE, RESIDUAL/STATIC PSI READINGS, AND ALL DOCUMENTAION OF TESTS AND REPORTS. TESTS TO BE CONDUCTED PER JCAHO 5.40, NFPA 25 AND LIFE SAFETY CODE 101. PRICING DOES NOT INCLUDE RETESTS, FAILURES, OR REPAIRS. ALL NFPA 25 TESTS TO BE NORMALLY PERFORMED IN DEC AND JUNE. ANNUAL FLOW TEST OF 24 FIRE HYDRANTS AND DOCUMENTATION PER NFPA 25. TESTING AND INSPECTING OF 3 DOMESTIC WATER PUMPS LOCATED IN BOILER PLANT AND DOCUMENTED PUMP CURVE TEST REPORT ON RESULTS PER NFPA 25, 2002 EDITION, SECTION 8.3.3.2 AND 4.3. Set a Side for Small Businesses. This may or may not be an all or nothing award. CALL THE CONTRACTING OFFICER AT 413 584-4040 X2404 or email Jane.Laborde@va.gov for solicitation.
 
Place of Performance
Address: VAMC;421 N Main st & Cherry St;Leeds
Zip Code: 01053
Country: USA
 
Record
SN01461106-W 20071202/071201074234 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.