SOLICITATION NOTICE
65 -- Medical Equipment
- Notice Date
- 3/6/2008
- Notice Type
- Solicitation Notice
- NAICS
- 339112
— Surgical and Medical Instrument Manufacturing
- Contracting Office
- Department of Veterans Affairs;North Texas Veterans Health Care Center;4500 S. Lancaster Road;Dallas TX 75216
- ZIP Code
- 75216
- Solicitation Number
- VA-257-08-RQ-0114
- Response Due
- 3/12/2008
- Archive Date
- 4/11/2008
- Point of Contact
- Rita Anderson Contract Specialist 214-857-0043
- E-Mail Address
-
Email your questions to Contract Specialist
(rita.anderson@va.gov)
- Small Business Set-Aside
- Service-Disabled Veteran-Owned
- Description
- This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; no proposals are being requested and a written solicitation will not be issued. The solicitation number is VA257-08-RQ-0114. This acquisition is issued as a Request for Quote (RFQ). The solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 2005-24. The North American Industry Classification System Code (NAICS) for this procurement is 339112. This requirement is 100% SDVOSB Set-Aside. VA North Healthcare System, Dallas, Texas, has a requirement for the following: CLIN 0001: 1 EACH, TOTAL CLIN $__________. UP Encore Surgical Pack OR 120V SURGICAL Laser used for cutting, ablating and coagulating tissues with minimum or no charring of tissue. The laser shall have a wavelength of 10.6 microns. Pulsed laser capable of delivering a pulse width of 1 millisecond or less. Pulse energies must be capable of reaching 250 millJoules per pulse. Individual Pulse Control - the energy of each pulse should be controlled by the user in a range of 2-250 milliJoules. User Interface - the laser system should have an integrated, color LCD, touch-screen control panel. Energy source - The laser must be a sealed carbon dioxide tube. It must be RF (radio frequency) excited. Energy Output - the laser shall be capable of generating up to 60 Watts of average power in the pulse mode and 60 watts in continuous wave mode. Spot Size - the laser and system accessories must permit spot sizes of 0.16 mm to 2.5 mm at the thermal ablation threshold. Speed of Cutting Adjustment - the user must be able to adjust the repetition rte of pulse delivery from 1 to 1000 pulses per second (Hz) Time Exposure Control- the laser exposure time can be fixed and shall be selectable in a range of 1 millisecond to 1 second. Red aiming beam - the laser shall have a red aiming beam with a continuously adjustable intensity up to 5.0 milliwatts and a circular beam profile. Long Reach Surgical Arm - the unit shall have a delivery system capable of reaching over and into sterile surgical field by having a vertical height of at least 77 inches and a horizontal reach of 6 feet. Computer Pattern Generator for Rapid, large Area Resurfacing - the laser shall have an accessory for resurfacing which provides energy in a collimated bam and telecentric pattern. The laser must allow the scanning system to operate at repetition rates up to 600 pulses per second and complete a single pattern scan of 1.4 cc x 1.4 cm in 0.18 sec. Scanner must communicate directly with laser control electronics. Scanner and laser system must be powered by the same power supply. Laser electronic must monitor galvo position in a point-by-point real-time fashion. CLIN 0002: 1 EACH, DIGITAL ACUBLADE KIT FOR UPST, NO ACUSPOT, NEW GA, TOTAL CLIN $__________. CLIN 0003: 4 EACH, POWERSUITE GOGGLES, SAFETY, (0638-430-01). UNIT PRICE: $__________, TOTAL CLIN $__________. CL IN 0004: 1 EACH OPERATOR MANUAL UNIT PRICE: $__________, TOTAL CLIN $__________. CLIN 0005: TRAINING FEE UNIT PRICE: $____________, TOTAL CLIN $__________. Delivery must be made to the address listed below No Later Than 30 April 2008. THIS SOLICITATION MUST BE QUOTED ALL OR NONE. SUBSTITUTE ITEMS: If you plan to provide similar like items to those cited in the purchase description, provide in your response the similar like item name and the catalog or part number you intend to furnish and the characteristics of the substitute item that are equivalent to the item named in the purchase description. You will be asked to provide documents, which clearly describe the items so that they can be evaluated by the end user. Items otherwise equal may not satisfy the requirement due to differences in material composition, size, environmental application, etc. Final award will be based on lowest price technically acceptable. If an item is furnished, which does not meet the requirement the item will be returned at the vendor's expense for a full refund. (End of Provision) To be delivered to VA NORTH HEALTH SYSTEM, 4500 S. Lancaster Road, Bldg. 44, Dallas, Texas 75216. The provisions at FAR 52.212-1, Instructions to Offerors-Commercial, apply to this acquisition. A completed copy of the provisions at FAR 52.212-3, Offeror Representations and Certifications-Commercial Items must be included with the offer. FAR 52.212-4, Contract Terms and Conditions-Commercial Items, applies to this acquisition. FAR 52.212- 5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Items; 52.225-3, Buy American Act Free Trade Agreements Israeli Trade Act (Jan 2005) (41 U.S.C. 3301 note, 19 U.S.C. 2112 note, Pub. L. 108-77, 108-78, 108-2 86); 52.225-13, Restrictions on Certain Foreign Purchases (Mar 2005) (E.o.s, proclamations, and statutes administered by the Office of Foreign Assets Control of the Department of Treasury); 52.232-33, Payment by Electronic Funds Transfer-Central Contractor Registration; FAR 52.252-1 Solicitation Provisions Incorporated by Reference; FAR Clause 52.232-33, Electronic Submission of Payment Request; FAR Clause 52.204-7, Required Central Contractor Registration. Full text of provisions and clauses may be accessed electronically at the following address: http://www.arnet.gov/far. Quotes are being requested and a written solicitation will not be issued. All responsible sources should submit quotes to Rita Anderson via fax at 214-302-1416 or e-mail: rita.anderson@va.gov 12 March 2008, 2:00 PM local time.
- Record
- SN01525812-W 20080308/080306223903 (fbodaily.com)
- Source
-
FedBizOpps Link to This Notice
(may not be valid after Archive Date)
| FSG Index | This Issue's Index | Today's FBO Daily Index Page |