Loren Data's SAM Daily™

fbodaily.com
Home Today's SAM Search Archives Numbered Notes CBD Archives Subscribe
FBO DAILY ISSUE OF FEBRUARY 14, 2008 FBO #2271
SOLICITATION NOTICE

Z -- ASBESTOS ABATEMENT

Notice Date
2/12/2008
 
Notice Type
Solicitation Notice
 
NAICS
238990 — All Other Specialty Trade Contractors
 
Contracting Office
General Services Administration, Public Buildings Service (PBS), Charleston Field Office (3PKFC), 300 Virginia Street, East Room 1620, Charleston, WV, 25301, UNITED STATES
 
ZIP Code
00000
 
Solicitation Number
GS-03P-08-QN-C-0084
 
Response Due
2/27/2008
 
Archive Date
3/13/2008
 
Point of Contact
Katie Morris, Procurement Technician, Phone 304-347-5155, Fax 304-347-7079, - Katie Morris, Procurement Technician, Phone 304-347-5155, Fax 304-347-7079
 
E-Mail Address
katie.morris@gsa.gov, katie.morris@gsa.gov
 
Small Business Set-Aside
Total Small Business
 
Description
At the Wheeling Federal Building, 1125 Chapline Street, Wheeling, WV 26003, the contractor shall provide all labor, supervision, materials and equipment to perform all work required to abate asbestos from the following locations. All asbestos notated on the attached Asbestos Building Assessment date 7/25/90. Pages of this assessment to be included are pages 8-34, page 36, pages 41-48, page 59, and page 67. All assessment category codes are number 6(ACBM with potential for damage) except for page 16 which is code number 8 (No ACBM or suspect ACBM detected). The ceiling system referenced on page 16 will never the less be removed in its entirety as a part of this contract. All areas where asbestos pipe insulation is removed will be reinsulated with fiberglass insulation of equal thickness. The fiberglass will be factory covered with reinforced paper so as no fiberglass is exposed. Any fiberglass not covered due to installation parameters will be caulked in the field. All bends and joint fittings shall have a plastic shield over the insulation. Insulation proposals must be submitted and approved by the CO prior to any abatement work beginning. The floor referenced on page 17 will be cleared of carpet, floro tile and mastic, prepared for and coated with clear water based epoxy as a part os this project. The floors reference don pages 48 and 59 will be cleared of floor tile and mastic, prepared for and coated with clear water based epoxy as a part of this project. Also included in the project will be the abatement of lead based paint which is above the drop ceiling mentioned above and referenced on page 16. This ceiling shall be painted with a flat white latex after abatement as a part of this project.
 
Place of Performance
Address: Wheeling Federal Building, 1125 Chapline Street, Wheeling, WV
Zip Code: 26003
Country: UNITED STATES
 
Record
SN01507156-W 20080214/080212225224 (fbodaily.com)
 
Source
FedBizOpps Link to This Notice
(may not be valid after Archive Date)

FSG Index  |  This Issue's Index  |  Today's FBO Daily Index Page |
ECGrid: EDI VAN Interconnect ECGridOS: EDI Web Services Interconnect API Government Data Publications CBDDisk Subscribers
 Privacy Policy  Jenny in Wanderland!  © 1994-2024, Loren Data Corp.